INSTALLATION INSTRUCTIONS
464, 424 & 324 POST-MIX VALVES
The Flomatic valves are available in manual, electric,
portion control and automatic fill models. All Flomatic
valves share the same mounting and flow control char-
acteristics. The 324 valves are also compatible with
the 300-Q mounting block. Those instructions are not
included here.
MOUNTING BLOCK
Prior to installation determine which mounting block
you need. The Flomatic mounting block kit 5007842
has inlet "O" rings sized for both inlet port sizes
(located at the rear of the block) port. Sized at 0.380
inches is compatible with most current mounting block
inlet fittings.
INSTALLATION / REPLACEMENT
Be sure to relieve system pressure prior to beginning
work. When replacing most other brand valves with
the Flomatic valve, remove the existing mounting
block and install the appropriate Flomatic mounting
block. This is an easy first step – just align the four bolt
holes and mount. The Flomatic mounting blocks have
a positive shut off and mounting system to prevent
accidental removal while the system is pressurized.
The valve cannot be removed unless the shut-off
valves are in the closed position (arrows pointed
across the service line).
The hole pattern for most current valves will have key
slots for the product supply lines. Some older valve
mountings may require the use of the "S" clip 2 to hold
the product supply lines in place (available as an
option).
Part Number 5027981 8/10

Advertisement

loading

Summary of Contents for Flomatic 464

  • Page 1 INSTALLATION INSTRUCTIONS 464, 424 & 324 POST-MIX VALVES The Flomatic valves are available in manual, electric, portion control and automatic fill models. All Flomatic valves share the same mounting and flow control char- acteristics. The 324 valves are also compatible with the 300-Q mounting block.
  • Page 2 FLOW CONTROL & BRIX Two simple adjustments are all you need to brix the Flomatic valves. You will need a Flomatic S tube syrup separator, 5/32 inch hex wrench, watch and brix cup. Place the S-tube syrup separator over the syrup dif- fuser and you are ready to begin.
  • Page 3 Simply set the syrup ratio and you are done. Flomatic juice valves may combine with a flow washer on the water side. The syrup side may be manufactured with a flow control or metering screw. The metering screw turns clockwise to close and counter clockwise to open.
  • Page 4 WATER / SODA ONLY Installation of a Flomatic Add-A-Lever is easy. If you have the pallet actuators as described above, simply remove the valve cover and place the Add-A-Lever (with the side attachment removed) on the end of the pivot pin.
  • Page 5 FILL handed operation: push and hold the program Hidden Switch 464 Portion Control switch with one finger Touch Pad while dispensing the cup size you wish to program with another. Once the drink is full, simply release the cup size button to end the pour cycle and then let go of the program switch.
  • Page 6 The portion control module will finish the pour whether a cup is there or not. AUTOMATIC FILL VALVE The Flomatic Automatic Fill valve can be used to dis- pense both carbonated and noncarbonated products. The valve is factory set for carbonated products where...
  • Page 7: Troubleshooting

    TROUBLE SHOOTING Occasionally, the valve will not perform as desired. Here are some helpful hints: BRIX: Reset the flow rate and re-brix the valve. Look for foreign matter in the adjustment screws, flow controls or pallet seats. Sometimes if a system is not flushed completely at startup, foreign particles, etc.