Bosch DCN Installation And User Instructions Manual page 38

Wireless discussion system
Table of Contents

Advertisement

DCN Wireless | Installation and User Instructions | Central Devices
4 Connect the power cable to a power supply.
Warning
Make sure that the mains power supply is
grounded. Electrical discharges from the mains
power supply can kill you.
10.5.2 DCN
Connect the trunk of the DCN to the DCN sockets of
the central control unit (refer to figure 10.5).
LED
figure 10.5: DCN
Each DCN socket has a red LED that comes on if there
is an overload (refer to figure 10.5 and 3.5.4).
table 10. 1 0: DCN connection
Number of connections:
2x DCN socket
Location:
Rear side
Power supply:
max. 65 W
Bosch Security Systems | 2007-11 | 9922 141 70691 en
10.5.3 Optical network
Connect the trunk of the optical network to the optical
network sockets of the central control unit with optical
network cables (refer to figure 10.6).
LED
figure 10.6: Optical network
Each optical network socket has a red LED that comes
on if there is an overload (refer to figure 10.6 and 3.5.4).
table 10. 1 1: Optical network connections
Number of connections:
2x proprietary sockets
Location:
Rear side
Nodes:
2
Power supply:
max. 65 W (refer to figure 3. 1 )
en | 38