10 Analog and Frequency Inputs
24 analog inputs with Software Upgrade 2; 4 analog inputs without upgrade
– 0 ... 5 V
– 12 bit A/D converter
– Switchable 3.01 kOhm pull-up resistor
– 8 kHz acquisition rate, up to 1 kHz recording rate
– Linear phase digital filter
4 frequency inputs with Software Upgrade 2; no frequency inputs without upgrade
– 5 V Hall-effect type, 2.5 V trigger level
– 20 kHz max. frequency
– 10 ms measurement window
4 PWM outputs
– Low-side switch
– Up to 2 A each
– Output frequency selectable
Measurement channels
For each analog channel, several 'subchannels' are available.
Measurement labels with the characters 'raw' show the exact values in mV.
Measurement labels with the characters '_fi' show filtered values.
The word 'name' in the table is a placeholder for the channel's name.