D o o r Ac t iv a ti o n D e v i c e s
CX-TR Transformer Series
INSTALLATION INSTRUCTIONS
THIS PACKAGE INCLUDES:
(1) Transformer
(1) Parts kits
1. GENERAL DESCRIPTION
Camden offers a range of 12VAC to 24VAC standard, plug-in
and panel (nipple) mount transformers to support any low
voltage system application.
2. SPECIFICATIONS
Voltage
120V AC 60HZ
Dimensions
CX-TRN-2024:
2''H x 2-3/8'' W x 2-1/4''D
(50mm X 59mm x 56mm)
CX-TRX-2012:
2''H x 2-3/8'' W x 2-1/4''D
(50mm x 59mm x 56mm)
CX-TRX-2024
2-1/8''H x 2-3/8''W x 2''D
(54mm x 59mm x 50mm)
2''H x 2-3/8'' W x 2-1/4''D
(50mm x 59mm x 64mm)
CX-TRP-4016
3-3/4''H x 2-5/8'' W x 2-1/4''D
(94mm x 67mm x 57mm)
CX-TRX-4024
3. WIRING INSTRUCTIONS:
1. Determine the size and type of transformer needed, from
the chart above.
2. Connect the fuse holder to one of the leads of the
transformer secondary insert fuse. (For CX-TRX-2024 only).
3. Connect the secondary leads to the load (i.e. – motion
detector, control panel or another device.
4. Once all the secondary wiring is complete, connect the
primary leads to the 115 VAC, 60 Hz. 5. Ensure transformer is
securely fastened.
4. PRECAUTIONS:
1. Primary power must always be fused or protected by a
circuit breaker.
2. Never palace the transformer next to combustible
materials.
3. DO NOT short secondary leads together or allow them to
short to ground.
Page 1 of 4