Download Print this page

DBK HR User Instructions

Ptc finned resistor heater

Advertisement

Quick Links

User Instructions for PTC Finned Resistor Heater HR / HRI / HRKK
Product Description
Self-regulating PTC finned resistor heaters, based on PTC technology, to heat up air streams.
Operating voltage acc. to marking:
Ambient Temperature:
Humidity:
Installation
Installation by trained and qualified personnel only.
When connecting to a power supply, please make sure that the voltage corresponds to the electrical
information on the heater. The installation must comply with relevant local regulations, technical directions
and recognised standards.
All metal parts of the heater are live parts – don't touch when connected to power. The necessary protection
class, resp. clearance and creepage distances / minimum distances must be met and ensured by an
appropriate installation.
Touch protection towards the heater must be ensured by the way of installation.
Heater can be installed by using a mounting frame or the plastic end caps of the element.
The heater shall not be installed close to flammable materials.
The heater should be protected with a slow-blow fuse to avoid an accidental tripping of the fuse at cold start
of the heater.
When the heater is used in a dusty environment, an air filter should be installed in front of the heater to
avoid a deposit of fluff or dust in the aluminium fins of the element.
Operation
Electrical connection via 6,3 mm spade terminals.
Connection diagrams of the different heater types, see page 2 and 3.
Maintenance
Before cleaning or maintaining the heater, it must be fully disconnected from the net (with min. 3 mm
distance from the heater terminals to the connecting contacts).
The heater shall only be maintained and cleaned from qualified personnel.
The heater must be regularly tested on proper function.
A regular visual control with regard to contamination, foreign particles, loose parts or damage of the heater
shall be carried out by a technically qualified person.
The maintenance interval depends on the operating conditions but should not exceed 6 months.
Liquids or sharp articles shall never be used for cleaning purposes. Cleaning shall only be done with a brush
and/or vacuum cleaner.
There are no user-serviceable parts inside the heater. Disassembling the heater should not be attempted.
Warning
Never perform any works on the heater while it is energized.
All metal parts of the heater are live parts – don't touch when connected to power.
The heater will remain hot several minutes after switch off.
An operation with insufficient airflow leads to an impairment of the function and lifetime.
The finned heaters shall only be used to heat up an air stream.
An operation in a humid and/or aggressive environment is inadmissible.
Applied heater identification shall not be removed or changed.
Issue: 07/2010
220 – 240 V
100 – 120 V
230 – 400 V
Special Voltages (12 V ; 24 V ; 48 V ; 72 V)
- 25° C to + 65 ° C
85 % rH
1/3

Advertisement

loading

Summary of Contents for DBK HR

  • Page 1 User Instructions for PTC Finned Resistor Heater HR / HRI / HRKK Product Description Self-regulating PTC finned resistor heaters, based on PTC technology, to heat up air streams. Operating voltage acc. to marking: 220 – 240 V 100 – 120 V 230 –...
  • Page 2 Electrical Connection HR 01 / HR 08: HR 05 / HR 06: HR 03 / HR 02: HR 09 / HR 18: HR 15 / HR 04: HR 11 / HR 22: Issue: 07/2010...
  • Page 3 HR 20 / HR 40: HRI 20 / HRI 40: HRI 15 / HRI 04 HRI 05 / HRI 06: Issue: 07/2010...

This manual is also suitable for:

HriHrkk