Quick Links

Triad RackAmp 700 DSP Quick Start Guide
RackAmp 700 has significant changes from previous Triad RackAmps. They are highlighted in bold italic.
You must select the Triad Subwoofer Model that the RackAmp 700 DSP will drive when the amp is initially
power on or after a factory reset. Once confirmed, the subwoofer model can only be changed in the Installer
Setup Menu.
Triad In-Wall and In-Ceiling subwoofer model names are labeled on their front baffles. The RackAmp 700 DSP
has EQ profiles for all current Triad Sub models (some require 8Ω enclosures). A new FLAT selection has no
model EQ and its Sub High Pass Filter is turned OFF. If you do not see your Triad subwoofer model contact
support for help.
Power On Methods — Options include Auto Sense (the default), Trigger (low voltage), IR/IP, and Manual (the
front panel button). Other IR commands continue to work if IR/IP is not used for powering the amp on.
For remote troubleshooting and configuration, use IR/IP to let the amp go to standby mode. See the "Triad
RackAmp 700 DSP v2 Instructions for IP Setup & Advanced Features" at snp1.co/tc for more info.
To disable all power on methods for the amp (except manual), press the front standby button. Press the
standby button again to resume normal functions.
A solid blue light indicates the amp is on. A red light means the amp is in standby. Flashing red means the amp
is in protection mode.
Protection — No output? If the front panel button is flashing red the amp is in protection mode. This could be
from a short, heat, or over voltage. Check the cables for shorts and verify the amp has adequate ventilation. If
the amp is hot, power it off and allow it to cool down (up to 30 minutes). If that doesn't work, reset the RackAmp
by switching off the Mains power switch, next to the back panel's power cord, for 30+ seconds.
Input Selection & Outputs — From the User Menu, select the desired input from default RCA (LFE unbalanced),
XLR (unbalanced), and Speaker. Only the selected input gets amplified. Speaker level inputs cannot pass
through to any output.
For daisy chaining, only the selected XLR or RCA input can pass through to its output. Both XLR and RCA
outputs can be high pass filtered and delayed for bass management and time alignment of 2-channel
systems or for multiple subs to produce different parts of the bass spectrum.
Menus — Menu changes affect all inputs and occur in real time. All changes are saved instantly. Volume
changes are not volatile. RCA (unbalanced), XLR (balanced), and Speaker inputs can be filtered. The default
user volume is 00dB. Switching the amp to Standby does not reset the volume to 00dB. For permanent gain
matching, use the User Volume. There is no Input Gain adjustment in the Installer Menu.
Presets — Use presets to change the sound to match your circumstance. The default preset is Normal. The
Cinema preset boots the bottom end at 40Hz for extra oomph during movies. The Night preset reduces deep
subwoofer frequencies at 35Hz as a courtesy to others. User 1, 2, and 3 Custom presets are only configurable
via IP to match specific circumstances using 2 parametric filters and a separate default volume per user preset.
The amplifier maintains its preset when put into standby. For repeatability, calibrate to the Normal preset.
RackAmp 700 DSP drives speaker loads of 4Ωs or higher. Use with 8Ω Mini and Bronze subs only, as singles or
in pairs.
Advance Features — To configure 6 Band Room EQ and custom User Presets, read the "Triad RackAmp 700
DSP v2 Instructions for IP Setup & Advanced Features" at snp1.co/tc for more info.
IR Input/Output — The IR input accepts commands from IR distribution. The output allows daisy chaining IR
