Summary of Contents for Dell EMC PowerEdge T640 D24XR

  • Page 1 Questo manuale d’istruzione è fornito da trovaprezzi.it. Scopri tutte le offerte per Dell PowerEdge T640 D24XR o cerca il tuo prodotto tra le migliori offerte di Server Dell EMC PowerEdge T640 Installation and Service Manual Regulatory Model: E47S Series Regulatory Type: E47S001...
  • Page 2 A WARNING indicates a potential for property damage, personal injury, or death. © 2017 -2018 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.
  • Page 3: Table Of Contents

    Contents 1 Dell EMC PowerEdge T640 overview......................8 Supported configurations..............................9 Front view of the system..............................10 Status LED indicators..............................12 iDRAC Direct LED indicator codes..........................13 iDRAC Quick Sync 2 indicator codes........................14 System health and system ID indicator codes......................15 Drive indicator codes..............................16 Back view of the system..............................17...
  • Page 4 System Setup................................... 40 Viewing System Setup.............................. 40 System Setup details..............................41 System BIOS................................41 iDRAC Settings utility..............................62 Device Settings................................62 Dell Lifecycle Controller..............................62 Embedded system management..........................62 Boot Manager...................................62 Viewing Boot Manager..............................62 Boot Manager main menu............................63 One-shot BIOS boot menu............................63 System Utilities................................63...
  • Page 5 Installing a 3.5 inch drive adapter into the 3.5 inch drive carrier................77 Removing a 2.5 inch drive from a 3.5 inch drive adapter..................78 Installing a 2.5 inch drive into a 3.5 inch drive adapter..................79 Power supply units................................80 PSU specifications..............................80 Hot spare feature................................81 Removing a power supply unit blank........................81 Installing a power supply unit blank..........................82...
  • Page 6 Installing the NVDIMM-N battery.......................... 108 System memory................................109 System memory population.............................109 General memory module installation guidelines......................111 NVDIMM-N memory module installation guidelines ..................... 111 Mode-specific guidelines............................112 Removing a memory module........................... 113 Installing a memory module............................114 Processors and heat sinks..............................115 Removing a processor and heat sink module......................115 Removing the processor from the processor and heat sink module..............
  • Page 7 6 Using system diagnostics........................... 163 Dell Embedded System Diagnostics..........................163 Running the Embedded System Diagnostics from Boot Manager..............163 Running the Embedded System Diagnostics from the Dell Lifecycle Controller..........163 System diagnostic controls............................. 164 7 Getting help............................... 165 Recycling or End-of-Life service information......................165 Contacting Dell EMC..............................
  • Page 8: Dell Emc Poweredge T640 Overview

    Dell EMC PowerEdge T640 overview The Dell EMC PowerEdge T640 is a dual-socket, 5U rackable tower server that supports up to: • Two Intel Xeon Scalable processors • 24 DIMM slots (support for DDR4 RDIMM, LR-DIMM) or 12 NVDIMM-N (one DIMM per channel) are supported •...
  • Page 9: Supported Configurations

    Supported configurations Figure 1. Supported configurations of the PowerEdge T640 Dell EMC PowerEdge T640 overview...
  • Page 10: Front View Of The System

    Information tag iDRAC Quick Sync 2 wireless indicator (optional) Status LED indicators System health and system ID indicator USB port (USB 2.0-compliant) USB port (USB 3.0-compliant) iDRAC Direct (Micro-AB USB) port Optical drive (optional) Drive slots Dell EMC PowerEdge T640 overview...
  • Page 11 Information tag iDRAC Quick Sync 2 wireless indicator (optional) Status LED indicators System health and system ID indicator USB port (USB 2.0-compliant) USB port (USB 3.0-compliant) iDRAC Direct (Micro-AB USB) port Optical drive (optional) Drive slots Dell EMC PowerEdge T640 overview...
  • Page 12: Status Led Indicators

    Description Condition Corrective action PCIe indicator The indicator turns Restart the system. Update any required drivers for the PCIe card. Reinstall solid amber if a PCIe the card. If the problem persists, see Getting help. Dell EMC PowerEdge T640 overview...
  • Page 13: Idrac Direct Led Indicator Codes

    You can configure iDRAC Direct by using a USB to micro USB (type AB) cable, which you can connect to your laptop or tablet. The following table describes iDRAC Direct activity when the iDRAC Direct port is active: Dell EMC PowerEdge T640 overview...
  • Page 14: Idrac Quick Sync 2 Indicator Codes

    Restart the system. If the problem persists, see the mode. Getting help section. Blinking amber Indicates that the iDRAC Quick Sync 2 Restart the system. If the problem persists, see the hardware is not responding properly. Getting help section. Dell EMC PowerEdge T640 overview...
  • Page 15: System Health And System Id Indicator Codes

    Indicates that the system is experiencing a fault. Check the System Event Log for specific error messages. For more information about error messages, see the Event and Error Message Reference Guide for 14th Generation Dell EMC PowerEdge Servers at Dell.com/qrl. Dell EMC PowerEdge T640 overview...
  • Page 16: Drive Indicator Codes

    Flashes amber four times per second Drive failed. Flashes green slowly Drive rebuilding. Solid green Drive online. Flashes green for three seconds, amber for three seconds, and Rebuild stopped. then turns off after six seconds Dell EMC PowerEdge T640 overview...
  • Page 17: Back View Of The System

    Figure 9. Back view of the tower configuration PCIe expansion card slots System ID button/indicator VGA port Serial port iDRAC9 dedicated network port USB 2.0 port (2) PCIe expansion card slots NIC port (2) USB 3.0 port (4) Power supply unit (2) Dell EMC PowerEdge T640 overview...
  • Page 18: Nic Indicator Codes

    Each NIC on the back of the system has indicators that provide information about the activity and link status. The activity LED indicator indicates if data is flowing through the NIC, and the link LED indicator indicates the speed of the connected network. Figure 11. NIC indicator codes link LED indicator activity LED indicator Dell EMC PowerEdge T640 overview...
  • Page 19: Power Supply Unit Indicator Codes

    When the firmware of the PSU is being updated, the PSU handle blinks green. CAUTION: Do not disconnect the power cord or unplug the PSU when updating firmware. If firmware update is interrupted, the PSUs do not function. Dell EMC PowerEdge T640 overview...
  • Page 20 Power is not connected to the PSU. Blinking green When hot-plugging a PSU, the PSU indicator blinks green. This indicates that there is a PSU mismatch with respect to efficiency, feature set, health status, or supported voltage. Dell EMC PowerEdge T640 overview...
  • Page 21: Locating The Service Tag Of Your System

