Download Print this page

MAINLINE FloodStop OnSite PRO FS3/4NPT Installation And Operating Manual

Leak detection & automatic water shut-off system water heater kit

Advertisement

Quick Links

by
PRO"
FloodStop
OnSite
Leak Detection & Automatic
Water Shut-off System
Water Heater Kit - FS3/4NPT FS1 /2NPT
FS1/4C FS3/8C FS1NPT FS1.25NPT
c@us
LISTED
Flood Stop Water Heater Kit
by
FloodStop
On Site PRO�
Congratulations on your purchase of a FloodStop by OnSite PRO�
electronic water leak detection and automatic water shut-off kit for
water heaters. This product has been designed to give you years of
reliable service and minimize home water damage by detecting water leaks and
automatically shutting off the water supply.
To ensure proper installation and to maximize the performance of your
FloodStop water leak detection system, please read this manual
thoroughly.
PLEASE READ CAREFULLY BEFORE PROCEEDING:
If a leak is detected, the Flood Stop Valve will shut off the water going to the
water heater. This will stop the continuous flow of water from the water supply
to the water heater. However, all or some of the water that is already in the water
heater may still leak out onto the floor.
NOTE: This unit was shipped with an installation and operating manual that
contains important information about its operation. If you are
installing this unit for use by others, we recommend you leave this manual - or a
copy of it - with the user.
Water Heater Kit- Model FS3/4NPT
FEATURES:
Control Panel has easy to read, lighted function buttons
AC Power with battery backup - For continued operation in the
event
of power outages
Solid brass, full port motorized ball valve for dependable, long
lasting performance
Valve automatically shuts off the water supply when a leak is detected
Automatic monthly maintenance cycling of the valve to ensure reliable operation
Valve can be opened and closed with the touch of a button
Activates an audible alarm when a leak is detected
Mute button to silence the audible alarm
Can be reset and reused continuously with the touch of a button
9. Plug the pin on the end of the AC Adaptor cord into the
9.
bottom of the Control Panel, and then plug AC Adaptor
into a wall outlet. Green Indicator lights will start to
flash, showing you have power. Note that a red low
battery indicator light will also flash about every 30
seconds, and the unit will beep once a minute until the
batteries are installed.
NOTE: If a nearby wall outlet is not available you will need to
purchase a thin low voltage FloodStop"AC Adaptor
Extension Wire" Model# WAE-09 (available where you
purchased your FloodStop System). This wire extends the
length of the AC Adaptor cord.
CAUTION: Do not plug the AC Adaptor Into an
extension cord.
10.
10. Flood Stop has a battery backup system that allows
the unit to continue working in the event that you
have a power outage. To set up the backup system,
open the front of the Control Panel and install 4 fresh
AA alkaline batteries (batteries not included). The low
battery indicator light will now stop flashing and the
beep will stop.
CAUTION: Replace batteries once a year or sooner as
necessary. If batteries need to be changed sooner, a red low
battery indicator light will flash and a beep will sound.
Installation
11. Shut off the previously opened faucet and turn on
both valves that were shut off in steps 1 and 3.
Check for leaks. Note that a green status light on the
Control Panel will indicate whether the Flood Stop
Valve is open or closed.
How to Operate your Control Panel
1. Top button opens Flood Stop Valve
2. Middle button closes FloodStop Valve
3. Bottom button mutes the audible alarm that
sounds when a leak is detected
Testing Your FloodStop System
1. Push the Open button to make sure Flood Stop Valve is open.
• When the FloodStopValve is opening or closing, you will hear the valve motor operating for a
few seconds.
2. Saturate a rag with water and squeeze over Leak Sensor, or dip the Leak Sensor into a small bucket of
water. Once the Leak Sensor is wet, it will signal the Flood Stop Valve to close, then an audible alarm will
sound and a red light will flash.
• Push the Mute button to srlence the alarm, and note that
the red light will continue to flash. This means
the Flood Stop Valve is closed, and will remain closed until you push the Open button.
• Before the Flood Stop Valve can be opened, the Leak Sensor needs to be dry. There is no need to
unplug the AC Adaptor when drying off the Leak Sensor.
• The water test can be done with the paper sleeve still on
the Leak Sensor. Note that the paper sleeve is
reusable, but once it gets wet you will need to let it air dry flat before placing it back on the Leak Sensor.
Can be tested at any time with the touch of a button
Can accommodate additional water leak sensors
Installation and
1 Year Limited Warranty
Operating
This Package Contains:
Manual
A
(1) FloodStop Motorized Brass
x
Valve (3/4" FIP
B
(1) Control Panel
C
(1) Leak Sensor with Paper Sleeve
D
(l)ACAdaptor
E
(l)WireHarness
F
(1) Hook& Loop Mounting Pad
G
(2) Mounting Screws with Anchors
e
Check to make sure everything in the package matches the Contents Listing above.
Read the instructions thoroughly before installing or operating the FloodStop system.
Warning: Do not put finger(s) inside Flood Stop Valve. Risk of serious injury may occur.
Caution: Do not grip plastic motor drive for leverage when tightening Flood Stop Valve.
Q 2012 OnSite PRO Inc.
Preparation
CAUTION: Make sure the Flood Stop Valve is not connected to the adaptor fitting(s) when soldering.
WARNING:
- For use with water only.
- Do not install on gas line.
STOP:You may need to purchase additional fittings to install the FloodStop Valve. If you
are not sure how to install the FloodStop Valve to your existing water line, we recom­
mend that you contact a licensed Plumber.
Installation
1. Shut off main water supply valve.
Step 4 instructs you to install the FloodStop Valve
(3/4" FIP x 3/4" MIP) between the rigid water line
coming off the manual cold water valve and the wa­
ter heater. Most rigid lines will be copper. Evaluate
your line and determine which size adapter fitting
you will need (the most common one will be 3/4.
solder x 3/4• MIP). Then determine what size union
you will need between the Flood Stop Valve and the
water heater. Note that in some cases you can use
a flexible or corrugated water heater connector in
place of a union.
2. Open faucet nearest water heater to relieve
water pressure.
3. Shut off the manual cold water valve that supplies
water to the wau�r heater. Note that the top of the
water heater will usually be marked "Cold" or"lnlet"
at the point where the cold water line is connected.
Pressure Drop Data:
The maximum pressure drop for this device
is 2 psi at a flow rate of 5.5 gpm for NPS-3/4
and larger.
Helpful Hints
If the Leak Sensor Paper Sleeve is misplaced or becomes unusable, a paper towel can be used
in its place.
The Leak Sensor has two sets of prongs so you can connect additional Leak Sensors. This is
helpful when you have the Leak Sensor placed Inside a water heater pan, but also want one
outside the pan to sense other leaks such as a pressure relief valve failure. You can also link
them together so they are positioned at different locations around your water heater.
Once a month, the FloodStop Valve will automatically close and open by itself. The Control
Panel is programmed to run this cycle to ensure that the valve continues to function properly
