Thank you for choosing HandyHeat 132, a programmable
thermostat, that provides both energy savings and total
comfort.
Install the Control Module
Align the bracket tabs on the control module with the
holes located on top of the power base.
This control module must be installed on a PB130
series power base.
Control module
Air vents
Air vents
Power base
Note: Keep the thermostat's air vents clean and free
from obstructions.
Note: The screw cannot be removed completely.
HandyHeat 132 Description
DAY/HOUR/MIN - Set the day and clock setting.
PGM - Program the schedule (programs).
MODE - Select the operating mode.
RETURN - To exit a function.
To configurate temperature setpoints:
,
Comfort
Economy and
Vacation.
Adjust the floor temperature (AF only).
—Increase and decrease temperature.
—Indicates the number of the current
program when Automatic mode is enabled.
Current operating mode (auto
/ manual
). In
Auto mode , the program's associated setpoint is
also displayed (
).
Indicates the room or floor temperature.
Heating indicators ( see "Temperature Control"
below).
First Power ON
On the first installation , the screen displays:
0:00, MO,
and temperature (room/floor).
For Floor Heating Installations:
One of the two following messenges may be
displayed when a problem occurs:
LO: The floor temperature is below 0°C,
the temperature sensor is defective, or not
connected.
The heating indicator
is displayed and
the relay is closed ( energized ).
HI: The floor temperature is above 60°C,
or the temperature sensor is defective.
Set the Time and Day
Set the time (HOUR - MIN).
Set the day (DAY).
If you remove the module from its base for more than
2 hours, the time and day will have to be reprogrammed.
Model Overview
HandyHeat 132-A
This model has been designed to control a room's ambi-
ent temperature.
The HandyHeat 132-A has one temperature sensor loca-
ted in the control module.
HandyHeat 132-AF
This model is designed to use a floor sensor to control
the room temperature.
The HandyHeat 132-AF has two temperature sensors:
- The first one, installed in the control module, controls
the ambient temperature.
- The second one, installed in the floor (and connected
to the power base), limits the temperature of the floor
(the default setting of this limit is 28°C).
HandyHeat 132-F
This model is designed to control floor heating systems.
The HandyHeat 132-F has a temperture sensor installed
in the floor (sensor is connected to the power base).
Adjust the Temperature Setpoints
Comfort
and Economy
Setpoints.
These setpoints are associated with the schedule's pro-
grams (programs 1 &3 = Comfort, programs 2 & 4 = Eco-
nomy) and are preprogrammed as follows:
A & AF mode is -
20°C,
18°C
F mode is -
28°C,
20°C
To modify a setpoint:
Set the temperature using
and press and hold
the
or
button until it is displayed on the
screen. Press MODE/RETURN to exit.
Vacation Setpoint
The vacation setpoint is associated to the Vacation opera-
ting mode and is preprogrammed to 10°C. To modify this
setpoint, repeat above step.
Floor Temperature Setpoint (AF mode only)
The floor temperature limit is preprogrammed to 28°C to
avoid damage to your floor.
To modify, press the adjustment button (below ) using a
pointed object, set the desired temperature using
press MODE/RETURN to exit.
Configure the Switches
HandyHeat 132 has two switches, located on the
upper-left part on the rear of the control module,
which are used to set the following options:
Early Start
When the Early Start function is enabled disabled
by default), HandyHeat 132 calculates the optimum
system start time to obtain the desired temperature
by the set time. To enable function:
Position switch #1 down.
Note: When this function is enabled,
the system can be activated before
the program's start time.
Temperature Display
By default, HandyHeat displays the temperature in °C.
If you wish to change to °F.
Position switch #2 down.
Note: When you switch from °C to °F or vice
,
versa, the
and
setpoints must be
redefined.
Select the Operating Mode
HandyHeat 132 offers three operating modes:
Automatic
- Executes the schedule.
Press MODE to select
. The current prog-
ram number is displayed.
You can temporarily pass the current prog-
ram by setting a specific temperature setpoint using
or by selecting one of the pre-defined setpoint
buttons
. The new setpoint will be maintained
(
)
until the beginning of the next program.
Manual
- Maintains constant temperature.
Press MODE to select
.
Set temperature
or selsct one of the pre-
defined setpoint buttons (
).
Vacation
- Maintains the Vacation setpoint
during a prolonged absence.
Press
.
and
DVK-00079-001

Advertisement

loading

Summary of Contents for HandyHeat 132 A

  • Page 1: Control Module

    Model Overview Configure the Switches Control Module HandyHeat132 A/F/AF HandyHeat 132 has two switches, located on the HandyHeat 132-A DAY/HOUR/MIN - Set the day and clock setting. upper-left part on the rear of the control module, PGM - Program the schedule (programs).
  • Page 2 DVK-00079-001...
  • Page 3: Technical Specifications

    This product is guaranteed against workmanship defects for a two-year period Lundagervej 102 following the initial date of purchase. During this period HandyHeat will repair DK-8722 Hedensted or replace, at our option and without charge, any defective product which has Denmark been used under normal conditions.

This manual is also suitable for:

132 af132 f