    Express Service Code and Service Tag. Alternatively, the information may be on a sticker on the chassis of the system. The mini Enterprise Service Tag (EST) is found on the back of the system. This information is used by Dell to route support calls to the appropriate personnel.
  • Page 22: System Information Label

    System information label PowerEdge T640 – system information label Figure 15. LED behavior Dell EMC PowerEdge T640 overview...
  • Page 23 Figure 16. Configuration and layout Dell EMC PowerEdge T640 overview...
  • Page 24 Dell EMC PowerEdge T640 overview Figure 17. Electrical overview...
  • Page 25 Figure 18. Memory information Dell EMC PowerEdge T640 overview...
  • Page 26 Dell EMC PowerEdge T640 overview...
  • Page 27: Technical Specifications

    Technical specifications The technical and environmental specifications of your system are outlined in this section. Topics: • Chassis dimensions • Chassis weight • Processor specifications • Supported operating systems • Cooling fan specifications • PSU specifications • System battery specifications •...
  • Page 28: Chassis Dimensions

    Maximum weight (with all hard drives/SSDs) 32 x 2.5-inch 42.36 Kg (93.38 lb) 18 x 3.5-inch 49.65 Kg (109.45 lb) Processor specifications The Dell EMC PowerEdge T640 system supports up to two Intel Xeon Scalable processors, up to 28 cores per processor. Technical specifications...
  • Page 29: Supported Operating Systems

    For information on the restriction for fresh air condition, see the Expanded operating temperature restrictions topic in the Technical Specification section. PSU specifications The Dell EMC PowerEdge T640 system supports up to two AC or DC redundant power supply units (PSUs). Technical specifications...
  • Page 30: System Battery Specifications

    The Dell EMC PowerEdge T640 system supports CR 2032 3.0-V lithium coin cell system battery. Expansion bus specifications The Dell EMC PowerEdge T640 system supports PCI express (PCIe) generation 3 and 2 expansion cards. The following table describes the supported expansion cards: Table 12.
  • Page 31: Memory Specifications

    The expansion card slots are not hot-swappable. Memory specifications The Dell EMC PowerEdge T640 system supports up to twenty four 288-pins RDIMMS/LRDIMMS or twelve RDIMMS/LRDIMMS and twelve NVDIMM-Ns with speeds of 2667 MT/s, 2400 MT/s and 2133 MT/s with support for memory optimized operation.
  • Page 32: Optical Drive

    The LOM (Broadcom 57416) is compatible with 10GBASE-T IEEE 802.3an and 1000 BASE-T IEEE 802.3ab. VGA ports The Video Graphic Array (VGA) port enables you to connect the system to a VGA display. The Dell EMC PowerEdge T640 system supports two 15-pin VGA ports on the front and back panels.
  • Page 33: Serial Connector

    Serial connector The Dell EMC PowerEdge T640 system supports one serial connector on the back panel, which is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant. Internal Dual SD Module with vFlash card The Dell EMC PowerEdge T640 system supports Internal Dual SD module (IDSDM) and vFlash card. In 14th generation of PowerEdge servers, IDSDM and vFlash card are combined into a single card module, and are available in anyone of these configurations: •...
  • Page 34 Table 16. Temperature specifications Temperature Specifications Storage –40°C to 65°C (–40°F to 149°F) Continuous operation (for altitude less than 950 m or 3117 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment. Fresh air For information about fresh air, see Expanded Operating Temperature section.
  • Page 35: Standard Operating Temperature

    Operating temperature de-rating Specifications 40°C to 45°C (104°F to 113°F) Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft). Standard operating temperature Table 22. Standard operating temperature specifications Standard operating temperature Specifications Continuous operation (for altitude less than 950 m or 3117 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
  • Page 36: Particulate And Gaseous Contamination Specifications

    • Non-Dell qualified peripheral cards are not supported. • Peripheral cards consuming greater than 25 W are not supported. • 128 GB LRDIMM is supported. • NVDIMM is not supported. • Mellanox 100 GB, Mellanox Navi DP/SP, Intel FortPond Solarflare Nova, Solarflare Sunspot are not supported.
  • Page 37: Initial System Setup And Configuration

    Options to set up iDRAC IP address iDRAC configuration The Integrated Dell Remote Access Controller (iDRAC) is designed to make system administrators more productive and improve the overall availability of Dell systems. iDRAC alerts administrators about system issues, helps them perform remote system management, and reduces the need for physical access to the system.
  • Page 38: Log In To Idrac

    The license files are enabled on the sleds through iDRAC. For more information about drivers, documentation, and white papers on the Intel® QAT, see https://01.org/intel-quickassist-technology. For more information about logging in to the iDRAC and iDRAC licenses, see the latest Integrated Dell Remote Access Controller User's Guide at Dell.com/poweredgemanuals.
  • Page 39: Downloading Drivers And Firmware

    Using iDRAC virtual media Dell.com/idracmanuals Downloading drivers and firmware Dell recommends that you download and install the latest BIOS, drivers, and systems management firmware on your system. Prerequisite Ensure that you clear the web browser cache before downloading the drivers and firmware.
  • Page 40: Pre-Operating System Management Applications

    You can manage basic settings and features of a system without booting to the operating system by using the system firmware. Topics: • Options to manage the pre-operating system applications • System Setup • Dell Lifecycle Controller • Boot Manager • PXE boot Options to manage the pre-operating system applications Your system has the following options to manage the pre-operating system applications: •...
  • Page 41: System Setup Details

