User Instructions for PTC Finned Resistor Heater HR / HRI / HRKK
Product Description
Self-regulating PTC finned resistor heaters, based on PTC technology, to heat up air streams.
Operating voltage acc. to marking:
Ambient Temperature:
Humidity:
Installation
•
Installation by trained and qualified personnel only.
•
When connecting to a power supply, please make sure that the voltage corresponds to the electrical
information on the heater. The installation must comply with relevant local regulations, technical directions
and recognised standards.
•
All metal parts of the heater are live parts – don't touch when connected to power. The necessary protection
class, resp. clearance and creepage distances / minimum distances must be met and ensured by an
appropriate installation.
•
Touch protection towards the heater must be ensured by the way of installation.
•
Heater can be installed by using a mounting frame or the plastic end caps of the element.
•
The heater shall not be installed close to flammable materials.
•
The heater should be protected with a slow-blow fuse to avoid an accidental tripping of the fuse at cold start
of the heater.
•
When the heater is used in a dusty environment, an air filter should be installed in front of the heater to
avoid a deposit of fluff or dust in the aluminium fins of the element.
Operation
Electrical connection via 6,3 mm spade terminals.
Connection diagrams of the different heater types, see page 2 and 3.
Maintenance
•
Before cleaning or maintaining the heater, it must be fully disconnected from the net (with min. 3 mm
distance from the heater terminals to the connecting contacts).
•
The heater shall only be maintained and cleaned from qualified personnel.
•
The heater must be regularly tested on proper function.
•
A regular visual control with regard to contamination, foreign particles, loose parts or damage of the heater
shall be carried out by a technically qualified person.
•
The maintenance interval depends on the operating conditions but should not exceed 6 months.
•
Liquids or sharp articles shall never be used for cleaning purposes. Cleaning shall only be done with a brush
and/or vacuum cleaner.
•
There are no user-serviceable parts inside the heater. Disassembling the heater should not be attempted.
Warning
•
Never perform any works on the heater while it is energized.
•
All metal parts of the heater are live parts – don't touch when connected to power.
•
The heater will remain hot several minutes after switch off.
•
An operation with insufficient airflow leads to an impairment of the function and lifetime.
•
The finned heaters shall only be used to heat up an air stream.
•
An operation in a humid and/or aggressive environment is inadmissible.
•
Applied heater identification shall not be removed or changed.
Issue: 07/2010
220 – 240 V
100 – 120 V
230 – 400 V
Special Voltages (12 V ; 24 V ; 48 V ; 72 V)
- 25° C to + 65 ° C
85 % rH
1/3