1
6.4 MONITOR PCB ADJUSTMENT
A
Notes: Flicker adjustment is needed when monitor PCB is exchanged.
- Test mode starting operation.
1)The TEST land(EPRTEST) and GND on monitor PCB are made to short-circuit.
2)It shifts to [Flicker adjustment mode] in Power ON.
3)To switch between the adjustment modes, use the MENU button.
Flicker adjustment mode
Line adjustment 1 mode
Line adjustment 2 mode
B
Dimmer parameter setting mode
Please set the CONTRAST data in [Line adjustment 1 mode] and [Line adjustment 2 mode] to [88],
and used as reference data for other adjustment items.
4)The operation in each mode is as follows.
[↑ ↓] button: Used to select a desired adjustment item in each mode
[← →] button: Used to adjust the selected item
- Adjustment Point
Monitor PCB (Side B)
C
D
E
F
152
1
2
AVH-P6500DVD/UC
2
3
3
4
4