    The iDRAC settings utility is an interface to set up and configure the iDRAC parameters by using UEFI (Unified Extensible Firmware Interface). You can enable or disable various iDRAC parameters by using the iDRAC settings utility. For more information about this utility, see Integrated Dell Remote Access Controller User’s Guide at Dell.com/poweredgemanuals.
  • Page 42 Option Description Network Settings Specifies options to manage the UEFI network settings and boot protocols. Legacy network settings are managed from the Device Settings menu. Integrated Devices Specifies options to manage integrated device controllers and ports, specifies related features and options. Serial Specifies options to manage the serial ports, its related features and options.
  • Page 43 Specifies the memory operating mode. The options available are Optimizer Mode, Single Rank Spare Mode, Multi Mode Rank Spare Mode, Mirror Mode, and Dell Fault Resilient Mode. This option is set to Optimizer Mode by default. Pre-operating system management applications...
  • Page 44 NOTE: The Dell Fault Resilient Mode option establishes an area of memory that is fault resilient. This mode can be used by an operating system that supports the feature to load critical applications or enables the operating system kernel to maximize system availability.
  • Page 45 Option Description Hardware Enables or disables the hardware prefetcher. This option is set to Enabled by default. Prefetcher DCU Streamer Enables or disables the Data Cache Unit (DCU) streamer prefetcher. This option is set to Enabled by default. Prefetcher DCU IP Prefetcher Enables or disables the Data Cache Unit (DCU) IP prefetcher.
  • Page 46 Viewing SATA Settings To view the SATA Settings screen, perform the following steps: Turn on, or restart your system. Press F2 immediately after you see the following message: F2 = System Setup NOTE: If your operating system begins to load before you press F2, wait for the system to finish booting, and then restart your system and try again.
  • Page 47 Option Description Option Description Model Specifies the drive model of the selected device. Drive Type Specifies the type of drive attached to the SATA port. Capacity Specifies the total capacity of the hard drive. This field is undefined for removable media devices such as optical drives.
  • Page 48 Option Description Port H Sets the drive type of the selected device. For the Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI or RAID mode, BIOS support is always enabled. Option Description Model...
  • Page 49 NOTE: You must use only the UEFI boot mode in order to boot from NVMe drives. • BIOS: The BIOS Boot Mode is the legacy boot mode. It is maintained for backward compatibility. Viewing Boot Settings To view the Boot Settings screen, perform the following steps: Turn on, or restart your system.
  • Page 50 UEFI and can only be installed from the BIOS boot mode. NOTE: For the latest information about supported operating systems, go to Dell.com/ossupport Changing boot order About this task You may have to change the boot order if you want to boot from a USB key. You may have to change the boot order if you want to boot from a USB key or an optical drive.
  • Page 51 On the System BIOS screen, click Network Settings. Network Settings screen details The Network Settings screen details are explained as follows: Option Description PXE Device n (n = 1 Enables or disables the device. When enabled, a UEFI PXE boot option is created for the device. to 4) PXE Device n Enables you to control the configuration of the PXE device.
  • Page 52 Integrated Devices You can use the Integrated Devices screen to view and configure the settings of all integrated devices including the video controller, integrated RAID controller, and the USB ports. Viewing Integrated Devices To view the Integrated Devices screen, perform the following steps: Turn on, or restart your system.
  • Page 53 Option Description NOTE: When there are multiple add-in graphic cards installed in the system, the first card discovered during PCI enumeration is selected as the primary video. You might have to re-arrange the cards in the slots in order to control which card is the primary video. Current State of Displays the current state of the embedded video controller.
  • Page 54 Option Description Option Description x4 or x8 Bifurcation Slot 7 Bifurcation x16, x4, x8, x4 x4 x8 or x8 x4 x4 Bifurcation Slot 8 Bifurcation Serial Communication You can use the Serial Communication screen to view the properties of the serial communication port. Viewing Serial Communication To view the Serial Communication screen, perform the following steps: Turn on, or restart your system.
  • Page 55 You can only change the rest of the options if the mode is set to Custom.This option is set to Performance Per Watt Optimized (DAPC) by default. DAPC is Dell Active Power Controller. NOTE: All the parameters on the system profile setting screen are available only when the System Profile option is set to Custom.
  • Page 56 Option Description Memory Refresh Sets the memory refresh rate to either 1x or 2x. This option is set to 1x by default. Rate Uncore Frequency Enables you to select the Processor Uncore Frequency option. Dynamic mode enables the processor to optimize power resources across the cores and uncore during runtime. The optimization of the uncore frequency to either save power or optimize performance is influenced by the setting of the Energy Efficiency Policy option.
  • Page 57 System Security Settings details The System Security Settings screen details are explained as follows: Option Description Intel(R) AES-NI Improves the speed of applications by performing encryption and decryption by using the Advanced Encryption Standard Instruction Set (AES-NI). This option is set to Enabled by default. System Password Sets the system password.
  • Page 58 Option Description Options Description User Mode In User Mode, PK must be installed, and BIOS performs signature verification on programmatic attempts to update policy objects. The BIOS allows unauthenticated programmatic transitions between modes. Audit Mode In Audit mode, PK is not present. The BIOS does not authenticate programmatic updates to the policy objects, and transitions between modes.
  • Page 59 A message prompts you to reenter the setup password. Reenter the setup password, and click OK. Press Esc to return to the System BIOS screen. Press Esc again. A message prompts you to save the changes. NOTE: Password protection does not take effect until the system reboots. Using your system password to secure your system About this task If you have assigned a setup password, the system accepts your setup password as an alternate system password.
  • Page 60 If you do not type the correct password in three attempts, the system displays the following message: Invalid Password! Number of unsuccessful password attempts: <x> System Halted! Must power down. Password Invalid. Number of unsuccessful password attempts: <x> Maximum number of password attempts exceeded.System halted.
  • Page 61 UEFI boot mode. You cannot set the option to Enabled if UEFI Secure Boot mode is enabled. This option is set to Disabled by default. Dell Wyse P25/P45 Enables or disables the Dell Wyse P25/P45 BIOS Access. This option is set to Enabled by default. BIOS Access Power Cycle Enables or disables the Power Cycle Request.
  • Page 62: Idrac Settings Utility

    Dell Lifecycle Controller Dell Lifecycle Controller (LC) provides advanced embedded systems management capabilities including system deployment, configuration, update, maintenance, and diagnosis. LC is delivered as part of the iDRAC out-of-band solution and Dell system embedded Unified Extensible Firmware Interface (UEFI) applications.
  • Page 63: Boot Manager Main Menu

    Launch System Enables you to access System Setup. Setup Launch Lifecycle Exits the Boot Manager and invokes the Dell Lifecycle Controller program. Controller System Utilities Enables you to launch System Utilities menu such as System Diagnostics and UEFI shell. One-shot BIOS boot menu One-shot BIOS boot menu enables you to select a boot device to boot from.
  • Page 64: Installing And Removing System Components

    Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
  • Page 65: Removing The Front Bezel

    Removing the front bezel Prerequisite Follow the safety guidelines listed in Safety instructions. Steps Unlock the bezel. Press the blue release latch at the top of the bezel to release the bezel from the system. Pull the top end of the bezel away from the system. Unhook the bezel tabs from the slots at the bottom of the system, and lift the bezel away.
  • Page 66: System Feet

    Figure 22. Installing the front bezel System feet Removing the system feet Prerequisites NOTE: It is recommended that you remove the system feet only when you are converting the system from the tower mode to the rack mode, or when you are replacing the system feet with the wheel assembly. Follow the safety guidelines listed in Safety instructions.
  • Page 67: Installing The System Feet

    Figure 23. Removing the system feet Next step Install the system feet install the castor wheels. Installing the system feet Prerequisites CAUTION: Install the feet on a stand-alone tower system to provide stability to the system. An unstable system might tip over and cause injury to the user or damage to the system.
  • Page 68: Caster Wheels - Optional

