AVIOTEC IP starlight 8000
Auxilliary 12 V DC power supply
Caution!
Use only a +12 VDC power supply as an auxiliary power source.
!
The auxiliary power supply unit must be isolated from earth.
Caution!
The Low Voltage power supply unit must comply with EN/UL 60950. The power supply must
!
be a SELV-LPS unit or a SELV - Class 2 unit (Safety Extra Low Voltage - Limited Power
Source).
The camera can be supplied with a power supply in case of missing PoE feature of the
network or for redundancy reasons.
Connect an approved power supply unit with a rated supply voltage of 12 VDC as follows:
1.
2.
3.
4.8

Alarm output

The alarm contact assignment is shown in the figure below:
Bosch Sicherheitssysteme GmbH
Strip back 7 mm (0.28 in) of insulation on the power supply cable (must be 16-28 AWG,
UL 14-30 AWG).
Loosen the screws of the supplied 2-pole connector and insert the stripped wires, then
tighten the screws again.
Insert the 2-pole connector into the camera power socket.
4
5
6
|
4
5
6
D
A
A
L
T
A
A
R
M
1
2
3
|
1
2
3
- +
CVBS
Alarm
|
4 5 6
|
1 2 3
Operation and Commissioning Manual
E
T
H
-
P
o
E
MENU
(0.08 in)
Installation | en
7 mm
(0.28 in)
≤2 mm
2020.08 | 01 | F.01U.391.015