Download Print this page

IEI Technology TRI-GARD 555LS Signature Series Quick Manual

Audio glassbreak detectors

Advertisement

Quick Links

555LS/557LS Signature Series
TRI-GARD
A u d i o G l a s s b r e a k D e t e c t o r s
555LS
TRI-GARD 555LS/557LS SIGNATURE SERIES™
audio glassbreak detectors employ state-of-the-art Advanced
Signature Analysis
algorithms to sample four bands of audio
instead of one or two like most other detectors. Digital Signal
Processing (DSP) is used to continuously sample and analyze
the sound. Within milliseconds after an audio "event" begins,
the microprocessor starts crunching data. Approximately 1200
comparisons and decisions are made before an event is reject-
ed or confirmed about 0.3 seconds later. Eight glassbreak sig-
nature models and four false alarm models, stored in memory,
are referenced during the confirmation process. The result of
this high-tech performance is more accurate glassbreak detec-
tion and improved false alarm rejection in tough environments.
TRI-GARD 555LS/557LS FEATURES
• Specified for plate, wired, tempered & laminated glass
• Microprocessor-based for better discrimination
• Advanced Signature Analysis™
• Signature Supervision
• Omnidirectional sensitivity
• Automatic sensitivity adjustments
TRI-GARD 555LS/557LS APPLICATIONS
• Glassbreak protection in residential, commercial
and industrial areas
• Protects plate, wired, tempered & laminated glass
• Omni direction detection to protect multiple windows
• Areas with closed drapes or blinds will reduce range.
Test with 517 tester for specific range
• Wall or ceiling mount installations
557LS

SPECIFICATIONS

S
ENSING
: Audio/air, open space (enclosed area)
R
ANGE
: 25' for plate, wired, tempered & 20' for laminated
glass. These ranges are for 1' X 1' minimum glass size. For
glass size down to 6" X 10" the range would be reduced by
1/2.
G
S
LASS
IZE
: Above stated range is for 1' X 1'
T
HICKNESS
: Plate-
3
¼
" to
32
Tempered–
1
¼
" to
1
¼
"
8
2
Wired–
1
¼
"to
4
Laminated–
¼
" to
¼
"
1
1
4
2
S
F
ENSING
IELD
: Omni-directional
S
ENSOR
: Electret condenser (F.E. T . pre-amp)
O
V
PERATING
OLTAGE
: 10–16 VDC filtered and regulated
P
C
OWER
ONSUMPTION
: 30 ma @13.6 VDC normal, 40 ma @
16 VDC.
O
T
PERATING
EMPERATURE
S
T
TORAGE
EMPERATURE
: -13° to 185° F (-25° to 85° C)
R
A
T
ELAY
CTIVATION
IME
: 3 seconds
A
LED: Latch or auto reset
LARM
A
R
LARM
ELAY
: SPDT (Form-C)- contacts .1Amp @30 VAC/24
VDC Relay is energized upon power up (C & NC are closed)
T
C
AMPER
IRCUIT
: Normally closed switch-contacts 50
milliamps @ 30 VAC/24 VDC.
V
M
OLTAGE
ONITOR
: Low or no voltage causes alarm relay to
open. Low voltage <10 VDC causes red LED to flash slowly
I
NSTALLATION
: Hardwire 6 wires including 2 for tamper
Testing: Follow instructions & test once a year
M
OUNTING
: Surface– screw and anchors included
C
OLOR
: White or Cabin Brown
S
IZE
: 3" x 3" x
3
¼
"
4
NOTE 1: The use of mini-blinds, shades, drapes* and sun film* can
reduce the range of the detector by 50%. Since room acoustics and win-
dow coverings can vary considerably, all detector installations should be
checked with the 517 tester.
* Not for sound deadening drapes
* Tested w/ 3M sun film #SH2CLAR (3M is a trademark of 3M Company)
1
¼
"
2
1
¼
"
2
: 14° to 120° F (-10° to 49° C)

Advertisement

loading

Summary of Contents for IEI Technology TRI-GARD 555LS Signature Series

  • Page 1: Specifications

    555LS/557LS Signature Series TRI-GARD ™ A u d i o G l a s s b r e a k D e t e c t o r s SPECIFICATIONS ENSING : Audio/air, open space (enclosed area) ANGE : 25’ for plate, wired, tempered & 20’ for laminated glass.
  • Page 2: Mounting Locations

    MOUNTING LOCATIONS CEILING MOUNTING The Tri-Gard can be mounted on any type of ceiling or wall. Mount the 555LS/557LS in any location on the ceiling which is in direct line of sight of the glass to be protected. The detector should be no closer than 4 feet from the glass to be protected.
  • Page 3: Installation Options

    Remote Test Mode with 517 Tester: To test remotely with 517 tester move DIP switch 1 to the on position. Step back about 10 feet from the detector and press 555LS the tester “To Test” button. The detector should now enter test CIRCUIT mode indicated by the slowly blinking green LED.
  • Page 4 cies that are present in glass break and can be used to reset gized (common and normally closed will be open). the unit. Notice that while clapping will reset the Signature CAUTIONS Supervision, it will not cause an alarm because it does not meet other criteria that the microprocessor is using to determine a •...

This manual is also suitable for:

Tri-gard 557ls signature series