    Figure 24. Installing the system feet Next steps Place the system upright on a flat, stable surface, and rotate the system feet outward. Follow the procedure listed in After working inside your system. Caster wheels – optional Removing caster wheels Prerequisites Follow the safety guidelines listed in Safety...
  • Page 69: Installing Caster Wheels

    Figure 25. Removing caster wheels Next step Install the caster wheels the system feet, as applicable. Installing caster wheels Prerequisites Follow the safety guidelines listed in Safety instructions. Place the system on its side on a flat, stable surface. If installed, remove the system feet.
  • Page 70: Drives

    Figure 26. Installing caster wheels Next step Follow the procedure listed in Before working inside your system. Drives Removing a drive blank The procedure for removing 2.5 inch and 3.5 inch drive blanks is identical. Prerequisites Follow the safety guidelines listed in Safety instructions.
  • Page 71: Installing A Drive Blank

    Figure 27. Removing a drive blank Next step Install a drive drive blank. Installing a drive blank The procedure for installing 2.5 inch and 3.5 inch drive blanks is identical. Prerequisites Follow the safety guidelines listed in Safety instructions. If installed, remove the front bezel.
  • Page 72: Removing A Drive Carrier

    Figure 28. Installing a drive blank Next step If removed, install the front bezel. Removing a drive carrier Prerequisites Follow the safety guidelines listed in Safety instructions. If applicable, remove the front bezel Using the management software, prepare the drive for removal. If the drive is online, the green activity or fault indicator flashes while the drive is turning off.
  • Page 73: Installing A Drive Carrier

    Figure 29. Removing a drive carrier Next steps Installing a drive carrier. If you are not replacing the drive immediately, insert a drive blank in the empty drive slot to maintain proper system cooling. Installing a drive carrier Prerequisites CAUTION: Before attempting to remove or install a drive while the system is running, see the documentation for the storage controller card to ensure that the host adapter is configured correctly to support drive removal and insertion.
  • Page 74: Removing The Drive From The Drive Carrier

    Figure 30. Installing a drive carrier Next step If removed, install the front bezel. Removing the drive from the drive carrier Prerequisite Follow the safety guidelines listed in Safety instructions. CAUTION: Mixing drives from previous generations of PowerEdge servers is not supported. Steps Using a Phillips #1 screwdriver, remove the screws from the slide rails on the drive carrier.
  • Page 75: Installing A Drive Into The Drive Carrier

    Figure 31. Removing the drive from the drive carrier Next step Installing the drive into the drive carrier. Installing a drive into the drive carrier Prerequisites Follow the safety guidelines listed in Safety instructions. CAUTION: Mixing drive carriers from other generations of PowerEdge servers is not supported. NOTE: When installing a drive into the drive carrier, ensure that the screws are torqued to 4 in-lbs.
  • Page 76: Removing A 3.5 Inch Drive Adapter From A 3.5 Inch Drive Carrier

    Figure 32. Installing a drive into the drive carrier Removing a 3.5 inch drive adapter from a 3.5 inch drive carrier Prerequisites Follow the safety guidelines listed in Safety instructions. If installed, remove the front bezel. Remove the drive carrier. Steps Using a Phillips #1 screwdriver, remove the screws from the rails on the drive carrier.
  • Page 77: Installing A 3.5 Inch Drive Adapter Into The 3.5 Inch Drive Carrier

    Figure 33. Removing a 3.5 inch drive adapter from a 3.5 inch drive carrier Next step Install the 3.5 inch drive adapter into the 3.5 inch drive carrier Installing a 3.5 inch drive adapter into the 3.5 inch drive carrier Prerequisites Follow the safety guidelines listed in Safety...
  • Page 78: Removing A 2.5 Inch Drive From A 3.5 Inch Drive Adapter

    Figure 34. Installing a 3.5 inch drive adapter into the 3.5 inch drive carrier Next steps Install the drive carrier. If removed, install the front bezel. Removing a 2.5 inch drive from a 3.5 inch drive adapter Prerequisites Follow the safety guidelines listed in Safety instructions.
  • Page 79: Installing A 2.5 Inch Drive Into A 3.5 Inch Drive Adapter

    Figure 35. Removing a 2.5 inch drive from a 3.5 inch drive adapter Next step Install a 2.5 inch drive into a 3.5 inch drive adapter. Installing a 2.5 inch drive into a 3.5 inch drive adapter Prerequisites Follow the safety guidelines listed in Safety instructions.
  • Page 80: Power Supply Units

    Figure 36. Installing a 2.5 inch drive into a 3.5 inch drive adapter Next step Install the 3.5 inch drive adapter into the 3.5 inch hot swappable drive carrier. Power supply units PSU specifications The power supply unit (PSU) is an internal hardware component which supplies power to the components in the system. Your system supports one of the following: •...
  • Page 81: Hot Spare Feature

    If the load on the active PSU falls below 20 percent of PSU rated power wattage, then the redundant PSU is switched to the sleep state. You can configure the hot spare feature by using the iDRAC settings. For more information, see the iDRAC User’s Guide available at Dell.com/idracmanuals. Removing a power supply unit blank Prerequisite...
  • Page 82: Installing A Power Supply Unit Blank

    Installing a power supply unit blank Prerequisite Follow the safety guidelines listed in Safety instructions. NOTE: Install the power supply unit (PSU) blank only in the second PSU bay. Step Align the PSU blank with the PSU slot and push it into the PSU slot until it clicks into place. Figure 38.
  • Page 83: Installing A Ac Power Supply Unit

    Figure 39. Removing a power supply unit Next step Install the AC PSU. Installing a AC power supply unit Prerequisites Follow the safety guidelines listed in Safety instructions. For systems that support redundant PSU, ensure that both the PSUs are of the same type and have the same maximum output power.
  • Page 84: Removing A Dc Power Supply Unit

    DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not covered by your warranty.
  • Page 85: Installing Dc Power Supply Unit

    DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not covered by your warranty.
  • Page 86: System Cover

    Kit contents • Dell part number 6RYJ9 terminal block or equivalent (1) • #6-32 nut equipped with lock washer (1) Required tools Wire-stripper pliers capable of removing insulation from size 10 AWG solid or stranded, insulated copper wire. NOTE: Use alpha wire part number 3080 or equivalent (65/30 stranding).
  • Page 87: Installing The System Cover

    Figure 41. Removing the system cover Next step Install the system cover. Installing the system cover Prerequisite NOTE: Ensure that all internal cables are connected and placed out of the way and no tools or extra parts are left inside the system.
  • Page 88: Inside The System

