Commissioning; First Commissioning - Bosch Rexroth 4WRPEH6 3X Operating Instructions Manual

Directional control and proportional directional valves with io-link interface
Table of Contents

Advertisement

32/44

Commissioning

Bosch Rexroth AG, 4WRPEH6_3X, 4WRPEH10_3X, 4WRPE6_3X, 4WRPE10_3X, 4WRLE_4X; RE 29118-B/09.2021
8 Commissioning
Faulty assembly, leaking hydraulic fluid!
Carelessly or incorrectly mounted valves may become loose during operation,
fall down and cause serious injuries. A powerful hydraulic fluid jet may leak at
incompletely mounted hydraulic connections and connection lines and cause
serious injuries.
Only commission the system after all hydraulic connections and the valve
have been completely and properly mounted according to the specifications.
Look out for defective sealing points and exchange defective seal rings
immediately.
Wear personal protective equipment during the initial commissioning.
Inadmissibly high operating pressure!
In hydraulic applications with different area ratios, the hydraulic pressure is
fortified and may - in case of incorrect design - lead to exceedance of the maximum
admissible operating pressure. Valves may burst, or the cap elements may fly
around and cause serious injuries.
Ensure before the commissioning of the hydraulic system that the maximum
admissible pressure of the valve in the system is not exceeded by any means.
Ensure that in your system, the maximum admissible operating pressure is
secured by means of a pressure relief valve.
Commissioning by persons without the required knowledge!
Danger of damage to property and personal injuries. Commissioning of the valve
requires basic hydraulic and electrical/electronical knowledge.
The valve may only be commissioned by qualified staff.

8.1 First commissioning

Prior to commissioning, make sure that all electrical and hydraulic connections
are either used or covered. Commission the product only if it is installed
completely.
Make sure that only hydraulic fluid specified in the valve data sheet is used.
Allow the valve to acclimatize for some time prior to commissioning as the
electronics might be damaged by the generation of condensed water.
Immediately depressurize the system if hydraulic fluid still leaks despite proper
assembly and continue with chapter 14 "Troubleshooting".
WARNING

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents