Installation
Instructions
Free-Standing
Electric Ranges
Questions?
Call 1.800.GE.CARES (1.800.432.2737) or visit www.GEAppliances.com
In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca
BEFORE YOU BEGIN
Read these instructions completely and
carefully.
° IMPORTANT
-- Save these
instructions for local inspector's use.
° IMPORTANT
--
Observe all
governing codes and ordinances.
Note to Installer-
Be sure to leave these
instructions
with consumer.
Note to consumer-
Keep these
instructions for future reference.
Skill level - Installation of this appliance
requires a qualified installer or electrician.
Proper installation is the responsibility
of the
installer.
Product failure due to improper installation is
not covered under warranty.
FOR YOUR SAFETY:
• All ranges con tip.
• BURNS or other SERIOUS
INJURIES con result.
• INSTALL and CHECK the
ANTI*TIP bracket
following
the instructions
supplied
with the bracket.
Anti-Tip Bracket
Kit Included
If you did not receive an anti-tip bracket with your purchase,
call 1.800.626.8774 to receive one at no cost. (In Canada,
call 1.800.561.3344.) For installation instructions of the bracket,
visit: www.GEAppliances.com.
(In Canada, www.GEAppliances.ca.)
-_ WARN ING
_
Before
beginning the installation, switch
power off at service panel and
lock the service disconnecting
means to prevent power from
being switched on accidentally.
When the service disconnecting
means cannot be locked,
securely fasten a prominent
warning device, such as a tag,
to the service panel.
MATERIALS
YOU MAY NEED
TOOLS
YOU WILL
NEED
Drill with 1/8" Bit
Tin Snips
Safety Glasses
Tape Measure
Adjustable Wrench
Pliers
Squeeze Connector
(UL Listed 40 AMP)
Level
1/4" Nut Driver
(For Conduit
4-Wire Cord 4' long OR
Installations
Only)
3-Wire Cord 4' long
REMOVE
PACKAGING
MATERIALS:
Failure to remove packaging
materials could result in damage to the appliance. Remove all packing parts from oven,
racks, heating elements and drawer. Also, remove protective film and labels on the outer
door, cooktop and control panel.
r_
PREPARE
THE OPENING
(FOR INDOOR
USE ONLY)
See illustrations for all rough-in and spacing dimensions.
The range may be placed with 0"
clearance (flush) at the back wall and side walls of the cabinet.
SINGLE OVEN
DOUBLE OVEN
On models with baking
or warming drawers,
electrical outlet must
not be in this area.
"
-_
_
45" /
\_
47%" Acceptable electrical outlet area.
/
_
Orient electrical receptacle so the
.z_f
length is parallel to floor.
....................
* GE-branded models have control
panels 30%" wide.
NOTE: Use a 4' power cord to prevent interference
with the storage drawer. Power cords 4_' to 6' long
may have to be dressed to allow for proper drawer
closing.
MINIMUM
DIMENSIONS
BETWEEN COOKTOP,
WALLS AND ABOVE THE COOKTOP:
A. Make sure the wall covering, countertop, flooring
and cabinets around the range can withstand
the heat (up to 200°F) generated
by the range.
B. Allow 30" minimum clearance between surface
units and bottom of unprotected
wood or metal
cabinet, or allow a 24" minimum when bottom
of wood or metal cabinet is protected by no less
than 1/4" thick flame retardant millboard covered
with not less than No 28 MSG sheet metal,
(.015"), .015" thick stainless steel, .024"
aluminum or .020" copper.
qOTE C
B
C
Both
Sides
C. This appliance has been approved for 0" spacing to adjacent surfaces above the cooktop.
However, a 6" minimum spacing to surfaces less than 15" above the cooktop and adjacent
cabinet is recommended
to reduce exposure to steam, grease splatter and heat.
To reduce the risk of burns or fire when reaching over hot surface elements, cabinet storage
space above the cooktop should be avoided.
If cabinet storage space is to be provided above
the cooktop, the risk can be reduced by installing a range hood that projects at least 5" beyond
the front of the cabinets. Cabinets installed above the cooktop must be no deeper than 13".
r_
ELECTRICAL
REQUIREMENTS
Z_WARNING:
This appliance must be properly grounded.
