Download Print this page
Redback A 4491 Operating Manual

Redback A 4491 Operating Manual

Input source selection remote plate

Advertisement

Quick Links

www.altronics.com.au
Operating Manual
A 4491/92
Input Source Selection Remote Plate
A 4491
A 4492
Overview
The A 4491and A 4492 wall plates allow remote selection of the zone's input audio source and volume level.
In addition, when connected to the A 4478 or A 4479 local zone input wallplate, it allows the use of a local signal source,
such as a wired mic, radio mic or aux source, which VOX mutes the selected input from the A 4480.
The LCD displays the zone name, the input sources and zone and local input volume levels.
Note: The volume controls only adjust the volume of the 8 aux input sources, plus the local input (when used).
General and emergency paging from the A 4480 Audio Switcher will override these volume settings.
Features
• Remote selection of input audio source
• Volume control of zone input
• Volume control of local input
• Mute function
• Personal Identification Number 2 stage Lockout Function
• Zone Lockout
• DIP switch selectable Menu Lockout Function
• Provision for input of local microphone or line level audio via A 4478 or A 4479 wall plate
• Cat5e connection to A 4480
• Powered from the A 4480
Menu Accessed Features
• Enable/Disable Local Input
• Vox Sensitivity Level Adjustment
• Vox Delay Adjustment
• Disable Input Sources
• Backlight Timeout Adjustment
• Change Pin Number
• Change Zone (Wall plate ID)
• Lock/Unlock Screen
Redback® Proudly Made In Australia
User manual revision number: 1.2 07/10/2015

Advertisement

loading

Summary of Contents for Redback A 4491

  • Page 1 • Vox Sensitivity Level Adjustment • Vox Delay Adjustment • Disable Input Sources • Backlight Timeout Adjustment • Change Pin Number • Change Zone (Wall plate ID) • Lock/Unlock Screen Redback® Proudly Made In Australia User manual revision number: 1.2 07/10/2015...
  • Page 2 Connecting A 4491/92 remote plates to the A 4480 Audio Switcher A maximum of eight A 4491/92 remote plates can be connected back to the A 4480 Audio Matrix, with a maximum of one wall plate per zone as shown in Fig 1.
  • Page 3 Screen Layout Guide Zone Label This is the label set by the A 4480 used to identify the Fig 4 shows the layout of the A 4491/92 LCD. zone (e.g. Office). Local Input Button Press this button to activate the local input. The button will change to red when active.
  • Page 4 Setting the time to zero keeps the backlight on continually. Set the time to 1 sec and the backlight will turn off after 1 sec etc. Fig 5. A 4491/92 Menu Screen 5) Lock/Unlock Screen There are two levels of user lockout available.

This manual is also suitable for:

A 4492