Parameter Lists
Par. No. # Parameter description
H-21
Motor Feedback Speed Error
H-22
Motor Feedback Loss Timeout
H-23
Motor Check At Start
H-24
Tracking Error Function
H-25
Tracking Error
4
4
H-26
Tracking Error Timeout
H-27
Tracking Error Ramping
H-28
Tracking Error Ramping Timeout
H-29
Tracking Error After Ramping Timeout
H-3#
H-30
Motor Speed Monitor Function
H-31
Motor Speed Monitor Max
H-32
Motor Speed Monitor Timeout
H-4#
H-40
Configuration Mode
H-41
Motor Control Principle
H-42
Flux Motor Feedback Source
H-43
Torque Characteristics
H-44
Constant or Variable Torque OL
H-45
Local Mode Configuration
H-46
Back EMF at 1000 RPM
H-47
Motor Angle Offset
H-48
Clockwise Direction
H-49
Motor Angle Offset Adjust
H-5#
H-50
Motor Magnetisation at Zero Speed
H-51
Min Speed Normal Magnetising [RPM]
H-52
Min Speed Normal Magnetising [Hz]
H-53
Model Shift Frequency
H-54
Voltage reduction in fieldweakening
H-55
U/f Characteristic - U
H-56
U/f Characteristic - F
H-58
Flying Start Test Pulses Current
H-59
Flying Start Test Pulses Frequency
H-6#
H-61
High Speed Load Compensation
H-62
Brake Check Limit Factor Source
H-63
Brake Check Limit Factor
H-64
Resonance Dampening
H-65
Resonance Dampening Time Constant
H-66
Min. Current at Low Speed
H-67
Torque Limit Factor Source
H-68
Speed Limit Factor Source
H-7#
H-70
Warning Current Low
H-71
Warning Current High
H-72
Warning Speed Low
H-73
Warning Speed High
H-74
Warning Reference Low
H-75
Warning Reference High
H-76
Warning Feedback Low
170
Default value
4-set-up
300 RPM
All set-ups
ExpressionLimit
All set-ups
[0] Off
All set-ups
ExpressionLimit
All set-ups
10 RPM
All set-ups
1 s
All set-ups
100 RPM
All set-ups
1 s
All set-ups
5 s
All set-ups
[0] Disabled
All set-ups
100 RPM
All set-ups
0.1 s
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[1] 24V encoder
All set-ups
[0] Constant torque
All set-ups
[0] High torque
All set-ups
[2] As mode par H-40
All set-ups
ExpressionLimit
All set-ups
0 N/A
All set-ups
[0] Normal
All set-ups
[0] Manual
All set-ups
100 %
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0 V
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
100 %
All set-ups
[0] DC-link voltage
All set-ups
98 %
All set-ups
100 %
All set-ups
5 ms
All set-ups
ExpressionLimit
All set-ups
[0] No function
All set-ups
[0] No function
All set-ups
0 A
All set-ups
Imax (DR-37)
All set-ups
0 RPM
All set-ups
ExpressionLimit
All set-ups
-999999.999 N/A
All set-ups
999999.999 N/A
All set-ups
ExpressionLimit
All set-ups
02/2016 All rights reserved.
Change
Conver-
Type
during
sion index
operation
TRUE
67
Uint16
TRUE
-2
Uint16
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
67
Uint16
TRUE
-2
Uint16
TRUE
67
Uint16
TRUE
-2
Uint16
TRUE
-2
Uint16
TRUE
-
Uint8
TRUE
67
Uint16
TRUE
-2
Uint16
TRUE
-
Uint8
FALSE
-
Uint8
FALSE
-
Uint8
TRUE
-
Uint8
FALSE
-
Uint8
TRUE
-
Uint8
FALSE
0
Uint16
FALSE
0
Int16
FALSE
-
Uint8
FALSE
-
Uint8
TRUE
0
Uint16
TRUE
67
Uint16
TRUE
-1
Uint16
FALSE
-1
Uint16
FALSE
0
Uint8
TRUE
-1
Uint16
TRUE
-1
Uint16
FALSE
0
Uint16
FALSE
0
Uint16
TRUE
0
Int16
TRUE
-
Uint8
TRUE
0
Uint8
TRUE
0
Uint16
TRUE
-3
Uint8
TRUE
0
Uint32
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-2
Uint32
TRUE
-2
Uint32
TRUE
67
Uint16
TRUE
67
Uint16
TRUE
-3
Int32
TRUE
-3
Int32
TRUE
-3
Int32
DET-618D