_, WARN
IN G:
All new constructions, mobile homes, recreational vehicles and installations
where local codes do not allow grounding through neutral, require a 4-conductor UL-listed range cord.
,_ WARNING:
To prevent fire or shock, do not use an extension cord with this appliance.
il, WARNING:
To prevent shock, remove house fuse or open circuit breaker before
beginning installation.
We recommend
you have the electrical wiring and hookup of your range connected by a qualified
electrician. After installation,
have the electrician show you how to disconnect
power from the
range.
You must use a single-phase,
120/208 VAC or 120/240 VAC, 60 hertz electrical system. If you
connect to aluminum wiring, properly installed connectors
approved for use with aluminum wiring
must be used.
Effective January 1, 1996, the National Electrical Code requires that new construction
(not
existing) utilize a 4-conductor connection
to an electric range. When installing an electric range
in new construction,
mobile home, recreational
vehicle, or an area where local codes prohibit
grounding through the neutral conductor, refer to the section on four-conductor
branch circuit
connections.
Check with your local utilities for electrical codes which apply in your area. Failure to wire your
oven according to governing codes could result in a hazardous condition. If there are no local
codes, your oven must be wired and fused to meet the National Electrical Code, NFPA No.
70 - latest edition, available from the National Fire Protection Association.
This appliance must be supplied with the proper voltage and frequency, and connected to an
individual, properly grounded,
40 amp (minimum) branch circuit protected by a circuit breaker
or time-delay fuse.
Use only a 3-conductor or a 4-conductor
UL-listed range cord. These cords may be provided with
ring terminals on wire and a strain relief device.
A range cord rated at 40 amps with 125/250 minimum volt range is required. A 50 amp range
cord is not recommended
but if used, it should be marked for use with nominal l_V diameter
connection openings. Care should be taken to center the cable and strain relief within the
knockout hole to keep the edge from damaging the cable.
The rating plate is located on the oven frame or on the side of the drawer frame.
Rating plate /
Rating
SINGLE OVEN
DOUBLE OVEN
POWER CORD AND CONDUIT INSTALLATION
r_
Remove wire cover (on the back of range) by removing screws using a 1/4" nut driver. You
can access the terminal block by either removing a terminal block cover (on some models)
or the wire cover. Do not discard
these screws.
Back of range
5 screws to
,,move
wire cover
Wire cover
For power cord and 1" conduit only, remove
the knockout ring (1%") located on bracket
directly below the terminal block. To remove
the knockout, use a pair of pliers to bend the
knockout ring away from the bracket and
twist until ring is removed.
Terminal block
(app
may vary)
Knockout
ring in
bracket.
Knockout ring
removed
Back of range
z::_
_::::
&
Screw to
remove
terminal
block cover
r-eq
Terminal block cover
For power cord installations
only
(see the next step if using conduit),
assemble the strain relief in the hole.
Insert the power cord through the strain
relief and tighten. Allow enough slack
to easily attach the cord terminals to
the terminal block. If tabs are present at
the end of the winged strain relief, they
can be removed for better fit.
NOTE: Do not install the power cord
without a strain relief. The strain relief
bracket MUST be installed before
reinstalling the rear range wiring cover.
Strain relief
Terminal
block
Bracket
@
For 3/4" conduit
installations
only, purchase a squeeze connector matching the diameter
of your conduit and assemble it in the hole. Insert the conduit through the squeeze connector
and tighten. Allow enough slack to easily attach the wires to the terminal block. NOTE: Do not
install the conduit without a squeeze connector. The squeeze connector
MUST be installed
before reinstalling
the rear range wiring cover.
Squeeze
__
_1
connector
-_,1_[-
Terminal block
Conduit __
_'qr
Bracket
PROCEED TO STEP 5 OR 6.
r_
3-WIRE INSTALLATION
tLWARNIN G:
The neutral or ground wire of the power cord must be connected
to the neutral terminal located in the center of the terminal block and the ground strap must
connect the neutral terminal to the ground plate. The power leads must be connected to the
lower left and the lower right terminals of the terminal block.
DO NOT remove
the ground strap connection.