    Figure 42. Installing the system cover Next steps Place the system upright on its feet on a flat and stable surface. If removed, install the front bezel. Reconnect the peripherals and connect the system to the electrical outlet. Turn on the system, including all attached peripherals. Inside the system NOTE: Components that are hot swappable are marked orange and touch points on the components are marked blue.
  • Page 89: Air Shroud

    Release latch Drive cage Hot-swappable fans (middle fans) GPU card holder Internal PERC PCIe card holder PCIe slots Left external fan Right external fan CPU2 socket CPU1 Backplane Air shroud Removing the optional GPU air shrouds Prerequisites CAUTION: Never operate your system with the air shroud removed. The system may get overheated quickly, resulting in shutdown of the system and loss of data.
  • Page 90: Installing The Optional Gpu Air Shrouds

    Figure 43. Removing the optional GPU air shrouds Next step Install the optional GPU air shrouds. Installing the optional GPU air shrouds Prerequisite Follow the safety guidelines listed in Safety instructions. Steps Align the tabs on the GPU air shroud with the securing slots on the chassis. Lower the GPU air shroud into the chassis until it is firmly seated.
  • Page 91: Removing The Air Shroud

    Figure 44. Installing the optional GPU air shrouds Next step Follow the procedure listed in After working inside your system. Removing the air shroud Prerequisites CAUTION: Never operate your system with the air shroud removed. The system may get overheated quickly, resulting in shutdown of the system and loss of data.
  • Page 92: Installing The Air Shroud

    Figure 45. Removing the air shroud Next step Install the air shroud. Installing the air shroud Prerequisites Follow the safety guidelines listed in Safety instructions. If applicable, route the cables inside the system along the chassis wall and secure the cables by using the cable-securing bracket. Steps Align the tabs on the air shroud with the securing slots on the chassis.
  • Page 93: Cooling Fans

    Figure 46. Installing the air shroud Next step Follow the procedure listed in After working inside your system. Cooling fans Cooling fan specifications The cooling fans are integrated into the system to dissipate the heat generated by the functioning of the system. These fans provide cooling for the processors, expansion cards, and memory modules.
  • Page 94: Cooling Fan Matrix

    • Mellanox CX4 SP 100 Gb NIC (6W1HY) • Mellanox DP 40 Gb QSFP NIC (C8Y42) • Intel QP 10 Gb Base-T NIC (K5V44) • Solarflare Sunspot DP 10Gb NIC (NPHCM) • Solarflare Nova DP 10Gb NIC (WY7T5) • Qlogic DP 10Gb V1 NIC (VCXN5) Listed below are the restrictions for fan redundancy: •...
  • Page 95: Installing A Middle Or Rear Cooling Fan

    Figure 47. Removing a middle cooling fan Next step Installing a middle or rear cooling fan. Installing a middle or rear cooling fan The procedure for installing a standard and a high performance fans is identical. Prerequisites WARNING: Opening or removing the system cover when the system is on may expose you to a risk of electric shock. Exercise utmost care while removing or installing cooling fans.
  • Page 96: Removing The Right External Fan

    Figure 48. Installing a middle cooling fan Next step Follow the procedure listed in After working inside your system. Removing the right external fan Prerequisites WARNING: Opening or removing the system cover when the system is on may expose you to a risk of electric shock. Exercise utmost care while removing or installing cooling fans.
  • Page 97: Installing The Right External Fan

    Figure 49. Removing the right external fan Next step Installing the right external fan. Installing the right external fan Prerequisite NOTE: The procedure to install the left external fan is similar to installing the right rear fan. Follow the safety guidelines listed in Safety instructions.
  • Page 98: Cooling Fan (Middle Fan) Assembly

    Install the GPU air shrouds. Follow the procedure listed in After working inside your system. Cooling fan (middle fan) assembly Removing the middle cooling fan assembly Prerequisites Follow the safety guidelines listed in Safety instructions. Follow the procedure listed in Before working inside your system.
  • Page 99: Flex Bays

    CAUTION: Ensure that the cables inside the system are correctly installed and retained by the cable retention bracket before installing the cooling fan assembly. Incorrectly installed cables may get damaged. Steps Align the guide rails on the cooling fan assembly with the standoffs on the system. Lower the cooling fan assembly into the system until the cooling fan connectors engage with the connectors on the system board.
  • Page 100: Installing A Nvme Drive Bay Or Flex Bay

    Steps Using the Phillips #2 screwdriver, remove the two screws that secure the NVMe drive bay to the system. Push the release latch down and slide the NVMe drive bay out of the system. Figure 53. Removing a NVMe drive bay or flex bay Next step Installing the NVMe drive bay or flex bay.
  • Page 101: Optical Drives And Tape Drives

    Figure 54. Installing a NVMe drive bay or flex bay Next steps Install the backplane to the NVMe drive bay or flex bay. Connect the slim optical drive and the back plane cables. Follow the procedure listed in After working inside your system.
  • Page 102: Removing The Optical Or Tape Drive Blank

    Removing the optical or tape drive blank Prerequisites Follow the safety guidelines listed in Safety instructions. Follow the procedure listed in Before working inside your system. If installed, remove the front bezel. Steps To remove the drive blank, slide the release latch down to release the drive blank. Push the drive blank to slide it out of the drive bay.
  • Page 103: Removing The Optical Drive Cage Or Tape Drive

    Steps Align the guide on the drive blank with the slot on drive bay. Slide the drive into the slot until the latch snaps into place. Figure 56. Installing the optical or tape drive blank Next steps If removed, install the front bezel.
  • Page 104: Installing The Optical Drive Cage Or Tape Drive

    Figure 57. Removing the optical drive cage or tape drive Next step Install the optical drive cage or tape drive. Installing the optical drive cage or tape drive Prerequisite NOTE: The procedure to install the optical drive cage is the same as installing the tape drive. Follow the safety guidelines listed in Safety instructions.
  • Page 105: Removing The Slim Optical Drive

    Figure 58. Installing the optical drive cage or tape drive Next steps If removed, install the front bezel. Follow the procedure listed in After working inside your system. Removing the slim optical drive The procedure to remove the slim optical drive blank is similar to removing the slim optical drive. Prerequisites Follow the safety guidelines listed in Safety...
  • Page 106: Installing The Slim Optical Drive

    Figure 59. Removing the slim optical drive blank Next step Install the slim optical drive or the optical drive blank. Installing the slim optical drive The procedure to install the optical drive blank is similar to installing the slim optical drive. Prerequisite Follow the safety guidelines listed in Safety...
  • Page 107: Nvdimm-N Battery

    Figure 60. Installing the slim optical drive blank Next steps Install the optical drive cage. Follow the procedure listed in After working inside your system. NVDIMM-N battery Removing the NVDIMM-N battery Prerequisites Follow the safety guidelines listed in Safety instructions. Follow the procedure listed in Before working inside your system.
  • Page 108: Installing The Nvdimm-N Battery

