Installation
4–2
4.1

Installed positions and clearances

Housing:
Front panel:
aluminum housing:
Weight:
approx. 8 kg
Installed
vertical, 0_ up to max. "45_ inclined position
position:
Installation
for gallows mounting, sealed as per IP54
type:
.
Remember that the front of the control panel may become dirty more
quickly if installed at an angle, instead of being installed vertically.
CAUTION
Excessive operating temperature!
Do not expose the housing of the CPS21T to direct sunlight or other
sources of heat radiation!
CPS21T
100
Installation
position max. "45_
D Install the control panel, ensuring that it can be operated ergonomically.
In addition, the operator must be provided with a permanent and unob-
structed line of sight on moving machine components!
Protection category IP 65
Protection category IP 54
Stud
connection
top
100
Minimum 100 mm all–round
clearance for cooling 100mm
required
100
1070 073 826-101 (01.10) GB