Download Print this page

Lennox HEALTHY CLIMATE WB2-12 Operating Instructions

Healthy climate 504,880m 12/2003

Advertisement

Quick Links

OPERATING INSTRUCTIONS FOR MODELS WB2-12, WB2-17, WB2-17A, WP2-18 & WP2-18A
Introduction
Thank you for your recent Lennox Healthy Climate
chase. We sincerely appreciate your business and are pleased to
add your name to our growing list of customers. Now, please take a
few minutes and read this booklet. This will familiarize you with the
benefits you will receive from the equipment you just purchased
and help you understand the routine maintenance that will be
required.
Electrical Shock Hazard
Can cause injury or death.
Disconnect all electrical power supplies before
servicing.
Shut off water supply before disconnecting or
tapping into any water supply line.
CAUTION
Risk of Equipment Damage
After humidifier installation is completed, turn water supply
back on.
Principle of Operation
You have purchased a humidifier that operates on the evaporative
principle. It will provide the proper relative humidity (see operating
instructions) all during the heating season. It is very possible that
you have questions concerning what your new humidifier can do for
you, and what you should do to receive maximum benefits from it.
This booklet is intended to answer these questions.
The humidifier operates in conjunction with the furnace blower
motor. When the humidistat calls for humidity and the blower motor
is operating, water flows to the distribution pan located at the top of
the unit. The water is uniformly distributed across the width of the
pan and through a scientifically designed system of outlets. It flows
by gravity over the evaporative media. Dry, hot air is moved through
the moisture-laden evaporative media where evaporation takes
place. The now-humidified air carries moisture in vapor form
throughout the home.
Includes Safety, Operating, and Maintenance Instructions
®
Humidifier pur-
WARNING
Humidifiers
504,880M
12/2003
Risk of Equipment Damage
Do not use the saddle valve to regulate water flow.
It is designed to be completely opened or closed.
The correct water flow is determined by an orifice in each unit.
When the unit is operating, there will be a small, steady stream of
water to drain, which flushes away most of the trouble-causing
minerals.
The minerals and solid residue (white dust) not trapped by the
replaceable evaporative media are flushed down the drain. The
drain also eliminates the problems caused by stagnant water. This
is the most effective and least expensive method to dispose of trou-
ble-causing minerals.
Trouble-free performance and minimum maintenance are assured
by the design features of the Lennox Healthy Climate
unit housing parts that come in contact with water are non-metal
and will never rust or corrode. Neither heat nor water will affect
them under normal operating conditions.
The evaporative media, designed especially for uniform, high evap-
oration, and the scale control insert also efficiently trap mineral
deposits which are often the cause of damage to working parts in
ordinary humidifiers. When properly maintained, no "white dust"
will be distributed through the living quarters. The evaporative
media must be in good condition to assure high capacity trouble-
free performance. It should be changed at least annually.
The granular coating in the bottom of the distribution tray is
designed to provide equal distribution of water to each of the open-
ings assuring an even flow of water over the evaporative media. Do
not clean the mineral scale off the bottom of the water distribution
tray. The scale provides an excellent track for the water to follow.
This is actually what we try to simulate with the synthetic coating in
the bottom of the tray. If the coating is removed, it is not necessary
to purchase a new distribution tray. You can accomplish the same
uniform performance by applying a small amount of liquid dish soap
over the entire lower surface of the water distribution tray. This will
allow the water to flow evenly through each of the openings.
1
HEALTHY CLIMATE
HUMIDIFIER
CAUTION
®
®
Humidifier. All

Advertisement

loading

Summary of Contents for Lennox HEALTHY CLIMATE WB2-12

  • Page 1 Humidifiers HEALTHY CLIMATE ® 504,880M 12/2003 HUMIDIFIER OPERATING INSTRUCTIONS FOR MODELS WB2-12, WB2-17, WB2-17A, WP2-18 & WP2-18A Includes Safety, Operating, and Maintenance Instructions Introduction CAUTION Thank you for your recent Lennox Healthy Climate ® Humidifier pur- Risk of Equipment Damage chase.
  • Page 2: Operating Instructions

    Operating Instructions Automatic Humidifier Controls (Humidifier Models WB2-12, WB2-17 & WP2-18) Humidifier Models WB2-17A & WP2-18A) Your new Lennox Healthy Climate ® Humidifier is controlled by a Your Humidifier is now controlled by the Automatic Humidifier manual humidistat installed either in the living area or in the cold air Control which offers two modes of operation.
  • Page 3: Effect Of Water Characteristics

    Generally, the furnace blower motor must be operating for the The Automatic Humidifier Control will accurately control the humid- Lennox Humidifier to function. After the humidifier has operated for ity in your home to a maximum of 45% RH and a minimum of 10% one minute and water is entering the unit and coming out at the RH.The values of outdoor temperature and dial settings may fall in...
  • Page 4: Annual Maintenance

    II. Required Maintenance (Humidifier Models WB2-12, WB2-17 & WP2-17A) For best performance, you should replace the evaporative media in your humidifier at least annually. • Call your Lennox dealer for preventative maintenance and replacement components. Annual Summer Shutdown 1. Front Cover FOR THE SUMMER HUMIDIFIER SHUTDOWN, SIMPLY TURN THE 2.
  • Page 5 4. Unlatch humidifier cover assembly (1) from base assembly (2) at (Part No. 52P66 for Model WB2-12 and Part No. 59P94 for Model the bottom of the cover, lift, and set aside.