Download Print this page

Advertisement

Quick Links

 
Instructions
 
SAFETY PRECAUTIONS 
NEVER use this product underwater without receiving TRAINING and CERTIFICATION in the technique of SCUBA diving from 
a recognized certification agency. Use of this equipment by a person who is not certified by a recognized agency shall 
render all warranties, express or implied, null and void. Use of underwater breathing devices by uncertified or untrained 
persons is dangerous and can result in severe injury or death.  
EasyDive is recommended for depths less than 30 feet. 
NEVER dive with a system that shows signs of damage, leakage or substandard performance.  
NEVER OVERFILL the system above 3000 psi, the air pressure stamped on the cylinder. ONLY use purified, dry compressed 
breathing air when refilling cylinder.  
DO NOT fill or use the system if it has been exposed to extreme heat exceeding 250°F, or open flame. Instead, discharge the 
cylinder completely and return it to an Authorized Dealer for inspection and possible hydrostatic testing. 
DO NOT use the regulator first stage as a carry handle when lifting the system as this can damage the regulator.
NEVER breathe completely empty underwater.  Water will enter inner stages of the regulator and may result in internal 
corrosion and require service. ALWAYS rise to the surface when the pressure gauge shows 500 psi.
ALWAYS dive with EasyDive full – less starting pressure means less time underwater.
NEVER leave the EasyDive standing upright. ALWAYS store lying down to prevent damage in case of tipping over.
NEVER rise up to the surface faster than the air bubbles.
NEVER hold your breath underwater. Breathe normally in and out during the whole dive.
 
GENERAL INFORMATION 
Practice using EasyDive in shallow water.   Practice switching between the SNORKEL & DIVE modes on the Snorkelator.  The 
amount of air you will receive will vary based on your lung capacity, depth, water temperature, exertion level, etc. 
EasyDive utilizes a dry snorkel, however some water may still enter the snorkel.  To clear the Snorkelator, tilt your head to 
the left and exhale sharply.  Repeat occasionally to keep clear.    
EasyDive is shipped empty – fill prior to use.    
The harness does NOT have built in buoyancy.   
The harness has pockets for optional weights, depending on your size & weight you may want to use them to help you dive 
underwater easier.  DO NOT overweight yourself. 
Cylinder and Harness are packed in a position ideal for shipping. Prior to use, loosen cylinder strap and lower cylinder in 
Harness so that 1
ALWAYS wear dive fins when using EasyDive. 
Some components may come in different colors/styles than shown online and in manual. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
st
 stage sits below top of Harness and retighten strap.    

