Download Print this page
jablotron JA-122PB Manual
jablotron JA-122PB Manual

jablotron JA-122PB Manual

Bus combined pir motion and glass break detector

Advertisement

Quick Links

JA-122PB, JA-122PB-GR, JA-122PB-AN
Bus combined PIR motion and glass break detector
TYPE: 1PIRGBS2201OQ
The detector is a component of the JABLOTRON system. It serves for
the detection of human movement in building interiors and for the
detection of breaking glass windows. This detector combines two sensors
(the detector occupies two positions in the system) in one housing.
The detector is enrolled to two consecutive positions in the system.
The detector uses a PIR sensor for human movement detection.
Breaking glass is detected by a GBS sensor, which analyses air pressure
changes and sounds to detect the breaking of a glass window.
The detector should be installed by a trained technician with a valid
certificate issued by an authorized distributor.
Installation
It is necessary to take into consideration that there should be no
obstacles in the detector's field of view which quickly change temperature
(electric heaters, gas appliances, etc.), which move (curtains hanging
above a radiator, robotic vacuum cleaners, etc.) or the movement of pets.
Despite the detector being very immune to false alarms, it is not
recommended to install the detector opposite windows or floodlights or in
places with intense air circulation (close to ventilators, air conditioning,
vents, unsealed doors, etc.). There should be no obstacles in front of the
detector which might obstruct its view of the protected area.
Warning: the most common cause of unwanted detector activation is
improper placement. The section where the detector is a part of should
not be armed when people or animals are in the area.
Figure 1: 1 (8) – GBS sensor; 2 – LED indicator; 3 – PIR sensor lens;
4 – hole for locking screw 5 – cover tab;
1.
Open the detector cover of the detector by pressing the cover tab (5).
Do not touch the PIR sensor inside (13) as it can damage it.
2.
Loosen the right retaining screw (9) and release the electronics by
using the at the bottom of the plastic (14).
3.
The recommended mounting height for the detector is 2.5 m above
the floor level.
4.
Thread the bus cable and screw the rear plastic (vertically, with the
tab of the cover facing downwards).
5.
Reinstall the electronics, secure with the tab (14), followed by the
screw (9) and connect the bus cable to the terminals (7).
Always connect the bus cable with the system
power completely off.
6.
Follow the installation manual of the control panel. The basic
procedure is as follows:
a.
After powering on the control panel, the yellow LED (10) blinking
indicates that the detector is not assigned to the system.
b.
In the F-Link software, select the desired position in the Devices
tab and enable the enrolling mode by clicking the Enroll button.
c.
Use the option to select a detector from the list JA-122PB and
double-click to confirm learning - the yellow light (10) goes off.
7.
Close the detector cover. To ensure proper compliance with the
standards, the top must be secured with the locking screw (4).
Notes:
The detector can also be enrolled into the system by pressing the cover
tamper sensor (12).
The detector can be enrolled by entering the production code (11) in the
F-Link software (or a bar code reader). Enter all digits located below the
bar code (1400-00-0000-0001).
If you want to remove the detector from the system, erase it from its
position in the control panel. In case that only the GBS part (B) is
removed, the PIR remains functional.
In order to increase white light immunity, it is possible to utilize a grey PIR
lens JS-LT82601B.
JA-122PB, JA-122PB-GR, JA-122PB-AN
After replacing the lens, check that the detector covers the area correctly
(an incorrectly installed lens can cause the detection to malfunction).
Figure 2: 6 – connector for external tamper contact of the JA-191PL joint bracket;
7 – BUS terminals; 8 (1) – GBS sensor; 9 – GBS module locking screw;
10 – LED status indicators; 11 – production code; 12 – cover tamper sensor;
13 – PIR sensor; 14 – PCB tab
Internal settings of the moduleOpen the F-Link software, go to the
Devices tab. Click on the Internal settings option at the detector's
position to open a dialogue window where you can set the following
options: (* indicates default settings).
LED indication: Disables/Enables* movement indication with a red LED
(10).
PIR immunity level: Defines false alarm immunity. The Standard* level
combines basic immunity with a rapid reaction. The Increased level provides
higher immunity, but the detector reaction is slower.
GBS break detection sensitivity (%): The sensitivity of GBS can be
adjusted with the slider (75%*).
Sensor of tearing-off from the wall: Disables*/Enables monitoring of an
additional tamper contact of the JA-191PL jointed bracket.
Detection characteristics
The PIR detector is factory fitted with a 90°/12 m lens. Area coverage
– see following picture.
Figure: Detection characteristics of the PIR sensor
1 / 2
MOQ51603

Advertisement

loading

Summary of Contents for jablotron JA-122PB

  • Page 1 In the F-Link software, select the desired position in the Devices tab and enable the enrolling mode by clicking the Enroll button. Use the option to select a detector from the list JA-122PB and double-click to confirm learning - the yellow light (10) goes off.
  • Page 2 Figure: Detection characteristics of GBS sensor. Certification body Trezor Test s.r.o. (no. 3025) Detector with a white lens (JA-122PB) offers standard protection In compliance with EN 50130-4, EN 55032, EN IEC 63000, against white light as required by regulation (up to 6000 Lux). Detector...

This manual is also suitable for:

Ja-122pb-grJa-122pb-an