control of multiple RackAmp 700s. Insert a 3.5mm (mono) plug into the IR input to disable the front panel IR
receiving eye.
Input Voltage & Fuses — The RackAmp 700 automatically adapts to 110VAC or 220VAC. The only necessary
change is an IEC power cord that''s appropriate for the local conditions. Fuse values do not change. There are
no internal fuses. The fuse is accessible is to the left of the IEC power cord socket.
Firmware Updates — Read "Firmware Update for Triad RackAmp 700" at snp1.co/tc for more info.
Specifications — 700 Watts; 3.5 Amps/220VAC, 7 Amps\110; 10AL250VP Fuse; 3ms latency.
Copyright ©2024, Snap One, LLC. All rights reserved.
Rev B 240129
A
Unpacking/Contents
RACKAMP 700 DSP
OFF
ON
presets
NORMAL
CINEMA
NIGHT
ON
PEQ
USER 1
USER 2
USER 3
OFF
MUTE
back
enter
volume
B
Rack installation
Install rack ears with the pre-packaged
screws. Keep ventilation slots clear for
airlflow, particularly right front top and
bottom.
Technical Support
For chat and telephone, visit snp1.co/techsupport • Email:
TechSupport@SnapOne.com. Visit snp1.co/tc for discussions,
instructional videos, news, and more.
Warranty and Legal Notices
Find details of the product's Limited Warranty at snapone.com/legal
or request a paper copy from Customer Service at 866.424.4489.
Find other legal resources, such as regulatory notices and patent
and safety information, at snapone.com/legal.
C
Connections
Output (to subwoofer), Inputs, AC cord
Preprocessor LFE or AV Receiver OUT
4Ω minimum
LFE
+
L
+
L
R
LFE
INPUT
INPUT
OUTPUT
4Ω minimum
+ -
+ -
+ - + -
L
OUTPUT
R
INPUT
OUTPUT
INPUT
OUTPUT
USB
ETHERNET
SPEAKER INPUT
LV TRIGGER
INFRARED
R
INPUT
OUTPUT
RED
BLACK
To single 4Ω Silver, Gold &
Daisy chain multiple amps by
Platinum subs and single
sending Unbalanced RCA or
or dual 8Ω Mini and
Balanced XLR source signal
Bronze subs only.
from Outputs to the next
amp's Inputs.
LFE
+
L
R
L
+ -
L
+ -
R
INPUT
INPUT
OUTPUT
4Ω minimum
+ -
+ -
+ - + -
OUTPUT
R
SPEAKER INPUT
INPUT
OUTPUT
INPUT
OUTPUT
USB
LV TRIGGER
ETHERNET
INFRARED
SPEAKER INPUT
New on the RackAmp 700 DSP is speaker level input
IR Input — Accepts feed from IR distribution using cables
with 3.5 mm plugs. Plugged Input disables front panel IR
eye. Daisy chain IR to multiple RackAmps from IR Output
to the next amp's IR Input.
INPUT
LFE
+
L
L
R
INPUT
INPUT
OUTPUT
4Ω minimum
+ -
+ -
+ - + -
OUTPUT
OUTPUT
R
INFRARED
SPEAKER INPUT
INPUT
OUTPUT
INPUT
OUTPUT
USB
LV TRIGGER
ETHERNET
INFRARED
LFE
+
L
L
R
INPUT
OUTPUT
INPUT
4Ω minimum
+ -
+ -
+ - + -
INPUT
OUTPUT
R
SPEAKER INPUT
INPUT
OUTPUT
INPUT
OUTPUT
USB
LV TRIGGER
ETHERNET
INFRARED
OUTPUT
INFRARED
Low Voltage Trigger — Via snap in/pull-out phoenix
connector. Input from low voltage (3-15V) trigger source.
Daisy chain LV Output to next amp's input.
INPUT
OUTPUT
+ - + -
LFE
L
+
L
R
INPUT
INPUT
OUTPUT
4Ω minimum
+ -
+ -
+ - + -
OUTPUT
R
SPEAKER INPUT
INPUT
OUTPUT
INPUT
OUTPUT
USB
LV TRIGGER
ETHERNET
INFRARED
LV TRIGGER
1

Advertisement

loading

Summary of Contents for Triad Platinum Series

  • Page 1 EQ profiles for all current Triad Sub models (some require 8Ω enclosures). A new FLAT selection has no 4Ω minimum model EQ and its Sub High Pass Filter is turned OFF. If you do not see your Triad subwoofer model contact INPUT...
  • Page 2 Triad’s current subwoofer line, The RackAmp 700 ensures peak USER 1 USER 2 USER 3 performance for each Triad model. The Flat setting can drive any The IR Remote supplied with this product contains a coin/button cell battery. 30 Hz to 300Hz, LFE MUTE Keep product and batteries away from children.

This manual is also suitable for:

Mini seriesPsir-bdl1Bsic-bdl2Bsic-bdl4Msic-bdl4Ssir-bdl1 ... Show all