INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS IMPORTANT INFORMATION Warnings Installation Instructions Wiring Instructions Outdoor Installation Maintenance Instructions APPLICATION INFORMATION Mounting Instructions Typical Wiring (Schematics) General Notes Areas Covered (Table) Location Suggestions PARTS LIST Parts List...
WARNINGS READ ALL INSTRUCTIONS BEFORE USING HEATER Unit may be a source of possible shock. NEVER attempt to service heater without disconnecting its power source. Source of possible ignition. CAUTION High Temperature, risk of fire, keep electrical cords, drapery, furnishings and other combustibles at least 3 feet (0.9m) from the front of heater and away from sides and rear.
INSTALLATION INSTRUCTIONS This heater must be permanently installed and hard wired by a licensed electrician in accordance with local electrical codes. Assembly procedure must be performed with no electrical power to unit. Step 1: Check UL/CE label on heater for proper voltage. Step 2: Follow supplied wiring instructions WIRING INSTRUCTIONS The heater is drilled and threaded for standard 1/2"...
BRACKET SPACING Heater can also be hung in a horizontal position using chains or MODEL MINIMUM SPACING BETWEEN BRACKETS custom brackets. Heater must be level, but can be rotated around SL 16XX 12" its horizontal axle. SL 24XX 20" SL 30XX 30"...
SNUG TO CERAMIC GENERAL NOTES 1. INFRATECH QUARTZ TUBE ELECTRIC HEATERS are furnished with wall/ ceiling mount swivel brackets. These brackets may be discarded when the heater is hung with chains or other special bracketing. 2. See sales literature and price list for full listing of models, descriptions, amperages, and voltages. At times, especially when the mounting height must be quite low, an increased number of smaller heaters can help prevent overheating.
Page 6
REPLACEMENT PARTS Need help? To order replacement PART NUMBER PART DESCRIPTION QUANTITY elements for your Infratech 13-7004, 13-7002, 13-7000 Body Reflector Set (SL 16/24/30/40) heating system, please contact us via phone or visit the auto- 13-7008 End Reflector motive section of our website.
LOCATION SUGGESTIONS Unless heaters are installed over 12 ft. high, it is generally recommended that all radiant heaters be mounted on an angle to assure that radiant warmth is distributed from the sides rather than straight down on the heads and shoulders of the people being warmed.
(i.e. cleaning products improperly applied). Warrantor is not responsible for consequential or incidental damages. Under no circumstances shall INFRATECH or any of its representatives be held liable for injury to any person or damage to any property, however arising.