80
en | Programming sheets
Zone Status Reporting Options
5
6
7
NOTICE!
The system sends no report when programmed to report to the receiver as Option 0.
10.2.2

Test Report Time Interval Setting

Location 145-150
145-146=timer test report(1-99 hours)0=don't send timer
test report
147-148=Report time: Hours=0-23(else=don't send real time
test report)
149-150=Report time: minutes=0~59(else=don't send real
time test report)
10.3

System Functions Programming

10.3.1

Ring Count

Location 152
0=Panel does not answer
1–15= Number of rings until panel answers
10.3.2

Remote Programming/Control

Location 153
0=Disable 1=Enable
10.3.3

Call back Telephone Number

Location 154-169
15 = telephone termination
10.3.4

Exit Time

Location 170-172
000-255 seconds
10.3.5

Entry Time

Location 173-175
000-255 seconds
F.01U.241.127 | V4 | 2011.12
Report to Receiver 1,2,3,4
Report to destination 1 (2,3,4 backup)
Report to destination 1 (2 backup) and destination 3 (4 backup)
Installation Manual
AMAX panel 2000 / AMAX panel 2000 EN
Default
EN=1-24
24
99
99
Location Default
152
0
Location Default
153
1
Location Default
154-169
15
Location Default
170-172
045
Location Default
173-175
045
EN=45