Installer Setup (Isu) Table - Honeywell VisionPRO 8000 Product Data

With wi-fi
Hide thumbs Also See for VisionPRO 8000:
Table of Contents

Advertisement

ISU
Installer Setup
Number
Name
101
Application
Residential
Commercial
103
Thermostat Name
[Select Thermostat Name]
104
Thermostat Type
Non-Programmable
Programmable
105
Temperature Scale
Fahrenheit
Celsius
106
Outdoor Temp
Wired/Internet
No
200
Heating System
Conv. Forced Air
Heat Pump
Radiant Heat
Other
None (Cool Only)
201
Heating
Heat Pump:
Equipment
Air to Air Heat Pump
Geothermal
Geothermal Radiant
202
Radiant Heat
0
1
Stages
2
203
Radiant Stage 1
None
U1
205
Geo Forced Air
None
Cooling Only
Heating and Cooling
206
Reversing Valve
O (O/B on Cool)
B (O/B on Heat)
Table 2. Installer Setup (ISU) Table.
Settings
Default
Residential
Thermostat
Programmable
Fahrenheit
No
Conv. Forced Air
Air to Air Heat Pump Both
Default varies based
on previous
selections
Heating and Cooling Both
O/B on Cool
Residential,
Commercial
or Both
Both
Both
The Web Interface displays the name of the
thermostat that you enter on this screen.
Both
Both
Both
Select Wired/Internet to indicate that you are
going to connect a wired outdoor sensor or
connect to the internet. This will allow you to
configure settings prior to the Internet being
connected.
Select No if you are not going to connect to an
outdoor sensor or the Internet.
Both
For Dual Fuel, choose Heat Pump.
This ISU is not displayed when ISU 200 Heating
System is set to Conv. Forced Air, Radiant
Heat, Other or None (Cool Only).
See "Geothermal Radiant Heat" beginning on
page 56.
Both
Select the number of radiant heat stages.
Both
This ISU is only displayed when ISU 201
Heating Equipment is Geothermal Radiant.
Geothermal Radiant Heat must be wired to
universal terminal U1.
U1 is a normally open set of dry contacts. U1
requires power from the system transformer or
a separate transformer.
This thermostat has the capability of controlling
Geothermal Radiant Heat, Geothermal Forced
Air and Backup Heat.
If this thermostat is not controlling the
Geothermal Forced Air System, select None.
This setting is typically used if the thermostat is
only controlling Geothermal Radiant Heat.
If this thermostat is using the Geothermal
Forced Air System for cooling and not for
heating, select Cooling Only.
If this thermostat is using the Geothermal
Forced Air System for both heating and cooling,
select Heating and Cooling.
Both
Only displayed if the equipment type is Air to Air
Heat Pump, Geothermal or Geothermal Radiant.
11
®
VISIONPRO
8000 WITH WI-FI
Notes
33-00096—01
®