Download Print this page

Safran NetClock/NENA Option Kit Manual

Netclock/nena breakout cable for securesync 2400 model

Advertisement

Quick Links

NetClock/NENA Breakout Cable
Part Number: 2400-5000-0705
Revision: 2
ELECTRONICS & DEFENSE
For SecureSync 2400 Model
Product Option Guide
Page 1 of 7
30 August 2023

Advertisement

loading

Summary of Contents for Safran NetClock/NENA Option Kit

  • Page 1 ELECTRONICS & DEFENSE NetClock/NENA Breakout Cable For SecureSync 2400 Model Product Option Guide Part Number: 2400-5000-0705 Page 1 of 7 Revision: 2 30 August 2023...
  • Page 2: Installation

    NetClock 9483 NENA-Compliant Master Clock interfaces. The NetClock/NENA Option Kit uses the 15-pin multi-I/O connector (found on the main board of the unit), and the 1204- 0F Alarm Relay option card, to connect to the NetClock/NENA Breakout Cable. This cable provides the same three output interfaces as found on the NetClock 9483: BNC IRIG Out, RS-232 on DB9, and RS-485 and Alarm Relay on a shared terminal block, allowing users to swap in the 2400 system with seamless integration to end devices.
  • Page 3 Log on to the Web UI to further configure the Pin Layout. Navigate to MANAGEMENT > Network > Pin Layout. From here, you can either: Upload a Pin Layout configuration: Download the preset pin layout configuration file here: https://safran-navigation-timing.com/document/securesync-2400-netclock-nena-breakout-cable- pinout/ In the Actions panel of the Pin Layout page, select Upload Layout and upload the netclockcablepins.json file.
  • Page 4 SecureSync 2400 NetClock Option Guide, Rev 2 Click on the plus sign in the upper right corner, and ADD pins 3, 13, & 8 to ATC_OUT | RS485 (as in the following figure) and click Submit. Note: If your setup requires an IRIG AM output rather than DCLS, you will also need to ADD pins 6 & 7 to IRIG_OUT | RS485 to change the signal.
  • Page 5 SecureSync 2400 NetClock Option Guide, Rev 2 Additional Web UI configuration may be necessary based on your application of the inputs and outputs. You can select each output to change specifications (on your IRIG or ASCII signals, for instance). See the following image for reference.
  • Page 6 No power applied to SecureSync Open Short Alarm Relay Power Source More information on standard unit behavior or any other feature or function of the SecureSync 2400 can be found in the user manual at https://safran-navigation-timing.com/manuals/ Page 6 of 7...
  • Page 7 Information furnished by Safran is believed to be accurate and reliable. However, no responsibility is assumed by Safran for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Safran reserves the right to make changes without further notice to any products herein.

This manual is also suitable for:

2400-0000-0705Ca08r-0000-0010