ITI 60-774 - Security SuperBus 2000 8-Zone Input Module Installation Instructions Manual

8-zone input module

Advertisement

Quick Links

Document Number: 466-1606 Rev. B
November 2000

Product Summary

®
Each SuperBus
2000 8-Zone Input Module adds eight
supervised hardwire zones. Each module includes mounting
hardware and eight 2.0K ohm end-of-line (EOL) resistors.
Power for the module is provided by the panel.
Both normally open and normally closed detectors can be
wired to module inputs. Using an EOL resistor on each loop
input, the module monitors all zones and alerts the panel if
there is an open/short circuit.
®
Advent
panels can support multiple modules for up to 250
®
zone inputs. UltraGard
panels can support up to eight
modules for 64 additional zone inputs. Concord
be expanded up to 76 zone inputs.
For additional security, the plastic case includes space for
installing a magnet and reed switch that can provide tamper
protection to detect cover removal.
SuperBus 2000 vs. SuperBus
SuperBus 2000 panels have the ability to auto-address mod-
ule unit numbers. When the panel is powered up, the panel
automatically reads the unique SuperBus 2000 device ID
number and assigns a unit number to the module. This elim-
inates manually setting DIP switches and the chance of
identical unit number conflicts.
SuperBus 2000 Panels
R
Advent
R
Concord (software versions 2.0 and later)
SuperBus panels communicate with SuperBus 2000 mod-
ules but require the module unit number to first be set man-
ually with DIP switches.
SuperBus Panels
R
UltraGard
R
Concord (software versions 1.0–1.6)

Module Components

panels can
SOFTWARE
VERSION LABEL
Figure 1. Module Circuit Board Components
Table 1. Module Component Descriptions
Component
Unit Number DIP
Switches
SuperBus 2000
Device ID Number
Label
Software Version
Label
Green POWER
LED
Red BUS LED
Wiring Terminals
8557109A.DS4
˜ÃÌ>>̈œ˜Ê˜ÃÌÀÕV̈œ˜Ã
UNIT NUMBER
DIP SWITCHES
Function
Used for manually setting unit
numbers (SuperBus panels).
Identifies unique device ID
number (SuperBus 2000
panels).
Identifies the installed
software version.
Indicates module power status.
Flashes to indicate normal
communication to the panel
bus.
Used for power, bus, and
hardwire zone input
connections.
ITI Part No. 60-774
RED BUS
STATUS LED
GREEN POWER
LED
SUPERBUS 2000
DEVICE ID
NUMBER LABEL
WIRING
TERMINALS
9712G01A.DSF
1

Advertisement

Table of Contents
loading

Summary of Contents for ITI 60-774 - Security SuperBus 2000 8-Zone Input Module

  • Page 1: Product Summary

    ITI Part No. 60-774 8557109A.DS4 Document Number: 466-1606 Rev. B November 2000 ˜ÃÌ>>̈œ˜Ê˜ÃÌÀÕV̈œ˜Ã Product Summary Module Components ® Each SuperBus 2000 8-Zone Input Module adds eight supervised hardwire zones. Each module includes mounting UNIT NUMBER hardware and eight 2.0K ohm end-of-line (EOL) resistors. DIP SWITCHES Power for the module is provided by the panel.
  • Page 2: Mounting The Module

    Installation Guidelines Installation Guidelines Installation For the maximum number of bus devices and touch- The module can be mounted pads per panel see Table 2. On a wall. Table 2. Maximum Bus Devices Per Panel Inside an Advent cabinet. Inside a Concord cabinet. Panel Maximum Bus Devices...
  • Page 3 Installation To Mount the Module in a Concord Cabinet MOUNTING HOLES Remove AC panel power and disconnect the backup battery. Remove and discard the module cover (Figure 2). Insert a support standoff shown in Figure 5 (supplied with panel) into the panel circuit board. SUPPORT STANDOFF PANEL MODULE...
  • Page 4: Wiring The Module

    Wiring the Module Wiring the Module To Wire Detectors to the Module Follow the maximum zone input wire length (run) To Wire the Module to a Panel guidelines in Table 5 based on the type of wire used. “«œÀÌ>˜Ìt “«œÀÌ>˜Ìt For Advent UL-864 Listed Installations, all inputs must On Advent panels, the BUS 1 and BUS 2 headers be dedicated to either fire or burglary applications.
  • Page 5 Installing a Cover Tamper Switch Installing a Cover Tamper Switch Setting the Module Unit Numbers If you are mounting the module in its own plastic and not On Concord (software versions 1.0–1.6) and mounting it inside a cabinet, you need to add cover tamper UltraGard Panels detection.
  • Page 6 Power Up and Bus Communication Power Up and On UltraGard Panels Bus Communication Verify that all wiring between the panel and module is correct. On Concord and Advent Panels Verify nonconflicting bus device unit number settings. Connect the panel backup battery and restore panel AC This section describes how to power up the panel and mod- power.
  • Page 7: Programming And Testing

    Programming and Testing Programming and Testing Specifications Refer to the specific panel Installation Instructions for add- Compatibility: Advent, Concord, UltraGard ing (learning) hardwire sensors into panel memory and test- ing sensors. Power Requirements: 12 VDC nominal, 35 mA maximum (from panel) If the UltraGard or Concord system uses hardwire sensors only, turn off the Receiver Failure feature in the panel.
  • Page 8 Notices Notices FCC Part 15 Information to the User Changes or modifications not expressly approved by Interactive Technologies, Inc. can void the user’s authority to operate the equipment. FCC Part 15 Class A This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules.

This manual is also suitable for:

Superbus 2000 60-774