Table 3-21     Problems resolved in versions prior to XCP 2050 (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
130507-001
RTIF2-
x
x
x
130515-001
RTIF2-
x
x
x
130516-005
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
158
Description
There is a case where a RAID volume
cannot be recognized after a power
failure occurred while using the
hardware RAID function.
While the system is operating, the
following events may occur:
1. The prtpicl command no longer
responds.
2. Display data (such as the XCP version)
of prtpicl -v and prtdiag -v is not
output as expected.
3. For /var/adm/messages, the warning
message, "PICL snmpplugin: cannot
fetch object value", is output.
4. XSCF CMDD process shutdown
occurs and an XSCF is reset
repeatedly, such that it becomes
unusable. At this time, system
operation can be continued.
If the showcodactivation(8) command is
executed while data is being restored
with the restoreconfig(8) or
restorecodactivation(8) command, it may
be impossible to display the execution
results. If this occurs, the
showcodactivation(8) command ends
with a "codd internal error".
Workaround
Please run the activate-volume command
at ok prompt to activate a hardware
RAID volume.
For the detailed procedure, see "12.2.8
Re-enabling hardware RAID volume" in
the Fujitsu M10/SPARC M10 Systems
System Operation and Administration Guide.
There is no effective workaround.
[How to restore]
- If event 1 occurs:
Recover with the following procedure.
1. End the prtdiag(1M) command with
[Ctrl] + [C].
2. Wait for about 30 minutes, and allow
an SNMP timeout to occur in the
XSCF.
3. In the control domain, execute the
svcadm(1M)command to restart the
picl service.
- If event 2 occurs:
Execute the command again. If results
are displayed, the system can be
operated continuously. If the state
where results are not displayed as
expected continues, check whether the
XSCF is operating.
- If the XSCF is operating, use the
rebootxscf(8) command to reset the
XSCF.
- If the XSCF is not operating, turn the
input power supply of the system off
and then back on (AC OFF/ON) to
recover.
- If event 3 occurs:
The system can be operated
continuously because this is a
temporary warning message.
- If event 4. occurs:
Turn off the input power supply of the
system, and then back on (AC
OFF/ON) to recover.
The execution results can be displayed if
the showcodactivation(8) command is
executed after the execution of the
restoreconfig(8) or restorecodactivation
(8) command is completed.