Bosch REXROTH IndraControl VEH 30.2 Project Planning Manual page 44

Hand-held terminal
Table of Contents

Advertisement

42/109
Bosch Rexroth AG
Technical Data
Technical systems as interference
sources
Technical systems as interference
Technical systems can act as interference sources. In doing so, the interfer‐
ence may be intentional or unintentional. Electromechanical energy is often
also used for material processing.
Periodically occurring interference:
Ignition impulses of combustion engines
Sparking of commutator motors
Electromagnetic fields of induction furnaces, arc welding devices, micro‐
wave ovens etc.
Pulse currents from frequency converters and switching power supplies
Electromagnetic fields of radio and telecommunications devices
Randomly occurring interferences are:
Ignition impulses of fluorescent lamps
Switching procedures on inductive electrical circuits
Contact bounces when closing or opening switching contacts
Voltage fluctuations on heavy load switching procedures
There is a series of test standards for the above listed interference sources,
intentionally or unintentionally caused by technical systems, which simulate
these interferences:
IEC 61000-4-3 High Frequency Electromagnetic Field Immunity Test
IEC 61000-4-4 Electrical Fast Transient / Burst Immunity Test
IEC 61000-4-6 Test of Immunity to Conducted Disturbances, Induced by
High Frequency Fields
IEC 61000-4-8 Power Frequency Magnetic Field Immunity Test
IEC 61000-4-11 Voltage Dips, Short Interruptions and Voltage Varia‐
tions Immunity Test
All international standards listed here are also available as European stand‐
ards. The Product Standard IEC 61131-2 demands testing to these Stand‐
ards and also defines the severity level.
In the case of functional interference, EMC problems first arise at interference
sinks
sinks. The following interference sinks can be identified dependent on the de‐
gree of immunity to electromagnetic influences:
Fig.4-5:
Examples for technical systems as interference sinks
Control systems without integrated switching circuits are unthinkable and
would therefore not be sufficiently immune without suitable EMC measures.
DOK-SUPPL*-VEH*30.2***-PR03-EN-P
Rexroth IndraControl VEH 30.2 Hand-Held Terminal

Advertisement

Table of Contents
loading

Table of Contents