    Figure 61. Removing the NVDIMM-N battery Next step Install the NVDIMM-N battery. Installing the NVDIMM-N battery Prerequisite CAUTION: To avoid damage to the battery connector, you must firmly support the connector while installing or removing a battery. Follow the safety guidelines listed in Safety instructions.
  • Page 109: System Memory

    Figure 62. Installing the NVDIMM-N battery Next steps Install the NVDIMM-N battery cage. Follow the procedure listed in After working inside your system. System memory System memory population The system supports DDR4 registered DIMMs (RDIMMs), load reduced DIMMs (LRDIMMs). System memory holds the instructions that are executed by the processor.
  • Page 110 Figure 63. System memory view Table 31. Memory channels Processor Channel 0 Channel 1 Channel 2 Channel 3 Processor 1 Slots A1, A5, and A9 Slots A2, A6, and A10 Slots A3, A7, and A11 Slots A4, A8, and A12 Processor 2 Slots B1, B5, and B9 Slots B2, B6, and B10 Slots B3, B7, and B11...
  • Page 111: General Memory Module Installation Guidelines

    DIMM Type DIMMs Populated/ Operating Frequency (in Maximum DIMM Rank/Channel Voltage Channel MT/s) LRDIMM 2666, 2400, 2133 Quad rank 1.2 V 2666, 2400, 2133 Quad rank NVDIMM population rules • Maximum of one NVDIMM per channel. • Maximum of six NVDIMMs per processor •...
  • Page 112: Mode-Specific Guidelines

    • Maximum of 12 NVDIMM-Ns can be installed in a system. For more information on the supported NVDIMM-N configurations, see the NVDIMM-N User Guide at Dell.com/poweredgemanuals. Mode-specific guidelines Six memory channels are allocated to each processor. The configurations allowed depend on the memory mode selected.
  • Page 113: Removing A Memory Module

    Table 34. Memory population rules Processor Configuration Memory population Memory population information Single CPU Optimizer (Independent channel) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12 Populate in this order, odd amount population order allowed. Mirror population order {1, 2, 3, 4, 5, 6}, {7, 8, 9, 10, 11, 12} Mirroring is supported with 6 or 12 DIMM slots per CPU.
  • Page 114: Installing A Memory Module

    CAUTION: Handle each memory module only by the card edges, ensuring not to touch the middle of the memory module or metallic contacts. Push the ejectors outward on both ends of the memory module socket to release the memory module from the socket. Lift and remove the memory module from the system.
  • Page 115: Processors And Heat Sinks

    Press the memory module with your thumbs until the socket levers firmly click into place. Figure 65. Installing a memory module For more information on the memory slot locations, see the System memory population topic. Next steps Install the air shroud. Follow the procedure listed in After working inside your system.
  • Page 116: Removing The Processor From The Processor And Heat Sink Module

    Return to the first screw and loosen it completely. Pushing both blue retention clips simultaneously, lift the processor and heat sink module (PHM). Set the PHM aside with the processor side facing up. Figure 66. Removing the processor and heat sink module Next step Install the PHM.
  • Page 117 Follow the safety guidelines listed in Safety instructions. Follow the procedure listed in Before working inside your system. Remove the air shroud. Remove the processor and heat sink module. Steps Place the heat sink with the processor side facing up. Insert a flat blade screwdriver into the release slot marked with a yellow label.
  • Page 118: Installing The Processor Into A Processor And Heat Sink Module

    Figure 68. Removing the processor bracket Next step Install the processor into the processor and heat sink module. Installing the processor into a processor and heat sink module Prerequisite Follow the safety guidelines listed in Safety instructions. Steps Place the processor in the processor tray. NOTE: Ensure that the pin 1 indicator on the processor tray is aligned with the pin 1 indicator on the processor.
  • Page 119 Figure 69. Installing the processor bracket If you are using an existing heat sink, remove the thermal grease from the heat sink by using a clean lint-free cloth. Use the thermal grease syringe included with your processor kit to apply the grease in a quadrilateral design on the top of the processor.
  • Page 120 Place the heat sink on the processor and push down on the base of the heat sink until the bracket locks onto the heat sink. NOTE: • Ensure that the two guide pin holes on the bracket match the guide holes on the heat sink. •...
  • Page 121: Installing A Processor And Heat Sink Module

    Installing a processor and heat sink module Prerequisites CAUTION: Never remove the heat sink from a processor unless you intend to replace the processor. The heat sink is necessary to maintain proper thermal conditions. Follow the safety guidelines listed in Safety instructions.
  • Page 122: Expansion Card Holder

    Figure 72. Installing a processor and heat sink module Next step Follow the procedure listed in After working inside your system. Expansion card holder Removing the expansion card holder Prerequisites Follow the safety guidelines listed in Safety instructions. Follow the procedure listed in Before working inside your system.
  • Page 123: Installing The Expansion Card Holder

    Steps Press the tab and slide the expansion card holder up. Lift the expansion card holder away from the chassis. Figure 73. Removing the expansion card holder Next step Install the expansion card holder. Installing the expansion card holder Prerequisite Follow the safety guidelines listed in Safety instructions.
  • Page 124: Gpu Card Holder (Optional)

    GPU card holder (optional) GPU card restriction The restrictions for GPU card is listed below: • Requires cooling fan assembly (middle high-performance fans) and 1 or 2 external fans. • If a GPU is installed in slot 1, 3, the right external fan is required. If a GPU is installed in slot 6, 8, both external fans are required. •...
  • Page 125: Installing The Optional Gpu Card Holder

    Figure 75. Removing the GPU card holder Next step Install the optional GPU card holder. Installing the optional GPU card holder Prerequisite Follow the safety guidelines listed in Safety instructions. Step Align the GPU card holder with the slots and the guide pin on the system, and push the GPU card holder down until it locks in place. Installing and removing system components...
  • Page 126: Expansion Cards

    Figure 76. Installing the optional GPU card holder Next steps Install the air shroud. Follow the procedure listed in After working inside your system. Expansion cards Expansion card installation guidelines The following table describes the supported expansion cards: Table 35. Supported PCI express generation 3 expansion cards PCIe Slot Processor Connection Height...
  • Page 127: Expansion Card Slot Priority

    Card Card Type Slot Priority Maximum Priority Allowed 1 or 2 CPU, no GPU (no Dell PowerEdge Express Flash (PCIe SSD) Bridge 1, 3 external fan) RAID (H330), RAID (H730P) RAID (H740P) 0, 1 RAID (H840), BOSS 4, 7, 1, 6, 8...
  • Page 128 7, 8, 6, 4 HBA330 0, 1, 3 PCIe SSD 1, 3, 7, 8, 6, 4 2 CPU, 2 External fans Dell PowerEdge Express Flash (PCIe SSD) Bridge 1, 3 GPUs 3, 6, 8, 1 RAID (H330), RAID (H730) RAID (H740)
  • Page 129: Removing A Expansion Card

