Identiv PRIMIS FR-50-40-E Installation Manual

Relay bridge elevator control

Advertisement

Quick Links

Primis Relay Bridge
Installation Guide
PART NUMBERS
PHYSICAL SPECIFICATIONS
Length
Width
Height
Weight
Max Readers
Max Input
Max Output
SUMMARIZED LEVELS OF
ACCESS CONTROL COMPONENTS
Destructive Attack
Line Security
Endurance
Standby Power
Single Point Locking
INSTALLATION REQUIREMENTS
Primis Bridges should only be installed in dry, non-condensing
environments. The ambient temperature of the environment should
range between -40°C and 50°C.
Primis Encryption Bridges should only be mounted to non-conductive
surfaces. Incorrect mounting may short-circuit the electronics, which will
cause it to malfunction.
DC power, reader, and output device wires should be between 16-28
AWG. They should also be stripped 5.5mm to sufficiently fit the terminal
blocks and ensure that they do not come in contact with each other.
Elevator Control
FR-50-40-E, FR-50-40-EL
277 mm (10.91 in.)
165 mm (6.50 in.)
24 mm (0.94 in.)
564 g (19.89 oz.)
2
(each reader requires a FR-50-40-W485 adapter)
0
24
Electrical: UL294 and UL294B
EMI Radiation: FCC Part 15 Class B
Level I
Level I
Level I
Level I
Level I
identiv.com
sales@identiv.com
READER INSTALLATION REQUIREMENTS
The RS-485 input on the FR-50-40-E is intended for use in elevator cabs.
Two wire shielded cable running inside the travelling cable to the
elevator cab is connected to the RS-485 inputs on the FR-50-40-E Primis
Bridge and then connected to a FR-50-40-W485 (Wiegand to 485
adapter) in the cab.
A Wiegand output reader can then be connected to the inputs on the
FR-50-40-W485 adapter. Up to two reader adapters can be connected to
the RS-485 inputs on the FR-50-40-E.
The shield wire should only be connected at the RS-485 input on
the FR-50-40-E.
INSTALLATION PROCEDURE
1.
Wire any output devices to the Relay Outputs shown on the wiring
reference on the back.
2.
Supply power to the Primis Bridge using 12 - 16 Vdc & 1500
mA (1500 mA internal; ~60.4 mA per relay) DC power connected
directly to the Power In terminal on the Primis Bridge.
3.
Connect a Cat5e or Cat6 cable from any port on an Ethernet
switch to the RJ-45 connector on the Primis Bridge. Ensure
that the length of the cable between the switch to the Primis
Bridge is 100m or less. Greater lengths can be achieved by adding
switches or repeaters every 100m.
4.
To configure and add the Primis Bridge to a MESH/Primis
Server, refer to the MESH/Primis Solution Guide manual. the
RJ-45 connector on the Primis Bridge. Note: Ethernet only
supports a maximum cable length of 100 m.
the Primis Bridge circuit board indicates
that the bridge is powered but not
connected to a server.
+1 888-809-8880
FR-50-24-E
A solid green "Ready" LED light indicates
that the Primis Bridge has established a
connection to the server and is ready to use.