in the event that it needs to shut off the water.
Hanging Wires may be tied together using twist ties (Not provided).
-
Troubleshooting
0
Problem
Status light does not light
; �
-
,..
-
I
[)
I
);
No water comes out of hot side of faucet
No water comes out of hot or cold side of faucet
FloodStop Valve does not operate
Problem
FloodStop Valve does not operate (continued)
Leak Sensor becomes wet but Flood Stop Valve
does not close
3/4" MIP)
-.
I . . -
• 0 .
Ci)
1.
3.
What to Check
- Make sure there is power to the outlet.
- Unplug AC Adaptor cord from Control Panel
and plug back in.
- If an AC Adaptor extension wire was used,
unplug both ends and reconnect
- Make sure fresh batteries are in the Control
Panel.
- Push Open button to make sure LeakSmart
Valve is open.
- Make sure the manual cold water valve is
open.
- Make sure a manual hot water valve was not
accidentally closed.
- Make sure main water shut-off valve is
open.
- Make sure both sides of Sensor are dry.
- Make sure there is power to the outlet.
- Unplug AC Adaptor cord from Control Panel
and plug back in.
What to Check
- Unplug 6-pin connector from Control Panel
and plug back in.
- Locate plug connection between Control
Panel and FloodStop Valve. Unplug the
connection and reconnect, making sure
arrows on side of plugs line up.
- If an AC Adaptor extension wire was used,
unplug both ends and reconnect.
- Make sure fresh batteries are in the Control
Panel.
- Unplug long Hat wire from Leak Sensor
and reconnect.
- Make sure there is power to the outlet.
- Unplug AC Adaptor cord from Control Panel
and plug back in.
- Unplug 6-pin connector from Control
Panel and reconnect.
4.
4. Position the Flood Stop Valve so that the arrow on the
side of the valve is pointing to the water heater. Install
the FloodStop Valve between the rigid water line
coming from the manual cold water valve and the
water heater.
NOTE: The Flood Stop Valve should be installed within 2
feet of the water heater so that the Leak Sensor can lay
flat on the floor.
5. Mount the Flood Stop Control Panel in an easily
5.
accessible location within 30 inches of the LeakSmart
Valve. You may mount the panel using the screws and
anchors or Hook & Loop Mounting Pad provided. When
using the Hook & Loop Mounting Pad, make sure the
adhesive is put on a clean, dry surface.
NOTE: Depending on the location you pick, and the distance
between the Control Panel and the FloodStop Valve, you
may need to purchase a leakSmart Control Panel to Valve
Extension Wire, Model# CEXT-09 (available where you
purchased your Flood Stop System).
6. With the contacts of the wire harness connector facing
6.
you, plug the 6-pin connector end of the Wire Harness
into the bottom of the Control Panel.
7.
7. Take the short round wire coming from the Control
Panel and plug it into the wire coming from the
FloodStop Valve. Make sure the arrow on the
side of each plug lines up with each other.
NOTE: The Leak Sensor comes with a paper sleeve. If the
Leak Sensor is going to be placed in a metal water heater
pan, make sure you leave the paper sleeve on. If the Leak
Sensor makes contact with metal, it will signal the
Flood Stop Valve to shut off. The paper sleeve acts as a
barrier between the Leak Sensor and the metal. When the
paper sleeve becomes wet, It will signal the Flood Stop Valve
to shut off. If the Leak Sensor will not be contacting metal,
you may remove the paper sleeve.
8. Connect plug on end of long flat wire coming from
8.
Control Panel to either set of prongs on the Leak
Sensor, pushing until plug snaps in place. Then place
Leak Sensor on the floor next to the water heater,
preferably on the side that is in line with the floor drain.
NOTE: Additional Leak Sensors can be connected together
for added protection. For additional Leak Sensors, pur­
chase FloodStop Water Leak Sensor, Model# XS-01 (avail­
able where you purchased your Flood Stop System).
CAUTION: Do not place Leak Sensor or cord in a walk way
or other location that may cause someone to trip and fall.
Controller Mounting Template
$
27
(ex 3-�4)
87mm
Notice
• Not to be used on Fire Protection Systems
• Four AA batteries must be used as backup
or system will beep continually.
Problem
What to Check
Leak Sensor becomes wet but FloodStop Valve
- Locate plug connection between Control
does not close (continued)
Panel and Flood Stop Valve. Unplug the
connection and reconnect, making sure
arrows on the side of plugs line up.
- If an AC Adaptor extension wire was used,
unplug both ends and reconnect.
- Make sure fresh batteries are in the Control
Panel.
Flood Stop Valve closed but now will not open
- Make sure both sides of Leak Sensor are
dry.
The alarm goes off for no apparent reason
- Leak Sensor is touching metal, or the
concrete is sweating causing high humidity.
Correct the problem by placing the Paper
Sleeve on the Leak Sensor, or use a paper
towel as a barrier.
Manual Operation of Flood Stop Valve
1. Unplug the connection between the Control Panel and the Flood Stop Valve.
2. Pull the plastic motor cover off the Flood Stop Valve and slide it down the wire until it stops at the
plug. Note that no tools are needed to remove the cover.
3. Use a mark1H and draw a line across the top of the plastic motor housing. This way once the motor
is removed you will know how to reposition It for assembly.
4. Remove the 4 screws using a Phillips head screwdriver.
5. Place thumb and finger on plastic gear and rotate clockwise to open valve or counter clockwise to
close it.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy, and if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encour­
aged to try to correct the interference by one or more of the following measures:
• Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Flood Stop Water Heater Kit
1 Year Limited Warranty
OnSite PRO Inc. warrants the enclosed Flood Stop product to be free from defects in materials or
workmanship, under normal use and service, for a period of one (1) year from the date of purchase.
If at any time during the warranty period the product is determined to be defective, OnSite PRO Inc.
shall repair or replace it (at our option). The warranty is limited to defective parts as stated. All costs
of removal and installation of the Flood Stop product, including the replacement of warranty parts, are
the responsibility of the purchaser. The manufacturer shall not be liable for incidental, consequential,
or
or special damages arising at, or in connection with product use
performance, except as may
otherwise be accorded by law. Some states do not allow the exclusion limitation of incidental or con­
sequential damages, so the limitation may not apply to you. Any damage to this FloodStop product as
a result of misuse, abuse, neglect, accident, improper installation, or any use violating the instruction
manual furnished by us will void this warranty. This warranty does not cover damages or loss caused
by defects, and the owner's use of the Flood Stop product confirms the understanding that this prod­
uct does not constitute an insurance policy, and is only a loss mitigation product used to reduce the
risk of water damage.
To obtain warranty service, call our Customer Service Department at 1-800-667-4833, or e-mail us at
sales@getfloodstop.com. You may also send the product and original dated receipt, prepaid US post­
age to: On Site PRO Inc 28222 Shadowland Circle, Modjeska Canyon, CA 92676, Attention: Customer
Service.
0,
C>
$
-

