Keypad 2 Fail; Dx3010 Fail; B420/Dx4020/Its-Dx4020G Fail - Bosch AMAX panel 2000 Installation Manual

Hide thumbs Also See for AMAX panel 2000:
Table of Contents

Advertisement

AMAX panel 2000 / AMAX panel 2000 EN
1.
2.
3.
4.
5.1.2

Keypad 2 fail

Condition:
1.
NOTICE!
Keypad 2 fail is only reported when Keypad 2 was connected during powering up the system!
Restore:
Communication between panel and keypads comes back to normal and fault is reset.
Supervise:
1.
2.
3.
4.
5.1.3

DX3010 Fail

Condition:
No communication with DX3010 if DX3010 is programmed.
Restore:
Communicaiton with DX3010 is normal and fault is reset.
Supervise:
1.
2.
3.
5.1.4

B420/DX4020/ITS-DX4020G Fail

Condition:
No communication with the DX4020/ITS-DX4020G if DX4020/ITS-DX4020G is programmed.
Restore:
Bosch Sicherheitssysteme GmbH
Report the keypad fault to the configured destination programmed on location 140.
Flash FAULT indicator on the other keypad in normal operation (refer to the detailed
description in chapter keypad indicators).
Keypad missing communication with the panel performance as below:
Stop detection on the keypad button
Flash FAULT indicator
The disconnected keypad do not sound FAULT beeping per minute
When the keypad fault is reset, send the restore report to the configured destinations.
The FAULT indicator is turned off when there is no other system fault.
Keypad fail is reported at any time when communication fails between the panel and
address 2 keypad.
Report the keypad fault to the configured destination programmed on location 140.
Flash FAULT indicator on the other keypad in normal operation (refer to the detailed
description in chapter keypad indicators).
Keypad missing communication with the panel performance as below:
-Stop detection on the keypad button
-Flash FAULT indicator
-The disconnected keypad does not sound FAULT beeping per min
When the fault is reset, send the restore report to the configured destinations of the
control panel system. The FAULT indicator is turned off when there is no other system
fault.
Report the DX3010 fault to configured destination on location 140 when the fault is
detected.
Slow flash FAULT indicator (refer to the detailed description in chapter keypad
indicators)
When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
Installation Manual
Fault and Tamper Description | en
F.01U.241.127 | V4 | 2011.12