Table 3-11 Problems resolved in XCP 2220 (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
140507-015
RTIF2-
x
x
x
140507-017
RTIF2-
x
x
x
140507-018
Description
If the showhardconf(8) command is
executed on a system configuration with
3 or more BBs or crossbar boxes, wrong
information may be output at the
FRU-Part-Number of the crossbar cable.
[Example]
In case of crossbar cable no. R0:
Error:
CBL#R0 Status:Normal;
+ FRU-Part-Number:@@@D00Q@;
Ver:0020h;
+ Type:Optic; Length: 2;
Correct:
CBL#R0 Status:Normal;
+ FRU-Part-Number: ALLT03FQPE;
Ver:0020h;
+ Type:Optic; Length: 2;
If XSCF is reset using the rebootxscf(8)
command, the XSCF may stop due to
XSCF failure.
When the system is in the initialized
state, XSCF may not start even after
turning on the input power.
Workaround
There is no effective workaround.
There is no effect of this wrong display
on the system.
There is no effective workaround.
[How to Restore]
Turn off/on the input power (AC
OFF/ON) of the system.
There is no effective workaround.
[How to Restore]
Replace the CPU memory unit lower
(CMUL), the XSCF unit (XSCFU), or the
motherboard unit (MBU).
Chapter 3 Information on Software