Figure 13: D6680 Encryption - Bosch Conettix D6680 Installation Instructions Manual

Ethernet network adapter
Table of Contents

Advertisement

If you use a password, store it in a secure
place. If the password is lost or forgotten
you can not connect to the telnet program
on this unit again. The unit must be sent
back to the factory and reconditioned
before it can receive another telnet session.
15. Press [1] [ENTER] to set up the configuration for
Channel 1. Baudrate 9600 appears.
The baud rate of the D6680 must be
38400.
16. Type 38400 and press [ENTER] to change the
baudrate.
I/F Mode (4C) ? should appear.
17. Press [ENTER] to accept the default of (4C), or
type 4C and press [ENTER] to change the value.
Flow (00) ? should appear.
18. Press [ENTER] to accept the default of (00), or
type 00 and press [ENTER] to change the value.
Port No (13257) ? should appear.
19. For the Port number, type a number between
2000 and 10000 and press [ENTER].
If using two channels, set different port
numbers for Channel 1 and Channel 2
(shown in the Telnet configuration screen).
ConnectMode (CC) ? should appear.
20. Press [ENTER] to accept the default of (CC), or
type CC and press [ENTER] to change the value.
Datagram Type (00) ? should appear.
21. Type 00 and press [ENTER] if all field devices
(C900TTL-E, D9133TTL-E, and DX4020) are
using the same port number entered in Step 18.
To use Datagram Type 02, firmware version
5.5c or later is required for Hardware
Revision 2. Refer to the Device Installer
Operation and Installation Guide
(P/N: 4998138688) for more information.
22. Type 02 and press [ENTER] if all field devices
(C900TTL-E, D9133TTL-E, and DX4020) are
using unique port numbers.
If Datagram Type 02 is used, enable it in
the D6600 Receiver refer to the D6600
Program Entry Guide (P/N: 4998122702).
Bosch Security Systems, Inc. | 5/07 | 4998138732-01
Conettix D6680 | Installation Instructions | 3.0 Configuration and Programming
Available from A1 Security Cameras
www.a1securitycameras.com email: sales@a1securitycameras.com
For more information on Datagram Types,
refer to the Conettix D6600 System Guide
(P/N: 4998122712).
23. If you want to enable encryption, select 6 Security
from the main menu and continue with Step 24.
If encryption is enabled on the D6680
(refer to Figure 13), you must enable it on
all field devices (C900TTL-E, D9133TTL-E,
DX4020) with the same key. Encryption
must also be enabled in the D6600
Receiver. Refer to the D6600 Program
Entry Guide (P/N: 4998122702).
The network interface module (D6680,
C900TTL-E, D9133TTL-E, or DX4020)
must have the proper software version to
support encryption. For more details, refer
to the Device Installer Operation and
Installation Guide (P/N: 4998138688).

Figure 13: D6680 Encryption

24. At Disable SNMP (N) N, press [ENTER].
25. At SNMP Community Name ( ): press [ENTER].
26. At Disable Telnet Setup (N) N, press [ENTER].
27. At Disable Port 77Feh (N) N, press [ENTER].
28. At Disable Web Server (N) N, press [ENTER].
29. At Disable ECHO ports (Y) Y, press [ENTER].
30. At Enable Encryption (N), press [ENTER].
31. At Change keys (N), press 'Y'. Enter keys as
follows:
These 16 bytes (32 characters) should match
the bytes programmed in the D6680.
Default value is 01-02-03-04-05-06-07-08-09-10­
11-12-13-14-15-16.
11