Line sharing device

Advertisement

Quick Links

VIKING
C O M M U N I C A T I O N & S E C U R I T Y S O L U T I O N S
A Smart Line Sharing Device with
Why
pay
for
a
elevator/emergency phone or alarm panel?
The
Line Sharing Device allows the user to
share an existing phone line with an emergency
phone or other priority alarm device. This can save
hundreds of dollars a year over leasing a dedicated
phone line. The
line or analog PABX/KSU station.
An outbound call on the
port takes priority over a call in progress on the
port. Any call in progress on the
port will be disconnected for 2 seconds, re-
turning dial tone to the
A busy signal is then sent to the
For incoming calls, the
tinctive Ring, or Quick Call Back. All other calls will
be routed to the
can be set up so that all inbound calls are routed
to the
ID is not passed through the LSD-2 to the devices.
• Routes both incoming and outgoing calls
• Allows an Emergency device to share a phone
line with other devices (fax machines, phones,
modems)
• Gives priority to the Emergency devices
• Incoming calls routed to one of two ports by
Caller ID, Distinctive Ring or Quick Call Back
• Status LED displays mode of operation
• Can store up to 12 Caller ID numbers
• Provides a busy signal to the phone port when
an Emergency device is in use
www.vikingelectronics.com
Information: (715) 386-8861
PRODUCT MANUAL
Inbound Switching Capability
dedicated
line
for
can be used on any C.O.
can route calls to the
port using Caller ID, Dis-
. Alternatively, the
port. Note: Caller
your
Important: When the emergency device is in use,
port.
the phone line is not available for normal use. Any
port.
additional emergency calls will have to be made
on another phone line. For this reason the LSD-2
is not recommended for single line applications.
Note: With some Central Office equipment, it may
take up to 20 seconds to disconnect an incoming
call to the non-priority device. The emergency de-
vice must be capable of delaying this long before
dialing.
Share an existing phone line with an emergency
device such as:
Emergency phones
Area of refuge phones
Alarm panels
ATM's
Card readers
Any device that needs instant access to a
phone line
120VAC / 12VDC 500mA UL listed adapter
provided
3.5" x 1.75")
with 5% to 95% non-condensing humidity
133mm x 89mm x 44mm (5.25" x
.9 kg (2 lbs)
0° C to 32° C (32° F to 90° F)
40V DC
6 screw terminals

Advertisement

loading

Summary of Contents for Viking LSD-2

  • Page 1 The emergency de- to the port. Note: Caller vice must be capable of delaying this long before ID is not passed through the LSD-2 to the devices. dialing. Share an existing phone line with an emergency device such as: •...
  • Page 2 Connect the Emergency Phone, Alarm Panel or other priority device to the terminal positions marked Connect the 12VDC wall adapter to the Note: Be sure the LSD-2 has power available at all times. If power is lost, the phone line will be connected to the pri- ority device only.
  • Page 3 Note: If more than 12 numbers are attempted to be stored, the LSD-2 will re-ring the DEVICE 1 port. If the Caller ID number is already stored in memory, the LED will not fast flash and the call will be automatically routed to the DEVICE 2 (PRI- ORITY) port.
  • Page 4 ID numbers. Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no responsibility for errors and omissions contained in this information. Revi- sions of this document or new editions of it may be issued to incorporate such changes.