    Removing a expansion card Prerequisites Follow the safety guidelines listed in Safety instructions. Follow the procedure listed in Before working inside your system. Remove the air shroud. Remove the expansion card holder. Steps If installed, disconnect the data cables from the PERC card and/or the power cables from the GPU card. Press the expansion card latch and push down the latch to open it.
  • Page 130: Installing An Expansion Card

    Figure 78. Installing the filler bracket Next step Install an expansion card. Installing an expansion card Prerequisites Follow the safety guidelines listed in Safety instructions. Remove the air shroud. Remove the expansion card holder. Steps Unpack the expansion card and prepare it for installation. For instructions, see the documentation accompanying the card.
  • Page 131: M.2 Ssd Module

    Figure 79. Removing the filler bracket Figure 80. Installing an expansion card Next steps Install the expansion card holder. Follow the procedure listed in After working inside your system. M.2 SSD module Removing the M.2 SSD module Prerequisites Follow the safety guidelines listed in Safety instructions.
  • Page 132: Installing The M.2 Ssd Module

    NOTE: Removing the BOSS card is similar to the procedure for removing an expansion card riser. Steps Loosen the screws and lift the retention straps that secure the M.2 SSD module on the BOSS card. Pull the M.2 SSD module away from the BOSS card. Figure 81.
  • Page 133: Optional Idsdm Or Vflash Module

    Figure 82. Installing the M.2 SSD module Next steps Install the BOSS card. NOTE: Installing the BOSS card is similar to installing the expansion card riser. Install the air shroud. Follow the procedure listed in After working inside your system. Optional IDSDM or vFlash module Removing the MicroSD card Prerequisites...
  • Page 134: Installing The Microsd Card

    Installing the MicroSD card Prerequisites Follow the safety guidelines listed in Safety instructions. NOTE: To use an MicroSD card with your system, ensure that the Internal SD Card Port is enabled in System Setup. NOTE: If reinstalling, ensure that you install the MicroSD cards into the same slots based on the labels you had marked on the cards during removal.
  • Page 135: Installing Optional Idsdm Or Vflash Module

    Figure 83. Removing the optional IDSDM/vFlash module NOTE: There are two dip switches on the IDSDM/vFlash module for write-protection. Next step Install the optional IDSDM/vFlash card. Installing optional IDSDM or vFlash module Prerequisite Follow the safety guidelines listed in Safety instructions.
  • Page 136: Backplane

    8 x 3.5 inch SAS/SATA backplane • 18 x 3.5 inch SAS/SATA backplane • 8 x 2.5 inch Dell PowerEdge Express Flash (NVMe) backplane • 16 x 2.5 inch SAS/SATA backplane with the optional additional backplanes below: – 8 x 2.5 inch NVMe backplane –...
  • Page 137 Figure 85. 16 x 2.5 SAS/SATA backplane backplane power connector A [J_BP_PWR_A] backplane power connector B [J_BP_PWR_B] optical drive power connector [J_ODD_PWR] backplane signal connector [J_BP_SIG] SAS A0 connector [J_SAS_A0] SAS B0 connector [J_SAS_B0] I2C connector Figure 86. 8 x 2.5 NVMe backplane backplane power connector [J_BP_PWR1] PCIe B0 connector [J_PCIE_B0] PCIe A0 connector [J_PCIE_A0]...
  • Page 138: Removing A Backplane

    Figure 87. 18 x 3.5 SAS/SATA backplane backplane power connector A [J_BP_PWR_A1] controller backplane power connector B [J_BP_PWR_B1] optical drive power connector [J_ODD1] I2C connector backplane signal connector [J_BP_SIG1] SAS A0_B0 connector [J_SAS_A0_B0] Figure 88. 8 x 3.5 SAS/SATA backplane optical drive power connector [J_ODD1] backplane power connector [J_BP_PWR_A] SAS A0 connector [J_BP_SIG]...
  • Page 139: Installing A Backplane

    CAUTION: You must note the number of each hard drive and temporarily label them before removal so that you can replace them in the same locations. Follow the safety guidelines listed in Safety instructions. Follow the procedure listed in Before working inside your system.
  • Page 140 Figure 90. Installing a backplane Next steps If removed, install the middle cooling fan assembly. Install the drives into their original slots. Follow the procedure listed in After working inside your system. Installing and removing system components...
  • Page 141: Backplane Cabling

    Backplane cabling Figure 91. 2.5 inch x32 SAS/SATA to internal PERC and PERC adapter 2.5 inch x 16 backplane (flex bay) SAS cable (BP: J_EXP_A1 to PERC adapter) SAS cable (BP: J_EXP_B1 to PERC adapter) internal PERC card PERC adapter SAS cable (BP: J_SAS_A0 to internal PERC card) SAS cable (BP: J_SAS_B0 to internal PERC card) 2.5 inch x 16 backplane...
  • Page 142 Figure 92. 2.5 inch x16 SAS/SATA to internal PERC with 2.5 inch x8 NVMe to PCIe bridge 2.5 inch x8 NVMe backplane NVMe cable (BP: J_PCIE_B0 to PCIe bridge: J6) NVMe cable (BP: J_PCIE_A0 to PCIe bridge: J5) NVMe cable (BP: J_PCIE_B1 to PCIe bridge: J6) NVMe cable (BP: J_PCIE_A1 to PCIe bridge: J5) internal PERC card PCIe bridge on Slot 1...
  • Page 143 Figure 93. 3.5 inch x8 SAS/SATA to internal PERC SAS cable (BP: SAS_A0 to internal PERC card: SAS_A) SAS cable (BP: SAS_B0 to internal PERC card: SAS_B) internal PERC 3.5 inch x8 SAS/SATA backplane Installing and removing system components...
  • Page 144 Figure 94. 3.5 inch x8 onboard SAS controller SAS cable (BP: SAS_A0 to MB: SAS_A) SAS cable (BP: SAS_B0 to MB: SAS_B) 3.5 inch x8 SAS/SATA backplane Installing and removing system components...
  • Page 145: Integrated Storage Controller Card

    Figure 95. 3.5 inch x18 internal PERC SAS cable (BP: SAS_A0 to internal PERC card: SAS_A) SAS cable (BP: SAS_B0 to internal PERC card: SAS_B) internal PERC card 3.5 inch x18 SAS/SATA backplane Integrated storage controller card Removing the integrated storage controller card Prerequisites Follow the safety guidelines listed in Safety...
  • Page 146: Installing The Integrated Storage Controller Card

