• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 80 °FDB/67 °FWB (26.7 °CDB/19.4 °CWB), and outdoor temperature of 95 °FDB/75 °FWB (35 °CDB/23.9 °CWB).
– Heating: Indoor temperature of 70 °FDB/60 °FWB (21.1 °CDB/15.6 °CWB), and outdoor temperature of 47 °FDB/43 °FWB (8.3 °CDB/6.1 °CWB).
– Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *1: This value is "Cooling operation/Heating operation".
• *2: Sound pressure level:
–
Measured values in manufacturer's anechoic chamber.
–
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
2-8. Compact floor type
Cooling
Heating
HIGH
MED—HIGH
MED
CFM (m
MED—LOW
LOW
QUIET
HIGH
MED—HIGH
MED
MED—LOW
LOW
QUIET
Length
Fin pitch
Rows × Stages
Face area
Pipe type (Material)
Type (Material)
Fin
Surface treatment
Type
Net material
Material
Color
Net
Gross
Net
Gross
Liquid (Flare)
Gas (Flare)
Drain hose
AGUA4TLAV1
Btu/h
4,000
kW
1.2
Btu/h
4,400
kW
1.3
W
1
12/14*
1
1
224/253*
(380/430*
)
206 (350)
188 (320)
3
/h)
182 (310)
165 (280)
124 (210)
W
1
35/36*
33
31
dB (A)
30
28
22
in (mm)
FPI
2
2
ft
(m
)
Approximate color of Munsell 5Y 9/0.5NN
23-5/8 × 29-1/8 × 7-7/8 (600 × 740 × 200)
in (mm)
27-9/16 × 32-5/16 × 12-3/16 (700 × 820 × 310)
lb (kg)
41 (18.5)
in (mm)