This sensor is an active motion detector that emits high-frequency electro-
magnetic waves (5.8GHz) and receives their echo. It can detect the change in
echo caused by even the slightest movement in its detection zone. A
microprocessor then triggers the "switch light ON" command.
The sensor offers detection through various objects like doors, panes of glass or
thin walls. Additionally, a person or object moving towards the sensor is detected
more efficiently.
NOTE: The high-frequency output of this sensor is <10Mw - that is just one-
100th of the transmission power of a mobile phone or the output of a
microwave oven.
1. Take off the top cover by turning it anti-clockwise (see fig.1), and then fix the middle cover using two screws
(see fig.2).
2. Hold the base against the wall and mark where holes need to be drilled, paying attention to any existing wiring
in the wall.
3. Drill the holes and insert the wall plugs (6mm dia).
4. Put the power wire and load wire through the base holes.
5. Screw the base into place (see fig.3).
6. Connect the main power supply and the load wire to the connection terminal according to connection-wire
mark.
7. Close the middle cover (see fig.3) and adjust the knob.
Fit the glass shade and turn it clockwise (see fig.3).
8.
User Manual for Microwave Occupancy
INSTALLATION PROCEDURES
1
Sensor Series OCC58GRS08
Part numbers OCC58GRS08-1/ OCC58GRS08-2

Advertisement

loading

Summary of Contents for Infinite L-com OCC58GRS08 Series

  • Page 1 User Manual for Microwave Occupancy Sensor Series OCC58GRS08 Part numbers OCC58GRS08-1/ OCC58GRS08-2 This sensor is an active motion detector that emits high-frequency electro- magnetic waves (5.8GHz) and receives their echo. It can detect the change in echo caused by even the slightest movement in its detection zone. A microprocessor then triggers the “switch light ON”...
  • Page 2 TECHNICAL SPECIFICATIONS Power Supply 110-130 VAC (-1) / 220V-240 VAC (-2) Hold Time 10sec / 1min / 5min / 10min/ 15min / 20min / 25min / 30min Detect distance (radii.) 2m / 5m / 8m/ 10m Daylight sensor 10lux / 20lux / 50lux / 100lux / 200lux/ 300lux/ 500lux / 2000lux Detection Angle 360°...
  • Page 3 Light-control setting The chosen light response threshold can be infinite from approx. 2-2000lux. Turn it fully anti- clockwise to select dusk-to-dawn operation at about 2 lux. Turn it fully clockwise to select daylight operation at about 2000lux. The knob must be turned fully clockwise when adjusting the detection zone and performing the walk test in daylight.

This manual is also suitable for:

L-com occ58grs08-1L-com occ58grs08-2