RAID Subsystem DVA-08K | Installation Manual
NOTICE!
i
The subsystem has been designed to run continuously. If a hot-replaceable component fails,
the fault can be corrected online.
5.4.5

LCD Screen

When powering on the subsystem, the following messages should appear on the front panel
LCD screen. Wait for the front panel LCD to show "READY" or "No Host LUN" before turning
on the host computer. Refer to Figure 5.3 on how to read the screens.
Fig. 5.3 The LCD Initial Screen
The LCD screen startup sequence is shown and described in the sequence below:
Bosch Security Systems
Subsystem Connection and Operation | en
This screen appears when the PSUs are turned
on.
Proceeding with controller self-test.
Self-test completed.