    Figure 96. Removing the integrated storage controller card Next step Install the integrated storage controller card. Installing the integrated storage controller card Prerequisite Follow the safety guidelines listed in Safety instructions. Steps Connect the data cables from the integrated storage controller. Holding the storage controller card firmly, insert the card into the dedicated slot on the system board.
  • Page 147: Replacing The System Battery

    Replacing the system battery Prerequisites WARNING: There is a danger of a new battery exploding if it is incorrectly installed. Replace the battery only with the same or equivalent type recommended by the manufacturer. For more information, see the safety information that shipped with your system.
  • Page 148: Optional Internal Usb Memory Key

    Optional internal USB memory key Replacing the optional internal USB memory key Prerequisites CAUTION: To avoid interference with other components in the server, the maximum permissible dimensions of the USB memory key are 15.9 mm wide x 57.15 mm long x 7.9 mm high. Follow the safety guidelines listed in Safety instructions.
  • Page 149 Figure 100. Removing the control panel assembly To remove the information tag, perform the following steps: Locate and press the tabs on the information tag. b Push the information tag out of the slot to remove it from the control panel. NOTE: Retain the information tag to replace it in the new control panel.
  • Page 150: Installing The Control Panel Assembly

    Installing the control panel assembly Prerequisite Follow the safety guidelines listed in Safety instructions. Steps Replace the blank information tag in the new control panel with the information tag retained from the old control panel. Figure 102. Installing the information tag To install the information tag, push the information tag into the control-panel slot.
  • Page 151: Trusted Platform Module

    Figure 103. Installing the control panel assembly Next steps Install the cooling fan assembly. Follow the procedure listed in After working inside your system. Trusted Platform Module Upgrading the Trusted Platform Module Prerequisites Follow the safety guidelines listed in Safety instructions.
  • Page 152: Initializing Tpm For Bitlocker Users

    Removing the TPM Locate the TPM connector on the system board. Press to hold the module down and remove the screw using the security Torx 8-bit shipped with the TPM module. Slide the TPM module out from its connector. Push the plastic rivet away from the TPM connector and rotate it 90° counterclockwise to release it from the system board. Pull the plastic rivet out of its slot on the system board.
  • Page 153: System Board

    Save the settings. Restart your system. Enter System Setup again. On the System Setup Main Menu screen, click System BIOS > System Security Settings. From the Intel TXT option, select On. System board Removing the system board Prerequisites CAUTION: If you are using the Trusted Platform Module (TPM) with an encryption key, you may be prompted to create a recovery key during program or System Setup.
  • Page 154 Figure 105. Disengaging the system board Figure 106. Removing the system board Installing and removing system components...
  • Page 155: Installing The System Board

    Next step Install the system board. Installing the system board Prerequisite Follow the safety guidelines listed in Safety instructions. Steps Unpack the new system board assembly. CAUTION: Do not lift the system board by holding a memory module, processor, or other components. CAUTION: Take care not to damage the system identification button while placing the system board into the chassis.
  • Page 156 Import your new or existing iDRAC Enterprise license. For more information, see Integrated Dell Remote Access Controller User's Guide , at Dell.com/poweredgemanuals. Restoring the Service Tag using Easy Restore The easy restore feature allows you to restore your service tag, license, UEFI configuration, and the system configuration data after replacing the system board.
  • Page 157: Power Interposer Boards

    Click OK. Power interposer boards Main and GPU power interposer boards connectors Figure 108. Main power interposer board backplane 1 power connector [J_BP1] backplane 0 power connector [J5] P2 power connector [J3] P1 power connector [J_BP0] backplane 2 power connector [J_BP2] PSU 1 connector PSU 2 connector signal cable connector [J4]...
  • Page 158: Removing The Gpu Power Interposer Board

    Figure 109. GPU power interposer board GPU power connector [J_GPU_POWER_225W_J4] GPU power connector [J_GPU_POWER_225W_J5] GPU power connector [J_GPU_POWER_225W_J3] GPU power connector [J_GPU_POWER_225W_J2] main power interposer board link connector Removing the GPU power interposer board Prerequisites Follow the safety guidelines listed in Safety instructions.
  • Page 159: Installing The Gpu Power Interposer Board

    Next step Install the GPU power interposer board. Installing the GPU power interposer board Prerequisite Follow the safety guidelines listed in Safety instructions. Steps Align the guide slots on the GPU power interposer board (PIB) with the guide pins on the chassis. Slide the GPU PIB until the release pin locks into place and secures the PIB.
  • Page 160: Installing The Main Power Interposer Board

    Figure 112. Removing the main PIB Next step Install the main power interposer board. Installing the main power interposer board Prerequisite Follow the safety guidelines listed in Safety instructions. Steps Align the screw holes on the main power interposer board (PIB) with the holes on the system chassis. Using the Phillips #2 screwdriver, secure the main PIB to the system using the screws.
  • Page 161: Converting The System From Tower Mode To Rack Mode

    Converting the system from tower mode to rack mode Your system can be converted from the tower mode to the rack mode. To convert your system from the tower mode to the rack mode, you require the tower to rack conversion kit, which contains the following: •...
  • Page 162 Figure 115. Attaching the mylar cover Install the rack ears by performing the following steps: Align the three screw holes on the rack ears with the screw holes on the top and the bottom of system. b Using a Phillips #2 screwdriver, secure the rack ears to the system. Figure 116.
  • Page 163: Using System Diagnostics

    Using system diagnostics If you experience a problem with your system, run the system diagnostics before contacting Dell for technical assistance. The purpose of running system diagnostics is to test your system hardware without using additional equipment or risking data loss. If you are unable to fix the problem yourself, service and support personnel can use the diagnostics results to help you solve the problem.
  • Page 164: System Diagnostic Controls

    System diagnostic controls Menu Description Configuration Displays the configuration and status information of all detected devices. Results Displays the results of all tests that are run. System health Provides the current overview of the system performance. Event log Displays a time-stamped log of the results of all tests run on the system. This is displayed if at least one event description is recorded.
  • Page 165: Getting Help

    The Contact Technical Support page is displayed with details to call, chat, or e-mail the Dell EMC Global Technical Support team. Documentation feedback You can rate the documentation or write your feedback on any of our Dell EMC documentation pages and click Send Feedback to send your feedback. Getting help...
  • Page 166: Accessing System Information By Using Qrl

    Reference materials, including the Owner’s Manual, and mechanical overview • Your system service tag to quickly access your specific hardware configuration and warranty information • A direct link to Dell to contact technical assistance and sales teams Steps Go to Dell.com/qrl...