Bosch AHP 641-242 Manuals

Manuals and User Guides for Bosch AHP 641-242. We have 1 Bosch AHP 641-242 manual available for free PDF download: User Manual

Bosch AHP 641-242 User Manual

Bosch AHP 641-242 User Manual (42 pages)

I/O ZONE 560/583, zone controller  
Brand: Bosch | Category: Control Units | Size: 7.43 MB
Table of contents
Table Of Contents2................................................................................................................................................................
The Zone Controller4................................................................................................................................................................
Specifications5................................................................................................................................................................
Controller Components6................................................................................................................................................................
Led Indicators6................................................................................................................................................................
Dip And Rotary Switches7................................................................................................................................................................
Jumpers And Settings8................................................................................................................................................................
Lonworks® Card Option9................................................................................................................................................................
Water To Air Operation10................................................................................................................................................................
General Description10................................................................................................................................................................
Key Features And Benefits10................................................................................................................................................................
Inputs11................................................................................................................................................................
Outputs11................................................................................................................................................................
Control & Status Parameters And Alarms11................................................................................................................................................................
Control11................................................................................................................................................................
Status12................................................................................................................................................................
Alarms12................................................................................................................................................................
Sequence Of Operation13................................................................................................................................................................
Run Conditions13................................................................................................................................................................
Occupied Mode13................................................................................................................................................................
Unoccupied Mode (night Setback)13................................................................................................................................................................
Zone Temperature14................................................................................................................................................................
High Zone Temp14................................................................................................................................................................
Low Zone Temp14................................................................................................................................................................
Zone Sensor Failure14................................................................................................................................................................
Zone Setpoint Adjust14................................................................................................................................................................
Zone Unoccupied Override14................................................................................................................................................................
Freeze Protection15................................................................................................................................................................
Fan15................................................................................................................................................................
Constant Volume15................................................................................................................................................................
Vav15................................................................................................................................................................
Zone Humidity15................................................................................................................................................................
Hot Gas Re-heat Valve On/off15................................................................................................................................................................
Modulating Re-heat Valve16................................................................................................................................................................
Filter16................................................................................................................................................................
Heating And Cooling - (1 And 2 Compressor Stages)16................................................................................................................................................................
The Heating Will Be Enabled Whenever17................................................................................................................................................................
The Cooling Will Be Enabled Whenever17................................................................................................................................................................
Reversing Valve17................................................................................................................................................................
Supplemental Electric Heating Stage17................................................................................................................................................................
Discharge Air Temperature18................................................................................................................................................................
High Discharge Air Temp18................................................................................................................................................................
Low Discharge Air Temp18................................................................................................................................................................
Discharge Air Sensor Failure18................................................................................................................................................................
Discharge Air Control18................................................................................................................................................................
Single Outside Air Temperature (oat) Reset19................................................................................................................................................................
Multiple Outside Air Temperature (oat) Reset19................................................................................................................................................................
Leaving Water Temperature20................................................................................................................................................................
High Leaving Water Temp20................................................................................................................................................................
Low Leaving Water Temp20................................................................................................................................................................
Leaving Water Sensor Failure20................................................................................................................................................................
Water To Water Operation27................................................................................................................................................................
Status And Control28................................................................................................................................................................
Auto Changeover Mode29................................................................................................................................................................
Digital Input Mode30................................................................................................................................................................
Bas Mode30................................................................................................................................................................
Lead - Lag Compressor Operation31................................................................................................................................................................
Compressor 1 Runtime31................................................................................................................................................................
Compressor 2 Runtime31................................................................................................................................................................
Pump Control (optional)31................................................................................................................................................................
Pump Runtime Alarm31................................................................................................................................................................
Load Water (entering) Temperature32................................................................................................................................................................
Load High Temp32................................................................................................................................................................
Load Low Temp32................................................................................................................................................................
Load Sensor Failure32................................................................................................................................................................
Source Water (leaving) Temperature32................................................................................................................................................................
Leaving High Temp32................................................................................................................................................................
Leaving Low Temp32................................................................................................................................................................
Leaving Sensor Failure32................................................................................................................................................................
Bacview Termination Detail36................................................................................................................................................................
Rs-sensor Termination Detail37................................................................................................................................................................

Advertisement

Share and save

Advertisement