Caspian 60, 90 & 120 Series
Fan Convector
Installation & User Guide
Dear Installer,
Thank you for installing our products, we hope it gives many years of service;
In the event of items missing or visible damage please contact our After Sales Service on
01245 324560.
We would be most grateful if you would leave this Installation & User Guide and the
Guarantee Registration Card with the owner.
Thank you for your co-operation
Steve Russell
Customer Service Manager

Advertisement

loading

Summary of Contents for Smith's Heating First Caspian 60

  • Page 1 Caspian 60, 90 & 120 Series Fan Convector Installation & User Guide Dear Installer, Thank you for installing our products, we hope it gives many years of service; In the event of items missing or visible damage please contact our After Sales Service on 01245 324560.
  • Page 2 Introduction These heaters are primarily intended for installation directly onto a wall at low level. We recommend that this heater is stood on the floor and fixed to the wall. They must not be installed in bathrooms or other high humidity areas. Please contact us on 01245 324900 for details of products suitable for these applications.
  • Page 3 2. Fix the product to the wall using appropriate fixings for the wall type. Refer to the diagram & table below for the fixing-hole positions. 3. Connect the heating system flow and return pipes to the heater pipe work. Do not use soldered fittings to the heater pipe work as the heat generated could damage internal wiring and components.
  • Page 4 5. Isolate the electrical supply and connect the heater electric cable to the fused spur (3 amp). The fused spur must not be directly above the heater and must be accessible after the installation is complete. 3 AMP FUSED SPUR 6.
  • Page 5: Fault Finding

    8. Please leave this Installation & User Guide with the user for future reference Heat Output Performance Heat Heat Heat Output Output Output Model (kW) (kW) (kW) High Medium Caspian 60/03 Caspian 60/04 Caspian 90/06 Caspian 90/07 Caspian 120/10 11.4 10.4 Caspian 120/11 12.2 11.4 Caspian 120/12 13.1 12.2 10.4...
  • Page 6 Smith's Environmental Products Ltd., Blackall Industrial Estate, South Woodham Ferrers, Chelmsford, Essex CM3 5UW Tel: 01245 324900 After Sales: 01245 324560 Fax: 01245 324422 E-mail: info@smiths-env.com Web: www.smiths-env.com In light of our policy of continuous development Smith’s Environmental Products Ltd reserve the right to alter specifications without prior...
  • Page 7: User Guide

    Caspian Fan Convector User Guide Dear Customer We are delighted you have chosen our products and trust you are satisfied with the installation. We would ask you to take a few minutes to read through this User Guide. This will help you gain maximum benefit from your heater. As with all our products your heater is covered by a free five-year parts &...
  • Page 8 After Sales Service on 01245 324560. It will be helpful if you do not disconnect the heater from the central heating system. Smith's Environmental Products Ltd., Blackall Industrial Estate, South Woodham Ferrers, Chelmsford, Essex CM3 5UW Tel: 01245 324900 After Sales: 01245 324560 Fax: 01245 324422 E-mail: info@smiths-env.com Web: www.smiths-env.com...

This manual is also suitable for:

Caspian 120Caspian 90Caspian 60/03Caspian 60/04Caspian 90/06Caspian 90/07 ... Show all