National-Riverside
Universal
HEATERMODEL 80-FAP
MODELS 150-FAST
!
!
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS
HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE
FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING,
AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR
SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL,
LABELS, ETC. CONTACT THE MANUFACTURER.
RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
OPERATING INSTRUCTIONS
CONSTRUCTION
150,000 BTU/HR
YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS,
SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU
OPERATE THIS HEATER.
PROPANE
HEATER
FORCED AIR
Type of Gas
Input Rating
Fuel Consumption
Gas Supply Pressure
to Regulator
Regulator Out
Fuel Orifice Size
Electrical Input
Minimum Operating Voltage
Fan
Average Air Temp Rise
Ignition
Primary Flame Control
High Temperature Limit Control
Minimum Ambient Temp. Rating
Size (Length x Width x Height)
New Weight
Shipping Weight
SPC
ALL-PRO
MODEL SPC-150T
HEATER SPECIFICATIONS - 150
For Use with Propane Gas Only
150,000 BTU/hr
7 Lbs/hr
Max: Bottle Pressure
Min: 5 psig
11" W.C.
1.00 mm Drill - 18 Holes
115V, 60Hz 10, 4a
100V
3000 rpm, 450 cfm
Approx. 300
Direct Spark, Interrupted Type
Solid State, 10-15 second Timing
240
o
F
0
o
F
26" x 9" x 16"
32 lbs.
34 lbs.
o
F