FOR POWER CORD INSTALLATION
A. Remove the 3 lower terminal screws from the terminal block.
B. Insert the 3 terminal screws through each power cord terminal ring and into the lower
terminals of the terminal block. Be certain that the center wire (white/neutral)
is connected
to the center lower position of the terminal block.
C. Tighten screws securely into the terminal block.
FOR CONDUIT INSTALLATION
A. Loosen the 3 lower terminal screws on the terminal block. Strip wire to exposed tip about 5/8" long.
B. Insert the center (white/neutral) wire tip through the bottom center terminal block opening.
On certain models, the wire will need to be inserted through the ground strap opening
and then into the bottom center block opening. Insert the two side bare wire tips into
the lower left and the lower right terminal block openings.
C. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not over-tighten
the screws.
NOTE: ALUMINUM
WIRING: Aluminum building wire may be used but it must be rated
for the correct amperage
and voltage.
Power Cord
Terminal block
(appearance
may vary)
Neutral terminal
Ground stra
Ground
plate
(_
Power cord
Conduit
Terminal __=__
block
_,_
Wire tips-----__
I
Conduit
_-] _
I
PROCEED
TO STEP 7.
31-10677-1
03-09
JR
[_
4-WIRE INSTALLATION
Ai,WAR NI NG:
The neutral wire of the supply circuit must be connected to the neutral terminal
located in the lower center of the terminal block. The power leads must be connected to the lower left and the
lower right terminals of the terminal block. The grounding lead must be connected to the frame of the range
with the ground plate and the green ground screw.
FOR POWER CORD INSTALLATION
A. Remove the 3 lower terminal screws from the terminal block. Remove the ground screw and
ground plate and retain them. Cut and discard the ground strap. DO NOT DISCARD ANY SCREWS.
B. Insert the one ground screw into the power cord ground wire terminal ring, through the ground plate
and into the frame of the range.
C. Insertthe 3 terminal screws (removed earlier) through each power cord terminal ring and into the lower
terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to the center
lower position of the terminal block. Tighten screws securely into the terminal block.
FOR CONDUIT INSTALLATION
A. Loosen the 3 lower terminal screws on the terminal block. Remove the ground screw and ground plate
and retain them. Cut and discard the ground strap. DO NOT DISCARD ANY SCREWS. Strip wire
to exposed tip about 5/8" long.
B. Insert the ground bare wire tip between the range frame and the ground plate (removed earlier)
and secure it in place with the ground screw (removed earlier). Insert the bare wire (white/neutral) tip
through the bottom center of the terminal block opening. Insert the two side bare wire tips into the lower
left and the lower right terminal block openings.
C. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not over-tighten the screws.
NOTE: ALUMINUM
WIRING: Aluminum
building wire may be used but it must be rated
for the correct amperage and voltage.
Before-Power
Cord and Conduit
Terminal.____i_
_x_
Ground strap
block
___
_or
_
Ground f
_
\
strap
Neutral
terminal
After-Power
Cord
/
\
Terminal---_
block
Ground ""avl
Neutral
terminal
__
Ground plate
(grounding
to
range)
After-Conduit
round
block
_
_atoeu nding
to range)
tips
.,,_,._
Ground screw _ " _£_=_--_I
[_
REPLACE THE WIRE COVER
Replace wire cover on range back by sliding its left edge under the retaining tabs and replace
the screws removed earlier. Make sure that no wires are pinched between cover and range back.
Back of range
5 screws to
wire cover
Back of range
=_
'_ -
_
Screw to
remove
_
_
terminal
=1
_
_
__
_ block cover
Terminal
0,ockcover
r-_
ANTI-TIP
DEVICE INSTALLATION
To reduce the risk of tipping the range, the range must
be secured by a properly installed anti-tip bracket. See
installation instructions shipped with the bracket for
complete details before attempting to install.
All rangescon tip.
TO check if the bracket is installed and engaged properly,
BURNS o r other SERIOUS
remove the storage drawer or kick panel and look
INJURIES con result,
underneath the range to see that the leveling leg is
INSTALL ondCHECK t he
engaged in the bracket. On models without a storage
ANTI-TIP brocketfollowing
drawer or kick panel, carefully tip the range forward.
the instructionssupplied
The bracket should stop the range within 4 inches. If it
with the bracket,
does not, the bracket must be reinstalled. If the range
is pulled from the wall for any reason, always repeat this
procedure to verify the range is properly secured by the anti-tip bracket. Never completely remove
the leveling legs or the range will not be secured to the anti-tip device properly.
r_
LEVEL THE RANGE
Z_WARN IN G:
Never
completely remove
the leveling leg
as the range will not be secured to the anti-tip device properly.
