22
en | Operation with ICON LCD Codepad
How to Program the Telco Disarm Sequence
1.
2.
3.
4.
Notice!
To disable the Telco Disarm Sequence, enter the Call Forward Sequence as [*5] (terminator)
for Step 3.
Digit Required
0
1
2
3
4
5
6
7
Tab. 5.8: Dialing Digits
5.12

Testing

The following functions let you confirm that your system is operating correctly:
5.12.1
Horn Speaker Test
Hold the [1] key until two beeps sound.
The horn speaker sounds for 2 sec.
5.12.2
Bell Test
Hold the [2] key until two beeps sound.
The bell output operates for 2 sec.
5.12.3
Strobe Test
1.
2.
5.12.4
Walk Test Mode
Use Walk Test Mode to test detection devices to ensure that they are operating correctly.
Every time you test a zone, the codepad sounds one long beep, and the horn speaker sounds
one short beep to indicate that the zone is activated when testing.
2017.09 | 04 | F.01U.298.028
Enter your Master Code, followed by the [3] and [#] keys (for example, [25803#]). Three
beeps sound, and the STAY and AWAY indicators flash.
Press the [2] key followed by the [#] key to select the Telco Disarm Sequence. Three
beeps sound.
Enter the Call Forward Disable Sequence (for example, [#61#] to disable the No Answer
Call Forward sequence, or [#21#] to disable the Call Forward Immediate Sequence).
Press the [#] key when finished. Two beeps sound, and the STAY and AWAY indicators
turn off.
Number to Program
0
1
2
3
4
5
6
7
Hold the [3] key until three beeps sound. The strobe flashes.
Hold the [3] key until two beeps sound. The strobe stops flashing.
Digit Required
8
9
*
#
4-sec Pause
Terminator
User's Guide
Control Panel
Number to Program
8
9
* 1
* 2
* 3
* 5
Bosch Security Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solution 3000

Table of Contents