Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
This package includes:
Lamp Holders
Cover
Plate
Sensor
Light Control

Requirements

• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
• Some codes require installation by a qualified elec-
trician. Please check the codes in your area.
• This product is intended for use with a junction box
marked for use in wet locations.
• The backplate has knockouts so the sensor can be
mounted on most junction boxes.
• In some applications a universal adaptor plate may
be needed. Adaptors are available at home centers
and electrical supply stores.
compliant
®
4 Mounting
Screws (2 sizes)
Gasket
2 Wire
Connectors

OPERATION

Mode:
On-Time:
Test
5 Sec
Normal
1, 5, 10 min.
Manual
Until Dawn*
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
the circuitry to calibrate.
TEST
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
AUTO
Put the ON-TIME switch in the 1, 5,
or 10 minute position.
MANUAL MODE
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.

Mode Switching Summary

TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
Works:
Day
Night
x
x
x
x
/
minutes for
1
2
ON-TIME
10 5 1 TEST
ON-TIME
10 5 1 TEST
1 Second OFF
then...
... back on.
Move ON-TIME Switch to
1, 5, or 10 minutes
Flip light switch off
for one second then
back on*
598-1284-00

Advertisement

Table of Contents
loading

Summary of Contents for NOMA 52-4075

  • Page 1 Security Light with Motion-activated Sensor This product is ENERGY STAR when used with 120 Watt bulbs. Models 52-4075 / 52-4076 Installation and Operating Instructions Features • Turns on lighting when motion is detected. • Automatically turns lighting off. • Photocell keeps the lighting off during daylight hours.
  • Page 2 INSTALLATION For easy installation, select an existing light operated by a wall switch for replacement. For best performance, mount the fixture about 8 feet (2.4 m) above the ground. ❒ Drill the holes needed to mount the backplate to the junction box. Eave Mount For under eave installation, the sensor head must be rotated as shown in the next two steps for proper...
  • Page 3: Test And Adjustment

    TEST AND ADJUSTMENT ❒ Turn on the circuit breaker and light switch. NOTE: Sensor has a 1 minute warm up period before it will detect motion. When first turned on, wait 1 minutes. ❒ Turn the SENSITIVITY (SENS) control to the mid posi- tion and the ON-TIME control to the TEST position.
  • Page 4: Troubleshooting

    TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE Lights will not come 1. Light switch is turned off. 2. F l o o d l i g h t i s l o o s e o r burned out. . Fuse is blown or circuit breaker is turned off.
  • Page 5 Lampe de sécurité à détecteur de mouvement Ce produit est conforme à ENERGY STAR lorsqu’il est utilisé avec des ampoules de 120 watts. Modèles 52-4075 / 52-4076 Instructions d'installation et mode d'emploi Caractéristiques • Allume l’éclairage lorsqu’un mouvement est détecté.
  • Page 6 INSTALLATION Pour faciliter l’installation, choisir un appareil d’éclairage devant être remplacé et qui est déjà commandé par un interrupteur. Pour assurer un rendement maximal, monter l’appareil d’éclairage environ 2,4 mètres au-dessus du sol. ❒ Percez les trous nécessaires au montage de la plaque ar- rière à...
  • Page 7 ESSAIS ET RÉGLAGES ❒ Mettre en circuit le disjoncteur et l’interrupteur d’éclairage. NOTE: Le capteur doit se réchauffer 1 de pouvoir détecter le mouvement. Lorsque l’appareil est mis en circuit, attendre 1 minute. ❒ Tourner la commande de sensibilité (SENS) à la position intermédiaire et la commande de temps en circuit (ON-TIME) à...
  • Page 8 SYMPTÔME CAUSE POSSIBLE L’éclairage ne s’al- 1. L’interrupteur d’éclairage est hors lume pas. tension. 2. Le projecteur est dévissé ou brûlé. . Le fusible a sauté ou le disjoncteur a été déclenché. 4. Le dispositif de coupure pendant le jour fonctionne. (Vérifiez à nouveau à...