Cornelius 230 VAC Installation Instructions

Voltage protector module kit on 230 vac, 50hz vantage post-mix dispensers

Advertisement

Quick Links

IMI CORNELIUS INC g One Cornelius Place g Anoka, MN 55303-6234
Telephone (800) 238-3600

INSTALLATION INSTRUCTIONS

VOLTAGE PROTECTOR MODULE KIT (P/N 440000401)
230 VAC, 50Hz VANTAGE POST-MIX DISPENSERS
Read and understand these instructions thoroughly before installing this Voltage Protector Module Kit. Purpose
of the Voltage Protector Module is to shut the Dispenser down should a too low or a too high power voltage con-
dition occur. Retain these instructions as part of your equipment manual.
LOOSE-SHIPPED PARTS
Note: Only qualified personnel should install this Kit.
Unpack and inspect kit. Make sure items are present and in good condition.
Item
No.
Part No.
1
XXXXXXXXX
Voltage Protector Module
2
560003334
Electrical Wire (brown)
3
560003335
Electrical Wire (black)
4
560003336
Electrical Wire (blue)
5
325282000
Screw, Hex Washer Hd; Self-Drilling, No. 8–18 Thread by 1/2-inch Long
KIT INSTALLATION
WARNING: To avoid possible fatal electrical shock or serious injury to Installer, make sure
Dispenser is disconneced from power source before attempting to install this kit.
1. Disconnect electrical power from the Dispenser
2. Remove screw securing the hood, then lift hood straight up off the Dispenser.
3. Remove two screws securing the electrical control box cover, then remove cover for access to the control
board.
NOTE: It may be necessary to relocate the transformer to make room for installation of the VOLTAGE
PROTECTOR MODULE (item 1) on the refrigeration deck as shown in Figure 1.
4. Remove two screws securing the transformer to the refrigeration deck. Discard the two transformer retain-
ing screws.
EIMI Cornelius Inc; 1998
Facsimile (612) 422-3246
ON
Table 1. Loose-Shipped Parts
Name
OBSOLETE
Qty
1
1
1
1
4
July 21, 1998
569000242

Advertisement

loading

Summary of Contents for Cornelius 230 VAC

  • Page 1: Installation Instructions

    IMI CORNELIUS INC g One Cornelius Place g Anoka, MN 55303-6234 Telephone (800) 238-3600 INSTALLATION INSTRUCTIONS VOLTAGE PROTECTOR MODULE KIT (P/N 440000401) 230 VAC, 50Hz VANTAGE POST-MIX DISPENSERS Read and understand these instructions thoroughly before installing this Voltage Protector Module Kit. Purpose of the Voltage Protector Module is to shut the Dispenser down should a too low or a too high power voltage con- dition occur.
  • Page 3 PRIMARY TERMINALS (HIGH VOLTAGE) SECONDARY TERMINALS (24 VAC) FIGURE 1. TRANSFORMER/VOLTAGE PROTECTOR MODULE LOCATION 5. Place the transformer and the VOLTAGE PROTECTOR MODULE (item 1) on the refrigeration deck in approximate locations as shown in Figure 1. 6. Using the transformer and the VOLTAGE PROTECTOR MODULE (item 1) as templates, mark their mount- ing holes locations on the refrigeration deck.
  • Page 4 ITEM 1 ITEM 3 GREEN INDICATOR LIGHT PIGGY BACK TERMINAL CONNECTION ITEM 4 YELLOW CONNECTOR INDICATOR ITEM 2 LIGHT FIGURE 2. WIRING DIAGRAM...

This manual is also suitable for:

50hz440000401