8.3.2 Connecting base station-extension card

The connection of the base stations to the BS 8-15 connector of the extension card
(see figure 8.3) can be done in two different ways. One way is to solder the 25 pole male
sub D connector to the base station cables (see 1.), the other way is buying a BS-DCU
connection cable LBB 6721/02 (see 2.).
1. Soldering the wires to a 25-pole male sub D connector according the pin
configuration in Table 8.1 and plug the connector on the BS 8-15 connector of the
extension card (see figure 8.3).
Table 8.1 Base station to DCU connector
2. Connect the optional BS-DCU connection cable to the BS 8-15 connector of the
extension card (see figure 8.3) and the wires via a terminal strip, located near by a
PABX, to the base stations (see figure 8.5). For wiring of the BS-DCU connection
cable LBB 6721/02 see Table 8.2.
Pin
Signal
1
a
14
b
2
a
15
b
3
a
16
b
4
a
17
b
Table 8.2 Connections of the BS-DCU connection cable LBB 6721/02
Pin
Signal
1
a
14
b
2
a
15
b
3
a
16
b
4
a
17
b
Wire colour
Line
white/blue
8
blue/white
white/orange
9
orange/white
white/green
10
green/white
white/brown
11
brown/white
DECT6000
Line
Pin
Signal
5
a
8
18
b
6
a
9
19
b
7
a
10
20
b
8
a
11
21
b
9...13
Not connected
22...25
Not connected
Pin
Signal
Wire colour
5
a
white/grey
18
b
grey/white
6
a
red/blue
19
b
blue/red
7
a
red/orange
20
b
orange/red
8
a
red/green
21
b
green/red
9...13
Not connected
22...25
Not connected