Channel Types - GE Bently Nevada 3300/25 Operation Manual

Dual accelerometer input monitor
Table of Contents

Advertisement

18.5 Channel Types

TRANSDUCER INPUT,
CHANNEL UNITS
Dual Accelerometer,
Channel A Acceleration
Channel B Acceleration
** Dual Accelerometer,
Channel A Acceleration
Channel B Velocity
** Dual Accelerometer,
Channel A Velocity
Channel B Velocity
* Single Accelerometer,
Channel A Acceleration
Channel B Acceleration
* ** Single Accelerometer,
Channel A Acceleration
Channel B Velocity
* ** Single Accelerometer,
Channel A Velocity
Channel B Velocity
NOTE: * Single accelerometer transducer must be connected to channel A. No
connection is made to channel B. For Trip Multiply Monitors (option GG -01, -02),
ensure that W21 is removed when a single transducer input is used.
** When integrated, low frequency signals can cause the monitor to saturate.
Section 18 - Appendix A–Main Board Options
JUMPERS
INSTALL
W3B,E
W6B,E
W22B
W3B,F
W6B,E
W22B
W3B,F
W6A,E
W22B
W1
W3B,E
W6B,E
W22A
W1
W3B,F
W6B,E
W22A
W1
W3B,F
W6A,E
W22A
REMOVE
W1
W3F
W6A
W22A
W1
W3E
W6A
W22A
W1
W3E
W6B
W22A
W3F
W6A
W22B
W3E
W6A
W22B
W3E
W6B
W22B
51