Advertisement

loading

Summary of Contents for Easydive 700-003

  • Page 1   Instructions   SAFETY PRECAUTIONS   NEVER use this product underwater without receiving TRAINING and CERTIFICATION in the technique of SCUBA diving from  a recognized certification agency. Use of this equipment by a person who is not certified by a recognized agency shall  render all warranties, express or implied, null and void. Use of underwater breathing devices by uncertified or untrained  persons is dangerous and can result in severe injury or death.    EasyDive is recommended for depths less than 30 feet.   NEVER dive with a system that shows signs of damage, leakage or substandard performance.    NEVER OVERFILL the system above 3000 psi, the air pressure stamped on the cylinder. ONLY use purified, dry compressed  breathing air when refilling cylinder.    DO NOT fill or use the system if it has been exposed to extreme heat exceeding 250°F, or open flame. Instead, discharge the  cylinder completely and return it to an Authorized Dealer for inspection and possible hydrostatic testing.   DO NOT use the regulator first stage as a carry handle when lifting the system as this can damage the regulator.  NEVER breathe completely empty underwater.  Water will enter inner stages of the regulator and may result in internal  corrosion and require service. ALWAYS rise to the surface when the pressure gauge shows 500 psi.  ALWAYS dive with EasyDive full – less starting pressure means less time underwater.  NEVER leave the EasyDive standing upright. ALWAYS store lying down to prevent damage in case of tipping over.  NEVER rise up to the surface faster than the air bubbles.  NEVER hold your breath underwater. Breathe normally in and out during the whole dive.   GENERAL INFORMATION   Practice using EasyDive in shallow water.   Practice switching between the SNORKEL & DIVE modes on the Snorkelator.  The  amount of air you will receive will vary based on your lung capacity, depth, water temperature, exertion level, etc.   EasyDive utilizes a dry snorkel, however some water may still enter the snorkel.  To clear the Snorkelator, tilt your head to  the left and exhale sharply.  Repeat occasionally to keep clear.    ...
  • Page 2 Air Compressor Refill Adapter #920C    EasyDive Option 2 with separate Tank Valve includes:   19 cu.ft. DOT/TC marked cylinder   Custom Adjustable Harness   Tank Valve    Stage Regulator    Stage Regulator   Mini Pressure Gauge   Snorkelator (dry snorkel with patented valve to switch between DIVE & SNORKEL modes with a turn of the dial)   Carry Bag   Refill Adapter not necessary (fill at a dive shop same as standard SCUBA cylinder)      FILLING EASYDIVE OPTION 1 USING #920C AIR COMPRESSOR REFILL ADAPTER (For dive shop):  1. Attach #920C Adapter to Refill Port until finger tight ONLY.    Note: Apply small amount of food grade silicone grease to threads.  Note: Do not apply a wrench or otherwise overtighten.  2. Attach the yoke from the compressor to the Adapter and fill cylinder to 3000 psi.  3. When full, press the 2  stage Purge Button to bleed.  4. Check the Pressure Indicator.  If tank is full, the Dial Gauge will read 3000 psi.   5. Store EasyDive Kit with On/Off Knob in the OFF position until ready to dive.       ...
  • Page 3             Deluxe Filter              #930C             #910Q    Supplemental instructions for use with EasyDive (refer to Nomad User Instruction Manual for general operating  instructions):  1. For safety, always lay down cylinder on its side during filling.   2. Starting after Step 7 on page 5, attach Deluxe Filter to output hose as seen in picture.  Deluxe Filter end with the  male connector is the air inlet, and the other end with female quick disconnect is the air outlet.  The direction must  be correct.    3. Option 1:  Attach #930C Adapter to Refill Port on Spare Air, HEED & EasyDive (option 1) and attach to Deluxe Filter.  Option 2:  Attach #910Q Adapter to Tank Valve on EasyDive (option 2) and attach to Deluxe Filter.  4. Continue with Step 8 on page 5.    Notes & Precautions:     Deluxe Filter ‐ Ultra large air filter combines disc filters, activated carbon deodorization and desiccant.  Includes a  second filter tube along with replacement parts ‐ 10 filter discs, 4 o‐rings, & 5 burst discs.  This filter removes  impurities and residual moisture created during pumping process.  Deluxe Filter replacement: under normal  circumstances replace after being used 30 times or approximately 50 hours.  If the filter element is dirty, may be  replaced sooner.  Approximate service life is 1 year.    When replacing entire filter tube, the desiccant must be at the end of the male connector/air inlet.   Due to size of EasyDive, 1 EasyDive fill = 5 fills as stated in Nomad User Manual.    Time to fill – may take up to 60‐75 minutes.   ...
  • Page 4     BEFORE USING THE SNORKELATOR   1. Ensure that the Snorkelator is securely attached to the regulator.  2. Familiarize yourself with the operation of the Snorkelator & practice  turning the dial to each function several times:     Turn the dial to ‘SNORKEL’ when breathing off the snorkel (dial is  pointing toward the snorkel).             Silicone Gasket (black portion holds snorkel to regulator)     Turn the dial to ‘DIVE’ to breathe off the regulator (dial is pointing to  the regulator).      PRE‐DIVE CHECK  1. SLOWLY open the On/Off Knob counter‐clockwise to pressurize the regulator.    2. Check that there are no audible leaks.  NEVER DIVE with a regulator that shows any signs of leakage when  pressurized.  3. Visually check mini pressure gauge for needle to be within green zone.  4. Push Purge Button down and release.  Purge Button should move up and down freely.  To maintain full pressure  do not purge unnecessarily.  5. Affix your scuba diving mask to the Snorkelator clip.   6. Put vest on and adjust for a snug but comfortable fit.  Add soft weights to pockets (OPTIONAL).  7.
  • Page 5: Routine Care & Maintenance

