Oil-fired water boilers

Advertisement

Quick Links

OWF
Oil-Fired
Water
Boilers
User's
Information
IVianual
Hazard
definitions
CAUTION
[ .OT,C I
Hazards
that will
cause
severe
personal
injury,
death
or substantial
property
damage.
Hazards
that can
cause
severe
personal
injury,
death
or substantial
property
damage.
Hazards
that will or can cause
minor
personal
in-
jury or property
damage.
Special
instructions
on installation,
operation
or
maintenance
that are important
but not related
to
personal
injury or property
damage.
The User's
Information
Manual
provides
information
to the boiler
owner/user
for routine operation
and maintenance
and emergency
shutdown.
Detailed
information
on boiler
installation,
operation,
start-up,
service
and parts
is included
in the Boiler
Manual.
The
Boiler
Manual
is intended
only for use by a qualified
installer/
service
technician.
i
INSTALLER
-- Please
take time to review this
User's Information
Manual with the boiler owner.
Explain all maintenance
and service
procedures.
Failure to adhere to the guidelines
on this page can result
in severe
personal injury, death or substantial
property damage,
At the beginning
of each
heating
season,
contact
your qualified
service
technician
to inspect,
clean
and start-up
the
boiler
per the Boiler
Manual.
Failure
to comply
could result
in boiler
failure,
leading
to potential
severe
personal
injury,
death
or substantial
property
damage.
Service
and maintenance
1.
To avoid electric
shock,
disconnect
electrical
supply
before
performing
maintenance.
2.
To avoid severe
burns,
allow
boiler to cool before
performing
maintenance.
3.
You must
maintain
the boiler
as outlined
in the manual
and
have the boiler started
up and serviced
at least annually
by a
qualified
service
technician
to ensure
boiler/system
reliability.
Boiler
operation
4.
DO NOT block flow of combustion
or ventilation
air to boiler.
If vent
or air blockage
is easily
accessible
and removable,
remove
it. If blockage
is not obvious
or cannot
be removed,
have
the boiler
and system
checked
by a qualified
service
technician.
5.
Should
overheating
occur or oil supply
fail to shut off, do not
turn off or disconnect
electrical
supply
to pump.
Instead,
shut
off the oil supply
at a location
external
to the appliance.
6.
DO NOT use this boiler
if any part has
been
under
water.
immediately
call a qualified
service
technician
to inspect
the
boiler
and to replace
any part of the control
system
and any
burner
control
that has been
under water.
7.
Have the building
monitored
when it is vacant
for an extended
period.
Safety
controls
can shut down the boiler at any time.
The
loss
of heat
can
result
in significant
damage
due to
freezing.
Air contamination
8.
Carefully
read and follow
instructions
on page
2.
Boiler
water
9.
DO NOT use petroleum-based
cleaning
or sealing compounds
in boiler
system.
Water
seal deterioration
will occur,
causing
leakage
between
sections
and damage
to heating
system
components.
This can result
in substantial
property
damage.
10. DO NOT use "homemade
cures"
or "boiler
patent
medicines".
Serious
damage
to boiler,
personnel
and/or
property
may
result.
11. Continual
fresh
makeup
water will reduce
boiler
life. Mineral
buildup
in sections
reduces
heat transfer,
overheats
cast iron,
and causes section
failure. Addition
of oxygen
and other gases
can cause
internal
corrosion.
Leaks
in boiler
or piping
must
be repaired
at once to prevent
makeup
water.
12. DO
NOT add cold water
to hot boiler.
Thermal
shock
can
cause
sections
to crack.
Glycol -- potential
fire hazard --
13. All glycol
is flammable
when exposed
to high temperatures.
If glycol
is allowed
to accumulate
in or around
the boiler
or
any other potential
ignition source,
a fire can develop.
In order
to prevent
potential
severe personal
injury, death or substantial
property
damage
from fire and/or
structural
damage:
Never store glycol
of any kind near the boiler or any potential
ignition
source.
Inspect
the boiler
and system
regularly
for leaks.
Have
any
any
leaks
repaired
immediately
to prevent
possible
accumulation
of glycol.
Never
use automotive
antifreeze
or ethylene
glycol
in the
system.
Using
these
glycols
can lead to hazardous
leakage
of glycol
in the boiler system.
Part Number 672 02 1005 00

Advertisement

loading

Summary of Contents for ICP OWB Series

  • Page 1 Oil-Fired Water Boilers User's Information IVianual Hazard definitions The User's Information Manual provides information to the boiler owner/user for routine operation and maintenance and emergency Hazards that will cause severe personal injury, shutdown. Detailed information on boiler installation, operation, death or substantial property damage.
  • Page 2 O_l,z]E_ 8_: O_v_Tl[" Oil-Fired Water Boilers - User's Information Manual Please read this page first Air contamination Start-up To prevent potential of severe personal injury or death, check for If burner does not fire, check for: products or areas listed in table below before installing...
  • Page 3 O_V]I_ O_v_i71 _ Oil-Fired Water Boilers - User's Information Manual Check monthly Periodically Oil motors equipped with oil cups Boiler and system piping Burner or circulator motors may require oiling. Such motors Visually inspect for leaks around piping, circulators, relief valve are fitted with oiling cups.
  • Page 4 O_l,Z]l_ O_v_F1 _ Oil-Fired Water Boilers - User's Information Manual Troubleshooting Troubleshooting Common problems and possible solutions ........i Symptom Common Causes Possi '_ble Corrections Rapid cycling - Thermostat installed where Locate thermostat on inner wall awayfrom heat sources or cool drafts. boiler turns on and drafts or heat affect reading off frequently...