Advertisement

loading

Summary of Contents for MAINLINE FloodStop OnSite PRO FS3/4NPT

  • Page 1 PRO" FloodStop OnSite Can be tested at any time with the touch of a button • 4. Position the Flood Stop Valve so that the arrow on the Can accommodate additional water leak sensors side of the valve is pointing to the water heater. Install Leak Detection &...
  • Page 2 WARRANTY INFORMATION Mainline products will be covered by IPS Corporation’s limited warranty. It is as follows: IPS Corporation (“IPS Corp.”) warrants to all original purchasers of IPS Corp. products that all new IPS Corp. products shall be of good quality and free from defects in material and workmanship for the product’s shelf life. If any IPS Corp. product becomes defective or fails to conform to this written limited warranty under normal use and storage conditions, and if the original purchaser complies with the terms of this limited warranty, then IPS Corp.
  • Page 3 TEST-TITE. IPS Corporation warrants each pneumatic test plug to be free from defects in materials and workmanship for a period of THREE (3) Years from the date of manufacture, under normal use and service. This warranty does not apply to any goods which have been subjected to misuse, mishandling, misapplication, neglect or repair other than by the manufacturer.

This manual is also suitable for:

Floodstop onsite pro fs1/2nptFloodstop onsite pro fs1/4cFloodstop onsite pro fs3/8cFloodstop onsite pro fs1nptFloodstop onsite pro fs1.25npt