        POST‐DIVE   NOTE:  Rinsing should occur as soon as possible after diving.  1. Remove unit from harness.  2. Before rinsing, check Pressure Gauge and make sure EasyDive is not empty (has some pressure) to prevent  entrance of moisture into the system.  Refill if necessary.  CAUTION:  If empty, water may have entered the regulator and cylinder and could lead to corrosion and/or  failure of the system.  Refer to Maintenance section.  3.  Soak the whole EasyDive unit (pressurized – Tank Valve ON) for at least 30 minutes in fresh water after each  use.  Rinse the 2  Stage and Snorkelator thoroughly to remove salt water and/or sand.  4. Turn the Snorkelator dial several times between DIVE and SNORKEL mode while rinsing in clean, fresh water.  5. Turn On/Off Knob on clockwise until it is completely closed.  6. Gently shake to dislodge any water and wipe dry with a clean towel.  7. Store EasyDive full or with some positive pressure to prevent contaminants from entering the cylinder.  Store in  a clean, dry environment with optimum temperatures of 50‐75°F for best product performance.  Avoid direct  sunlight, automobile trunks or other areas subject to temperature extremes.  NOTE:  Industry guidelines recommend replacing air in cylinders annually.         ROUTINE CARE & MAINTENANCE   For general cleaning, use a mild dish soap or Simple Green / biodegradable solution.   For sanitizing, use a commercially available regulator sanitizer available through a dive shop.   Keep the threads on the Refill Port (Combo model) clean and lubricated.  Use high‐quality, non‐toxic, food grade  silicone grease for best results.  CAUTION:  Never use a hydrocarbon based oil (i.e. household oil or motor oil).   If you notice damage, wear or suspect any leaking or missing parts, have EasyDive examined immediately.  WARNING:  Do not attempt to repair yourself.  Unauthorized repairs or tampering is hazardous. ...
  • Page 6: Statement Of Warranty

        FAQ  1. How do I get my EasyDive filled?  Take the EasyDive Option 1 along with the included refill adapter #920C to any  dive shop and they will fill it for you for a nominal fee.  EasyDive Option 2 uses a standard Scuba tank valve and  does not need #920C.  Dive shops have high pressure air compressors that pump clean breathing air.  EasyDive  comes with a DOT/TC marked cylinder and is not for use in EU countries.  2. Can I fill my EasyDive off a compressor purchased at a hardware store?  No, small compressors sold at hardware  stores only pump low pressure (about 125 psi) and do not filter the air so it is not breathing quality air.  EasyDive  has a high pressure 3000 psi cylinder.  3. Can I travel on a commercial airline with EasyDive?  TSA regulations state that a tank valve must be removed  from the cylinder, which in the case of EasyDive is professionally attached.  Therefore, it would take a  professional to remove and reassemble it.  For that reason we do not recommend flying with your EasyDive  system.  An alternative is to ship it (must be empty) to your vacation destination prior to your trip and then get  the EasyDive filled at your destination.  If you want to travel with a small air system, check out the Spare Air at  www.spareair.com which can be easily disassembled and taken on airlines.  4. Can I buy an extra cylinder?  EasyDive Option 1 Combo integrates the tank valve and 1  stage of the scuba  regulator into a very small and lightweight footprint that is unlike standard scuba set‐ups.  This means that you  cannot simply swap out the cylinder with another full cylinder.  EasyDive Option 2 has a separate tank valve and   stage regulator that allows you to purchase extra cylinders and simply swap them.    5. Do I need to be a certified diver to use EasyDive?  Yes, users should be scuba certified to understand the proper  procedures and understand the risks when using scuba equipment.  6. What depth can I use EasyDive kit to?  It is recommended to use EasyDive at less than 30 feet.      STATEMENT OF WARRANTY  Submersible Systems, Inc. guarantees to the original purchaser only, that the equipment purchased is free of defects in  material and/or workmanship under normal recreational scuba use for a period of one (1) year from the date of  purchase provided proper care and maintenance have been performed as prescribed by the owner’s manual.  Should  this product prove to be defective for any reason (other than those listed as limitations below) the product will be  serviced or replaced at Submersible Systems’ sole discretion at no charge (excluding shipping and handling).  Send to:  Submersible Systems, Inc.  7413 Slater Ave. ...

This manual is also suitable for:

700-001