Computed Sources - Bosch C60 Manual

Hide thumbs Also See for C60:
Table of Contents

Advertisement

10 | Analog and Frequency Inputs

10.9 Computed sources

10.9.1 Configuring computed sources
64 / 108
5.
Click 'Finish' when done.
6.
Enter channel name and description.
7.
Click 'OK' when done.
The channel is inserted into the C 60 Project Tree.
Available measurements for channel:
Measurement label
raw_name
raw_name_fi
name
name_fi
NOTICE
Measurement of 'Revolution' is similar.
Computed sources receive data from a measurement channel rather than an input pin.
– Sensitivity/Offset calculation on input channel
– Characteristic curve calculation on input channel
– Computed vehicle speed
– PWM output control (covered in a special section)
– Lap trigger (covered in a special section)
Example: Sensitivity/offset calculation on input channel
1.
Click 'Measurement Sources' in the Toolbox.
2.
Drag the 'Sensitivity/Offset' computed source from the Toolbox and drop it on 'Com-
puted Channels' in the C 60 Project Tree.
Data Logger C 60
Special functionality for sensors
with frequency offset (e.g.
Correvit) Set to '0' for wheelspeed
measurement
Number of teeth on the pulse
wheel
Circumference of wheel for
speed calculation
Choose data type of the
measurement variable
Enter name to automatically
create a new measurement
sheet
Function
mV value of sensor
filtered mV value of sensor
physical value of sensor
filtered physical value
Bosch Motorsport

Advertisement

Table of Contents
loading

Table of Contents