Download Print this page

Oliveri Oslo OS127BTW Installation Instructions

Advertisement

Quick Links

VITREOUS CHINA
Wall Faced Toilet Suite
Installation instructions for Wall Faced Toilet Suite
THIS TOILET MUST BE INSTALLED BY A LICENSED PLUMBER IN
ACCORDANCE WITH LOCAL REGULATIONS
This Oliveri toilet suite is manufactured to Australian standard AS 1172.1 & AS 1172.2
Remove all products from packaging:
Check the product for damage, if the product is damaged return to store of purchase.
Check the product is complete with all components required to install.
This product is to only be installed by a licensed plumber, failing to do so will void warranty.
This product is to be installed as per Australian Standard and local authority requirements.
WARNING: DO NOT BED THE PAN IN PLACE USING CEMENT, CONCRETE OR SIMILAR
MATERIAL, DOING SO WILL VOID THE PRODUCT WARRANTY.
N.B Refer to Geberit Sigma 8 in-wall cistern installation
instruction sheets when using this installation
document to ensure the Wall Faced toilet suite is
installed correctly.
Cistern Installation:
Refer Geberit Sigma 8 installation instruction sheet in conjunction with the dimensional pan
drawings on this document for correct installation.
1.Mark the centre line of the Pan connector on the floor for "S" trap installation or on the wall
for "P" trap installation.
2.Place the pan into position centralising the pan on your centre line, draw around the pan
base and mark the entry points on the floor to where the floor fixing holes are on the side
of the pan.
3.Remove the pan and drill and screw into place the floor fixing brackets, set the floor fixing
brackets 15mm inside the line drawn around the base of the pan. Use suitable floor fixing
screws and toggles to suit the floor material.
4.
Critical:
The pan must be on a level surface square to the wall, if the floor slopes away
the pan will need to be levelled using suitable floor chocks around the pan to support and
stabilise the pan.
5.The standard variance bend (ZH6200) supplied has a set out of 55mm to 110mm, the
optional Variance bend (VT103) has a set out of 150mm to 180mm and is purchased as
optional extra.
2021-06/Version 1.1
Oslo
Product code:OS127BTW
VI1273ST
"S" trap installation
6.Place the variance bend into the floor outlet, from the finished floor to the centre of the pan
outlet is 125 mm, ensure the variance bend is straight and square to the wall and centrali-
sed to the pan outlet height, assemble the variance bend wall brace and fix to the finished
wall. Measure the distance from the back edge of the pan to the "P" trap edge and add on
sufficient length for the Variance bend collar to fully engage the "P" trap.
Remove the locking ring and rubber boot from the Variance bend. The distance between
each ridge on the Variance bend is 10mm. Once the excess has been cut off the variance
bend reassemble the rubber boot and locking ring.
7.Slide the pan into place being careful that full engagement of the pan variance bend and
cistern flush pipe has been achieved.
N.B
pre-soaping the rubber boot on the Variance bend and key seal on the flush pipe will
assist with easier engagement.
8.Once the pan is in place and connected to the Variance bend and Flush pipe screw the
pan in place using the supplied fixing screws and cover.
9. Assemble the seat using the seat assembly instructions supplied in the seat box.
DO NOT OVER TIGHTEN SCREWS AS THIS MAY CAUSE THE PAN TO CRACK
DO NOT USE OFFSET PAN COLLARS ON S OR P TRAP INSTALLATIONS AS
THIS WILL COMPROMISE WASTE DISCHARGE. DOING SO WILL VOID THE
PRODUCT WARRANTY.
OS127BTW & VI1273ST Installation Instructions

Advertisement

loading

Summary of Contents for Oliveri Oslo OS127BTW

  • Page 1 Installation instructions for Wall Faced Toilet Suite THIS TOILET MUST BE INSTALLED BY A LICENSED PLUMBER IN ACCORDANCE WITH LOCAL REGULATIONS Product code:OS127BTW This Oliveri toilet suite is manufactured to Australian standard AS 1172.1 & AS 1172.2 VI1273ST "S" trap installation Remove all products from packaging: 6.Place the variance bend into the floor outlet, from the finished floor to the centre of the pan...
  • Page 2 In the event this product is rendered obsolete and a replacement product is required. 303 ±5 125± 5 Oliveri Solutions Pty Ltd reserves the right to supply a product of equal substitution at their discretion. Standard Pan Connector 50-75 Pan Set Out: 50-75 Our goods come with guarantees that cannot be excluded under the Australian Consumer Law.

This manual is also suitable for:

Oslo vi1273st