MODELS WITH STORAGE DRAWER OR KICK PANELS
@
Plug in unit and slide into place. Pull drawer out until it stops.
Lift front of drawer until the stops clear the guide. Remove the drawer.
Install the oven shelves in the oven and position the range where
it will be installed.
Check for levelness by placing a spirit level on one of the oven
shelves. Take two readings--with
the level placed diagonally first
in one direction and then the other.
F_
The front leveling legs can be adjusted from the bottom
and the rear legs can be adjusted from the top or the bottom.
F_
Use an adjustable wrench to adjust the leveling legs until
the range is level.
r_
LEVEL THE RANGE (CONT.)
r_
Position cord so that it does not interfere with drawer.
Place drawer rail on guides. Push the drawer in until it stops.
r_
Lift front of drawer and push in until the stops clear
the guides.
Fi_
Lower the front of the drawer and push in until it closes.
J/_
Lower
Legele_
ge
MODELS WITH BAKING, WARMING DRAWERS OR DOUBLE OVEN
range
r_
Plug in the unit.
F_
Measure the height of your countertop at the rear of the opening (X).
r_
Adjust two rear leveling legs so that the rear of cooktop is at the same
height as the counter (Y).
F_
Slide unit into place.
F_
Install oven shelves in the oven and position the range where it will be installed.
F_
Check for levelness by placing a spirit level on one of the oven shelves.
Take two readings--with
the level placed diagonally first in one direction
and then the other.
r_
Adjust front leveling legs until the range is level.
iY
II!.11 FINAL INSTALLATION
CHECKLIST
• Check to make sure the circuit breaker is closed (RESET) or the circuit fuses are replaced.
• Be sure power is in service to the building.
• Check that all packing materials and tape have been removed. This will include tape on metal panel
under control knobs (if applicable), adhesive tape, wire ties, cardboard and protective plastic. Failure
to remove these materials could result in damage to the appliance once the appliance has been
turned on and surfaces have heated.
• Check that the door and drawer are parallel to each other and that both operate smoothly. If they
do not, see the Owner's Manual for proper replacement.
• Check to make sure that the rear leveling leg is fully inserted into the Anti-Tip bracket and that the
bracket is securely installed.
OPERATION
CHECKLIST
• Turn on one of the surface units to observe that the element glows within 60 seconds. Turn the unit
off when glow is detected. If the glow is not detected within the time limit, recheck the range wiring
connections. If change is required, retest again. If no change is required, have building wiring checked
for proper connections and voltage.
• Check that the Clock (on models so equipped) display is energized. If a series of horizontal red
lines appear in the display, disconnect power immediately. Recheck the range wiring connections.
If change is made to connections, retest again. If no change is required, have building wiring checked
for proper connections and voltage. It is recommended that the clock be changed if the red lines
appear.
• Be sure all range controls are in the OFF position before leaving the range.

Advertisement

loading

Summary of Contents for GE PB909DP5BB

  • Page 1 DOUBLE OVEN or the wire cover. Do not discard these screws. Questions? Call 1.800.GE.CARES (1.800.432.2737) or visit www.GEAppliances.com where local codes do not allow grounding through neutral, require a 4-conductor UL-listed range cord. Back of range Back of range In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca ,_ WARNING: To prevent fire or shock, do not use an extension cord with this appliance.
  • Page 2 S i hayleng_Jetas alfinaldelalivio BIoque terminal otras LESIONES GRAVES. * Los modelos de marca GE cuentan con neutral, consulte la secci6n sobre conexiones en circuito derivado de cuatro conductores. detensi6n con alas,estaspuedenquitarse para de evitar que el encendido se...

This manual is also suitable for:

Pb909sp6ssPb909tp6wwPb909dp6bbPb900sp5ssPb900dp5bbPb900tp5ww ... Show all