Optional Return Temperature Control (RTC)
Sizes from 342,000 to 1,852,000 BTU/hr output
Commercial, Forced Draft
Commercial, Forced Draft
Hot Water or Steam Boiler
Hot Water or Steam Boiler
For Businesses, Institutions,
For Businesses, Institutions,
Apartments and other
Apartments and other
commercial buildings
commercial buildings
Heat exchanger constructed
and tested in accordance with
ASME Section IV standard.
Com
Com
or S
or S

Advertisement

loading

Summary of Contents for Crown 24 Series

  • Page 1 or S or S Commercial, Forced Draft Commercial, Forced Draft Hot Water or Steam Boiler Hot Water or Steam Boiler For Businesses, Institutions, For Businesses, Institutions, Apartments and other Apartments and other commercial buildings commercial buildings Cast iron sectional heat exchanger ■...
  • Page 2 Commercial Hot Water Commercial Hot Water or Steam Boiler or Steam Boiler Commercial, Forced Draft Commercial, Forced Draft Hot Water or Steam Boiler Hot Water or Steam Boiler Ten reasons why you need For Businesses, Institutions, For Businesses, Institutions, the Series 24 commercial boiler Apartments and other Apartments and other commercial buildings...
  • Page 3: Standard Equipment

    Top or rear flue outlet Front mounted with adjustable lock-type controls for easy damper includes adjustment and tapping for outlet maintenance pressure readings Left side jacket panels and cleanouts for easy access to all flue surfaces Tankless heater for domestic hot water Cast iron vertical flue design with...
  • Page 4 Series 24 Dimensions (in inches) MAXIMUM FLUTE BURNER BECKETT APPROX. NUMBER NUMBER NUMBER OF OUTLET MOUNTING K.D. BLR. BOILER OF STEAM HEATERS DIAMETER PLATE WIDTH CF OIL CG GAS SHIPPING MODEL SECTIONS ‘A’ ‘B’ RISERS ‘C’ ‘D’ ‘E’ ‘F’ ‘G’ ‘H’...
  • Page 5 Commercial Hot Water or Steam Boiler Commercial Hot Water or Steam Boiler Burner Mounting Plates and Adapter Plates Control Tappings BECKETT (“CF” SERIES) BURNER ADAPTER PLATE TAPPING SIZE LOCATION (IN.) STEAM BOILER WATER BOILER I.D. ‘A’ ‘B’ ‘C’ BOILER MODEL PART NO.
  • Page 6 Series 24 Minimum Piping Recommendations – Water Boiler SUPPLY Recommendation 1 is used when the load is constant and SUPPLY REAR OF not varied due to mixing or BOILER DRAIN VALVE REAR OF multiple zones. Use when: (SEE NOTE 4) BOILER DRAIN VALVE system return water is not...
  • Page 7 SUPPLY TEES DIVERTING VALVE & ACTUATOR SEE NOTE 5 SUPPLY BOILER CIRCULATOR RETURN (BY OTHERS - SEE NOTE 5) SEE NOTE 6 DRAIN VALVE (SEE NOTE 4) 3” x 12” NIPPLE AND BELL REDUCER (SEE NOTE 4) REAR OF BOILER RETURN Recommendation 3 RETURN...
  • Page 8 Commercial Hot Water or Steam Boiler Commercial Hot Water or Steam Boiler Series 24 Specifications BURNER HEATING WATER BOILER WEIGHT NET I=B=R RATING INPUT SURFACE PRESSURE CONTENT w/ WATER GROSS (SQ. FT.) FIREBOX (GAL.) (LBS.) VENT BOILER HORSE- OUTPUT SQ. FT. VOLUME FIREBOX DIA.