Download Print this page

Knoll PRM150 Installation Instructions Manual

Knoll systems advanced power conditioners installation instructions

Advertisement

Quick Links

PRM150, PRM200
Advanced Power Conditioners
Installation Instructions v1.1
Warning: To be installed and/or used in accordance with appropriate electrical
codes and regulations
Introduction: Thank you for your purchase of a Knöll PRM150 or PRM200 Advanced
Power Conditioner and congratulations on your choice. This specially made
conditioner is designed specifically to reduce noise and hum pickup by sensitive
equipment when ultra-low-noise is a must as well as surge suppression to protect
your valuable electronics.
FEATURES:
PRM150 rated for 15 amps, PRM200 rated for 20 amps (with special power
plug)
Push button or 4-24 VDC trigger power on/off
2210 Joules surge protection
Eight rear panel, heavy duty AC outlets includes two unswitched, and six
sequence delayed switched outlets with Digital Isolated Outlets
Main power cord is a 10 foot, ultra heavy duty 14 Ga. (PRT200 8 foot 12 ga.)
for easy access to a wall socket
Rear panel cable TV connectors for surge protection and noise filtering with
satellite or cable TV
One rack space
ADVANCED SURGE SUPPRESSION- Edge-of-the-art two level suppression with
an astounding 2210 Joules of lightning protection (most current competitive units
only have 360) in the AC power line! Add the cable TV, satellite dish and telephone
line protection and you have 3590 joules of total protection!
In the event the unit does not power up after a surge, a small internal board
replacement may be all it takes to keep on protecting your sound and picture quality
as well as your investments.

Advertisement

loading

Summary of Contents for Knoll PRM150

  • Page 1 Warning: To be installed and/or used in accordance with appropriate electrical codes and regulations Introduction: Thank you for your purchase of a Knöll PRM150 or PRM200 Advanced Power Conditioner and congratulations on your choice. This specially made conditioner is designed specifically to reduce noise and hum pickup by sensitive equipment when ultra-low-noise is a must as well as surge suppression to protect your valuable electronics.
  • Page 2 The PRM150 and PRM200 have two outlets on all the time. When the power up command has been received (by the trigger or the power button on the front panel) two more outlets turn on, two seconds later the last 2 (of eight total) outlets turn on.
  • Page 3: Installation

    We suggest that a dedicated 15-amp breaker be installed at the breaker box for use with the PRM150. It is best if the PRM150 or PRM200 is located with other equipment so that extension cords are not required. Heat is not a consideration when placing the power conditioner.
  • Page 4 If multiple amplifiers are too powerful to connect to a single Knoll power conditioner, we suggest using a 12V DC wall wart power supply connected to the Delay Max outlet on the power conditioner and connect the wall wart to the amplifier trigger input(s).
  • Page 5 Fuses There is a single slow blow 15-amp fuse in the PRM150 and there is a single 20 amp slow blow fuse in the PRM200. As per safety regulations, only authorized and experienced service people, including Knoll factory personnel are authorized to change these fuses. DO NOT CHANGE these fuses for safety reasons.
  • Page 6: Warranty

    PRM150 and PRM200 SPECIFICATIONS Current rating: PRM150 15 amps (1800 watts at 60/120 VAC, 60 HZ) fuse protected. PRM200 20 amps (2400 watts at 60/120 VAC, 60 HZ) fuse protected. Voltage Ranges: 90-135 VAC 60 Hz Remote trigger voltage: 3-24 VDC (input impedance 1k ohm)