PRODUCT DESCRIPTIONS:
These instructions cover the following FloTech products:
FT151RL 2 Wire Optic ROM LINK Replacement Sensor
FT152RL 2 Wire Optic ROM LINK Replacement Retain Sensor
10688 Gender Adapter
PRODUCT DESCRIPTION:
The FT151RL, FT151RL-12 and FT152RL are replacement sensors for the Civacon ROM
link and compatible with 1554-007, -012, -018 Civacon overfill sensors and 1000RL
Civacon retain sensors. These instructions provide a picture overview of additional steps to
properly install the FT151RL series and FT152RL sensors into a ROM LINK harness.
Installation Steps:
Refer to GENDER ADAPTER picture, page 3
1) Remove the Civacon sensor and housing. You will not use any of the original
Civacon sensor components. Leave the Civacon harness in place if in good
condition.
2) Remove sensor cap and probe from housing. Insert Cable gland into the sensor
housing. Use some pipe sealant to insure a water-tight connection.
3) Cut FT151P sensor to length so that sensor length is set to 60 gallons or 3% of tank
capacity compartment.
10688PA Rev: D Jun 2021
Instruction Manual 10688PA
FloTech Replacement Sensor for
ROM LINK 2 Wire sensors
Page 1 of 4

Advertisement

loading

Summary of Contents for FloTech FT151RL

  • Page 1 1554-007, -012, -018 Civacon overfill sensors and 1000RL Civacon retain sensors. These instructions provide a picture overview of additional steps to properly install the FT151RL series and FT152RL sensors into a ROM LINK harness. Installation Steps: Refer to GENDER ADAPTER picture, page 3 1) Remove the Civacon sensor and housing.
  • Page 2 6) Mount the sensor housing into the manhole cover. 7) Connect the FloTech Gender Adapter to the Civacon harness pig tail for the compartment this sensor is replacing. Use a little dielectric grease or Vaseline in the connector to help repel moisture.
  • Page 3 9) Next use the provided tie wraps to fasten the pigtail to the main harness as shown in the photo below. These cable ties will ensure the connection is not accidentally pulled apart or damaged. ROM LINK Gender Adapter (Retain and Overfill) 10688PA Rev: D Jun 2021 Page 3 of 4...
  • Page 4 10) Check all connections. Power up the monitor to check out operation. 11) IMPORTANT NOTICE: Perform a WET TEST on each sensor and look for the corresponding RED sensor LED to light and the permit LED to go out. REMEMBER, to get a Green permissive light, For sales information contact Dixon Bayco In the United States: In Canada:...

This manual is also suitable for:

Ft151rl-12Ft152rl