10.2.5 Checking and tightening screw connections
Check, as specified in the maintenance plan, that all screw connections are
tightly secured. Especially check:
the gearbox mounting screws
–
the screw plugs of bores 5, 6 and 7
–
the motor fixing screws
–
Tighten the screws of the planetary gearbox at the torque specified for the
corresponding screws in the planetary gearbox spare parts drawing in appendix
D "Technical data / Drawings" of the material number-specific operating
instructions. Observe the frame drawing of the crane or winch application
manufacturer.
10.2.6 Grease counter-bearing
Fig 5:
Counter-bearing lubricating points
11 Grease nipple
Grease the counter-bearing at the intervals specified in the maintenance
schedule. Lubricate the counter bearing via the lubricating nipple 11 on the
bearing cover / bearing housing with grease L-XBCHA3 (GB 7324 - 94) or with
FAG Arcanol MULTI3 or Klüberplex BE 31-222.
RE 79100-01-B/11.2020, MOBILEX GFT-W general operating instructions series 30, Bosch Rexroth AG
Servicing and repair
63/86